First results of the NEXT-100 detector using đŠđ« 𝟖𝟑 ​ m {}^{83\textrm{m}}\mathrm{Kr} decays NEXT collaboration

G. Martínez-Lema, C. Hervés Carrete, S. Torelli, M. Cid Laso, P. Våzquez Cabaleiro, B. Palmeiro, J.A. Hernando Morata, J.J. Gómez-Cadenas, C. Adams, H. Almazån, V. Álvarez, A.I. Aranburu, L. Arazi, I.J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C.D.R. Azevedo, K. Bailey, F. Ballester, J.E. Barcelo · 2025

Read First results of the NEXT-100 detector using đŠđ« 𝟖𝟑 ​ m {}^{83\textrm{m}}\mathrm{Kr} decays NEXT collaboration by G. MartĂ­nez-Lema, C. HervĂ©s Carrete, S. Torelli, M. Cid Laso, P. VĂĄzquez Cabaleiro, B. Palmeiro, J.A. Hernando Morata, J.J. GĂłmez-Cadenas, C. Adams, H. AlmazĂĄn, V. Álvarez, A.I. Aranburu, L. Arazi, I.J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C.D.R. Azevedo, K. Bailey, F. Ballester, J.E. Barcelo (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-01710.txt.

Introduction

The NEXT Collaboration reports first calibration results from NEXT-100. It is a high-pressure xenon gas detector in Spain's Canfranc underground lab. The detector hunts for neutrinoless double beta decay of xenon-136. Its design pairs fine energy resolution with a topological signature of the decay. Commissioning began in May 2024. Xenon running at 4 bar began that October.

Calibration used krypton-83m decays. Their point-like deposits map the response across the detector volume and track its stability over time. After the light response was evened out, the energy resolution reached about 4.4 percent of the peak width at 41.5 keV. In a fiducial region at working settings it improved to about 4.2 percent. Scaled up to the decay energy, the resolution nears 0.5 percent at the target energy. That is well below the 1 percent design target.

Catalog record

CREATORG. Martínez-Lema, C. Hervés Carrete, S. Torelli, M. Cid Laso, P. Våzquez Cabaleiro, B. Palmeiro, J.A. Hernando Morata, J.J. Gómez-Cadenas, C. Adams, H. Almazån, V. Álvarez, A.I. Aranburu, L. Arazi, I.J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C.D.R. Azevedo, K. Bailey, F. Ballester, J.E. Barcelo
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE38 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-01710

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

First results of the NEXT-100 detector using đŠđ« 𝟖𝟑 ​ m {}^{83\textrm{m}}\mathrm{Kr} decays NEXT collaboration G. MartĂ­nez-Lema, C. HervĂ©s Carrete, S. Torelli, M. Cid Laso, P. VĂĄzquez Cabaleiro, B. Palmeiro, J.A. Hernando Morata, J.J. GĂłmez-Cadenas, C. Adams, H. AlmazĂĄn, V. Álvarez, A.I. Aranburu, L. Arazi, I.J. Arnquist, F. Auria-Luna, S. Ayet, Y. Ayyad, C.D.R. Azevedo, K. Bailey, F. Ballester, J.E. Barcelon, M. del Barrio-Torregrosa, J.M. Benlloch-RodrĂ­guez, F.I.G.M. Borges, A. Brodolin, N. Byrnes, A. Castillo, E. Church, X. Cid, C.A.N. Conde, C. Cortes-Parra, F.P. CossĂ­o, R. Coupe, E. Dey, P. Dietz, C. Echevarria, M. Elorza, R. Esteve, R. Felkai, L.M.P. Fernandes, P. Ferrario, F.W. Foss, Z. Freixa, J. GarcĂ­a-Barrena, J.W.R. Grocott, R. Guenette, J. Hauptman, C.A.O. Henriques, V. Herrero, P. Herrero-GĂłmez, Y. Ifergan, B.J.P. Jones, F. Kellerer, L. Larizgoitia, A. Larumbe, P. Lebrun, F. Lopez, N. LĂłpez-March, R. Madigan, R.D.P. Mano, A. Marauri, A.P. Marques, J. MartĂ­n-Albo, A. MartĂ­nez, M. MartĂ­nez-Vara, R.L. Miller, K. Mistry, J. Molina-Canteras, F. Monrabal, C.M.B. Monteiro, F.J. Mora, K.E. Navarro, P. Novella, D.R. Nygren, E. Oblak, I. Osborne, J. Palacio, A. Para, I. Parmaksiz, A. Pazos, J. Pelegrin, M. PĂ©rez Maneiro, M. Querol, J. Renner, I. Rivilla, C. Rogero, L. Rogers, B. Romeo, C. Romo-Luque, E. Ruiz-ChĂłliz, P. Saharia, F.P. Santos, J.M.F. dos Santos, M. Seemann, I. Shomroni, A.L.M. Silva, P.A.O.C. Silva, A. SimĂłn, S.R. Soleti, M. Sorel, J. Soto-Oton, J.M.R. Teixeira, J.F. Toledo, C. TonnelĂ©, J. Torrent, S. Teruel-Pardo, A. Trettin, P.R.G. Valle, M. Vanga, J.F.C.A. Veloso, J.D. Villamil, L.M. Villar Padruno, J. Waiton, A. Yubero-Navarro Abstract The NEXT collaboration is investigating the double beta decay of Xe 136 {}^{136}\rm Xe using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio SubterrĂĄneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from Kr 83 ​ m {}^{83\textrm{m}}\mathrm{Kr} decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for Kr 83 ​ m {}^{83\textrm{m}}\mathrm{Kr} point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an E − 1 / 2 E^{-1/2} extrapolation to Q ÎČ â€‹ ÎČ Q_{\beta\beta} yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target. 1 Introduction Neutrinoless double beta decay ( \beta\beta 0\nu ) is a putative rare nuclear decay that violates lepton number conservation. An observation would unequivocally establish the Majorana nature of the neutrino. Currently, the most stringent constraints on the half-life of this process ( T_{1/2}^{0\nu} ) are set by the KamLAND-Zen experiment at 2.23\times 10^{26} yr (90% C.L.) for {}^{136}\rm Xe KamLAND-Zen:23 , and by the LEGEND-200 experiment at 1.9\times 10^{26} yr (90% C.L.) for {}^{76}\rm Ge LEGEND:2025jwu . NEXT is a \beta\beta 0\nu experiment searching for this decay in gaseous {}^{136}\rm Xe using a High Pressure Time Projection Chamber with ElectroLuminescent amplification (HPXeTPC-EL). After a series of prototypes DEMO1 ; DEMO2 ; DEMO3 ; DEMO4 , the NEXT Collaboration operated NEXT-White NEWDetector , a mid-scale HPXeTPC-EL holding \sim 5 kg of {}^{136}\rm Xe -enriched xenon at 10 bar hosted at the Laboratorio SubterrĂĄneo de Canfranc (LSC). With NEXT-White, the Collaboration provided a direct estimation of sub-percent FWHM energy resolution at Q_{\beta\beta} NEWEres1 ; NEWEres2 , demonstrated the topological discrimination between single- and double-electron tracks Kekic2021 ; NEWTrack1 ; NEWTrack2 , measured the main backgrounds of the experiment NEWBkg1 ; NEWBkg2 , obtained the first measurement of the half life of the two-neutrino mode of the decay using a novel technique NEW2nubb , and established a limit on T_{1/2}^{0\nu} NEW0nubb . Following the success of its predecessor, the Collaboration built NEXT-100, a {\sim}10\times larger apparatus (by volume) that began operations in 2024 NEXT:2025yqw . The detector was operated with depleted xenon at a pressure of 4 bar, while its nominal operation at high pressure (13.5 bar) is foreseen to begin in early 2026. Here we report the first results obtained during the calibration run with low-energy events in NEXT-100. Following a procedure similar to the one employed in NEXT-White NEWKR , {}^{83\textrm{m}}\mathrm{Kr} decays were used to characterize the detector in the active volume. This enabled the mapping of the light response as a function of (x,y,z) . The variations in (x,y) arise from a combination of the dependence of the light collection efficiency due to variations on the effective solid angle coverage, and from inhomogeneities in the electroluminescence (EL) field. Variations along the longitudinal coordinate ( z ) originate mainly from electron attachment. This method was also used to assess the performance of the detector at low energies with point-like events, and to monitor its stability over time, allowing for a continuous calibration of the detector during data-taking campaigns. These {}^{83\textrm{m}}\mathrm{Kr} calibrations allow for the homogenization of the detector response, which plays a pivotal role in the overall performance of the detector at high energies. The article is structured as follows. In Section 2 , we provide a brief description of the NEXT-100 detector. In Section 3 , we describe the data-taking campaign and the {}^{83\textrm{m}}\mathrm{Kr} calibration procedure, and present the analysis of the detector response in the active volume. In Section 4 , we analyze the detector stability over the calibration run. In Section 5 , we evaluate the energy resolution obtained for {}^{83\textrm{m}}\mathrm{Kr} deposits and its variation over the active volume. The results and conclusions are summarized in Section 6 . 2 The NEXT-100 detector NEXT-100 is a cylindrical HPXeTPC-EL instrumented with photosensor planes at each end of the chamber. On one end, the energy plane hosts photomultiplier tubes (PMTs), used to measure energy and the start time of the event. On the opposite side of the detector, the tracking plane features an array of silicon photomultipliers (SiPMs), used to extract topological information from the events. With an inner diameter of 98.3 cm, the detector volume is divided into three regions with different electric fields by three stainless steel meshes with hexagonal openings acting as cathode, gate and anode. The drift region , bounded by the cathode and the gate, is 118.7 cm long. The EL region adjacent to the drift region is a 0.97 cm long gap defined by the gate and the anode. The tracking plane is located 15 mm away from the anode. The space between the energy plane and the cathode defines the buffer region , a 24 cm long gap that prevents sparks between the cathode and the energy plane and suppresses the production of unwanted electroluminescence in this region. A scheme of the NEXT-100 detector is shown in Figure 1 ; a detailed description of the NEXT-100 detector can be found in NEXT:2025yqw . Figure 1: Schematic drawing of the NEXT-100 detector. Reproduced from NEXT:2025yqw .

Read the complete text