Improving Needle Penetration via Precise Rotational Insertion Using Iterative Learning Control

Yasamin Foroutani, Yasamin Mousavi-Motlagh, Aya Barzelay, Tsu-Chin Tsao · 2025

Read Improving Needle Penetration via Precise Rotational Insertion Using Iterative Learning Control by Yasamin Foroutani, Yasamin Mousavi-Motlagh, Aya Barzelay, Tsu-Chin Tsao (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-01256.txt.

Introduction

Yasamin Foroutani and colleagues improve how a surgical robot inserts a needle into the eye. Precise tool paths are undermined by poor alignment, hidden dynamics, and actuator errors. In their setup, a four degree of freedom robot arm must rotate the needle during insertion, and misalignment of the fourth joint makes plain rotation unsteady.

Their plan is iterative learning control: the robot repeats the insertion, measures the position error each time from optical coherence tomography volume scans, and adjusts the joint commands for the next attempt. A careful motion calibration comes first. Tested on subretinal injection in ex vivo pig eyes, the learned turning path reached higher success in tissue piercing and injection than straight insertion. The authors say the result may transfer to other precision tasks of this kind.

Catalog record

CREATORYasamin Foroutani, Yasamin Mousavi-Motlagh, Aya Barzelay, Tsu-Chin Tsao
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE38 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-01256

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Improving Needle Penetration via Precise Rotational Insertion Using Iterative Learning Control Yasamin Foroutani, Yasamin Mousavi-Motlagh, Aya Barzelay, Tsu-Chin Tsao Abstract Achieving precise control of robotic tool paths is often challenged by inherent system misalignments, unmodeled dynamics, and actuation inaccuracies. This work introduces an Iterative Learning Control (ILC) strategy to enable precise rotational insertion of a tool during robotic surgery, improving penetration efficacy and safety compared to straight insertion tested in subretinal injection. A 4 degree of freedom (DOF) robot manipulator is used, where misalignment of the fourth joint complicates the simple application of needle rotation, motivating an ILC approach that iteratively adjusts joint commands based on positional feedback. The process begins with calibrating the forward kinematics for the chosen surgical tool to achieve higher accuracy, followed by successive ILC iterations guided by Optical Coherence Tomography (OCT) volume scans to measure the error and refine control inputs. Experimental results, tested on subretinal injection tasks on ex vivo pig eyes, show that the optimized trajectory resulted in higher success rates in tissue penetration and subretinal injection compared to straight insertion, demonstrating the effectiveness of ILC in overcoming misalignment challenges. This approach offers potential applications for other high precision robot tasks requiring controlled insertions as well. I Introduction Fig. 1 : System overview showing the experimental setup, using Thorlabs OCT, IRISS robot, and an open sky pig eye to perform injection. Accurate and precise control of movement is fundamental to many scientific fields [ 1 ] , but it becomes even more critical in surgical applications where even minor deviations can significantly impact outcomes. Surgical procedures often demand sub-millimeter accuracy, especially in areas involving delicate tissues and confined spaces, such as ophthalmology. However, consistently achieving this level of precision can be challenging due to the inherent limitations of human motor skills, such as involuntary tremors and fatigue [ 2 ] . These limitations are amplified in intraocular microsurgery, requiring not only steady hands, but also enhanced sensory feedback and hand-eye coordination. As a result, there has been increasing interest in augmenting surgical precision through the use of robotic systems, which can assist surgeons and automate difficult tasks, leading to improved accuracy and stability compared to manual techniques [ 3 ] . One critical surgical maneuver is precise needle insertion through sensitive tissues, where maintaining exact trajectory control is paramount. Consistent penetration of the target tissue using straightforward linear insertion alone is challenging due to variations in tissue resistance, elasticity differences, changes in needle sharpness, and needle deflection [ 4 ] . This frequently leads to tissue deformation without penetration, or sudden bounce back of the tissue following needle insertion, increasing risks of damage and overshoot [ 5 ] . Studies indicate that bidirectional rotational motion during needle insertion can significantly reduce contact forces and improve penetration efficacy [ 6 , 7 ] , while reducing needle deflection and improving precision [ 8 , 9 ] . However, manually achieving such precise rotational motions is nearly impossible due to human motor limitations. As such, robotic systems are crucial for the development of such a surgical strategy. Despite the advantages robots bring to surgery, achieving precise rotational control remains problematic. Robotic systems are susceptible to system misalignments [ 10 , 11 , 12 , 13 , 14 ] , unmodeled dynamics [ 15 , 16 ] , and actuation inaccuracies [ 17 , 18 ] , all of which can hinder precise tasks such as needle insertion. These issues can lead to unintentional tooltip displacements, introducing disturbances that are difficult to model and compensate for in real time [ 7 , 19 ] . Such limitations necessitate advanced control strategies to refine robot motion and maintain surgical precision throughout the operation. To address the challenges of achieving precise robot control, various advanced control strategies have been developed. Traditional PID controllers remain a foundational approach in robotics due to their simplicity and ease of implementation. They fall short, however, in situations where kinematic and dynamic errors are present. Classical computed torque or inverse dynamics methods address some of these issues by correcting for nonlinearities [ 20 ] . They still depend heavily on accurate dynamic models of the robot, though, and performance degrades in the presence of uncertainties. Adaptive control strategies build on this approach by continuously adjusting control parameters to correct for the effects of system variations and model uncertainties. Such techniques ensure the system can compensate for changing dynamics during operation [ 21 , 22 ] . These methods, while robust, can introduce complex adaptation laws that require careful tuning and significant computational resources, making implementation in real-time surgical environments challenging. A common challenge shared by all the mentioned feedback approaches is the need for rigorous stability analysis and potential redesigns of the controller to account for changing dynamics and kinematic uncertainties. This often complicates integration into existing platforms or new applications. In contrast, feedforward control methods offer an attractive alternative. By proactively predicting and compensating for errors, feedforward controllers minimize the need for real-time feedback. This makes them simple to integrate, leading to enhanced performance without altering the baseline low-level controller, and has motivated complementary approaches that tune feedforward cost functions from offline optimal solutions [ 23 ] . For repetitive tasks where consistent trajectories are crucial, Iterative Learning Control (ILC) is a particularly effective feedforward strategy. ILC refines the control inputs by learning from previous executions, iteratively reducing errors over successive trials. This method has successfully been implemented in industrial applications such as machining [ 24 ] , additive manufacturing [ 25 ] , flatbed printers [ 26 ] , wafer stages [ 27 ] , and industrial robot arms [ 28 ] . The iterative nature of ILC makes it an ideal solution for surgical procedures such as needle insertions. It can iteratively correct for kinematic errors and misalignments, while also compensating for dynamic variations in the robot. Unlike traditional methods, ILC achieves this without the need for continuous recalculation or detailed dynamic modeling, making it an efficient and robust solution for enhancing accuracy in repetitive surgical procedures. When the dynamic model of the system is accurately known, model-based ILC approaches can be used, such as in [ 29 , 30 , 31 , 32 , 33 ] . However, in the absence of such models, data-driven ILC, using data from previous trials, is used for learning [ 34 ] . This work aims to implement precise rotational needle insertion using a dual-loop iterative learning control method, similar to that proposed by [ 28 ] , to enhance injection precision and repeatability in ophthalmic surgery. In this approach, the first loop focuses on minimizing end-effector deviations by iteratively adjusting the surgical tool’s trajectory, while the second loop compensates for motor dynamics to achieve accurate trajectory tracking. A key advantage of utilizing this ILC strategy is its data-driven nature, leveraging 3D Optical Coherence Tomography (OCT) imaging feedback to measure positional errors at each iteration. By continuously updating the trajectory based on this visual information, the system effectively corrects for unmodeled dynamics and tool misalignments without requiring explicit recalculation of robot parameters. This two-step architecture not only improves rotational insertion accuracy over successive trials but also provides a scalable and adaptable pipeline applicable

Read the complete text