Characterising Atomic-Scale Surface Disorder on 2D Materials Using Neutral Atoms

Chenyang Zhao, Sam M. Lambrick, Ke Wang, Shaoliang Guan, Aleksandar Radić, David J. Ward, Andrew P. Jardine, Boyao Liu · 2025

Read Characterising Atomic-Scale Surface Disorder on 2D Materials Using Neutral Atoms by Chenyang Zhao, Sam M. Lambrick, Ke Wang, Shaoliang Guan, Aleksandar Radić, David J. Ward, Andrew P. Jardine, Boyao Liu (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-00770.txt.

Introduction

Chenyang Zhao and seven co-authors inspect the surfaces of two-dimensional materials with a microscope that breathes helium. Molybdenum disulfide and its cousins promise electronics and sensors, but device performance hinges on surface cleanness at the atomic scale. Even surfaces prepared in ultra-high vacuum collect trace contamination, and conventional tools barely notice submonolayer dirt. Scanning helium microscopy offers non-destructive, ultra-sensitive eyes.

Minute amounts of stray carbon, the measurements reveal, disorder the surface enough to erase helium diffraction entirely. Tracking helium reflectivity over time quantifies how order decays in different regions: flat areas succumb faster than regions near edges. Surface order in these materials is fragile even under vacuum, the team concludes, and their microscope gives wafer-scale quality checks a new, gentle instrument.

Catalog record

CREATORChenyang Zhao, Sam M. Lambrick, Ke Wang, Shaoliang Guan, Aleksandar Radić, David J. Ward, Andrew P. Jardine, Boyao Liu
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE35 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-00770

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Characterising Atomic-Scale Surface Disorder on 2D Materials Using Neutral Atoms Chenyang Zhao, Sam M. Lambrick, Ke Wang, Shaoliang Guan, Aleksandar Radić, David J. Ward, Andrew P. Jardine, Boyao Liu Abstract \mciteErrorOnUnknownfalse † † affiliation: Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0US, United Kingdom † † email: [email protected] † † affiliation: Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0US, United Kingdom † † affiliation: ISIS Facility, Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire OX11 0QX, United Kingdom † † email: [email protected] † † email: [email protected] † † email: [email protected] † † affiliation: Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0US, United Kingdom Two-dimensional (2D) transition metal dichalcogenides (TMDs), such as MoS 2 , have the potential to be widely used in electronic devices and sensors due to their high carrier mobility and tunable band structure. In 2D TMD devices, surface and interface cleanness can critically impact the performance and reproducibility. Even sample surfaces prepared under ultra-high vacuum (UHV) can be contaminated, causing disorder. On such samples, trace levels of submonolayer contamination remain largely overlooked, and conventional surface characterisation techniques have limited capability in detecting such adsorbates. Here, we apply scanning helium microscopy (SHeM), a non-destructive and ultra-sensitive technique, to investigate the surface cleanness of 2D MoS 2 . Our measurements reveal that even minute amounts of adventitious carbon induce atomic-scale disorder across MoS 2 surfaces, leading to the disappearance of helium diffraction. By tracking helium reflectivity over time, we quantify the decay of surface order across different microscopic regions and find that flat areas are more susceptible to contamination than regions near edges. These findings highlight the fragility of surface order in 2D materials, even under UHV, and establish SHeM as a powerful tool for non-damaging microscopic 2D material cleanness characterisation. The approach offers a new route to wafer-scale characterisation of 2D material quality. 1 Introduction Two-dimensional transition metal dichalcogenides (2D TMDs), such as molybdenum disulfide (MoS 2 ), have emerged as semiconductor materials for next-generation electronic and optoelectronic devices due to their atomically thin structure, tunable bandgap, and high carrier mobility Manzeli et al. 2017 . The properties of TMDs are highly sensitive to changes to surface conditions. Specifically, surface contamination consisting of chemisorbed and physisorbed species has an effect on the electronic properties of such 2D materials Kretinin et al. 2014 ; Hou et al. 2023 ; Park et al. 2023 , and is known to affect the performance of nanoscale devices Jariwala et al. 2013 ; Tongay et al. 2013 . The influence of surface contaminants is significantly more acute than for traditional silicon semiconductors, where the electronic properties are determined by the bulk material. For 2D materials, contamination layers can be as thick as the semiconductor itself and it is often the reduced dimensionality that provides the advantageous electronic properties of these materials. Thus surface cleanness characterisation has become a critical concern in both fundamental studies and practical device applications Wu et al. 2024 ; Wang and Chhowalla 2022 ; Illarionov et al. 2020 ; Dong et al. 2024 ; Sovizi et al. 2023 ; Wu et al. 2022 . However, weakly bound adsorbates, often referred to as being physisorbed, have proven difficult to identify and measure, especially on wafer scale systems. Even if devices are to be encapsulated, the presence of contamination between layers during fabrication remains an important issue. Indeed, on the wafer scale contamination is a greater concern than on the nanoscale, as the “self-healing” processes Dong et al. 2024 ; Haigh et al. 2012 ; Rooney et al. 2017 ; Kretinin et al. 2014 observed with devices constructed by mechanical exfoliation may not be applicable over large areas. To address the challenges of detecting weakly bound surface contaminants, we focus on adventitious carbon, a ubiquitous contaminant even under UHV conditions Grey et al. 2024 ; Greczynski 2024 ; Barr and Seal 1995 ; Greczynski and Hultman 2020 , on MoS 2 , a prototypical 2D semiconductor actively being utilised in device applications Manzeli et al. 2017 ; Guros et al. 2019 ; Chen et al. 2021 . We introduce a novel approach for characterising weakly bound surface adsorbates over large sample areas by applying scanning helium microscopy (SHeM) Barr et al. 2014 ; Witham and Sánchez 2011 ; Palau et al. 2023 ; Zhao et al. 2025 , a technique which uses low energy neutral helium atoms to provide exceptional sensitivity to surface contamination. Adventitious carbon, as a predominantly aliphatic hydrocarbon-based contaminant with minor oxygen functionalities Biesinger 2022 ; Grey et al. 2024 , significantly affects the chemical, structural, and electronic properties of 2D materials. For example, it modifies surface chemistry and energetics, causing increased hydrophobicity Kozbial et al. 2015 , frictional anisotropy Pálinkás et al. 2022 , and altered work function or contact properties Chen et al. 2021 ; Kim et al. 2024 . In the electronic regime, adventitious carbon introduces electronic disorder and charge inhomogeneity Kretinin et al. 2014 ; Hou et al. 2023 , shifts doping behaviour Hou et al. 2023 ; Park et al. 2023 , and contributes to mobility degradation in devices Kretinin et al. 2014 ; Chen et al. 2021 ; Guros et al. 2019 . These impacts extend further to interface integrity and device reproducibility. Even trace adventitious carbon residues can disturb interfacial crystallinity Bayer et al. 2018 and contribute to performance variability across nominally identical devices Guros et al. 2019 . In some cases, adventitious carbon can act as a reactive site for oxidation and etching Park et al. 2020 . Moreover, its spectral complexity and variability interfere with spectroscopic interpretation Barr and Seal 1995 ; Marinov et al. 2023 . While annealing, sputtering or tip-based cleaning can effectively remove adventitious carbon Guros et al. 2019 ; Bayer et al. 2018 ; Kim et al. 2024 ; Buitrago et al. 2024 ; Chen et al. 2021 , its re-adsorption under UHV conditions is not well characterised and has attracted limited attention in the 2D materials community. Previous characterisation of contaminants on 2D/van der Waals (vdW) materials has generally followed two directions. First, X-ray photoelectron spectroscopy (XPS) has been used to identify the chemical composition of the contamination Greczynski and Hultman 2020 ; Addou et al. 2015 . However, traditional XPS does not possess spatial resolution, and selected-area XPS Bozzini et al. 2019 has reduced sensitivity, which is crucial for thin layers of contaminant. Second, the morphology of the contamination has been explored with scanning tunnelling microscopy (STM) Pálinkás et al. 2022 and transmission electron microscopy (TEM) Park et al. 2020 . These two approaches represent extremes in the length scale, with XPS generally sensitive to macroscopic areas, while TEM and STM are restricted to very small sample areas. Neither current approach represents a practical method of testing surface cleanliness over both larger areas (wafer scale) and with spatial resolution. In addition, both TEM and XPS use high energy probes, which have sufficient energy to cause desorption as well as changes/damage to the sample Jain et al. 2024 ; Krishna and Philip 2022 . STM is generally considered non-damaging, however, even then tip-induced desorption is a known phenomenon Møller et al. 2017 . Addressing the characterisation gap

Read the complete text