Quantifying the Full Damage Profile of Focused Ion Beams via 4D-STEM Precession Electron Diffraction and PSNR Metrics

M.G. Masteghin · 2025

Read Quantifying the Full Damage Profile of Focused Ion Beams via 4D-STEM Precession Electron Diffraction and PSNR Metrics by M.G. Masteghin (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2511-00320.txt.

Introduction

M G Masteghin and six co-authors map the full damage left by focused ion beams, fine tools used to cut and build at the nanoscale. Most checks measure only the beam's bright core, where most ions land. The faint tail matters for precise jobs like placing impurities in a chip, yet it is usually missed. The team uses an advanced electron microscopy method that records diffraction at every scan point.

By comparing patterns from known exposures with spots dosed by a gallium beam, they detect damage at extremely low levels. A noise-based score proved more sensitive and robust than standard dark-field imaging. The fuller profile helps users judge beam performance beyond simple sharpness and tailor settings for delicate work.

Catalog record

CREATORM.G. Masteghin
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE54 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2511-00320

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Quantifying the Full Damage Profile of Focused Ion Beams via 4D-STEM Precession Electron Diffraction and PSNR Metrics M.G. Masteghin Abstract Focused ion beams (FIBs) are widely used in nanofabrication for applications such as circuit repair, ultra-thin lamella preparation, strain engineering, and quantum device prototyping. Although the lateral spread of the ion beam is often overlooked, it becomes critical in precision tasks such as impurity placement in host substrates, where accurate knowledge of the ion-matter interaction profile is essential. Existing techniques typically characterise only the beam core, where most ions land, thus underestimating the full extent of the point spread function (PSF). In this work, we use four-dimensional scanning transmission electron microscopy (4D-STEM) to resolve the ion beam tail at defect densities equivalent to < < 0.1 ions nm -2 . Convergent beam electron diffraction (CBED) patterns were collected in calibration regions with known ion fluence and compared to patterns acquired around static dwell spots exposed to a 30 keV Ga + beam for 1–10 s. Cross-correlation using peak signal-to-noise ratio (PSNR) revealed that 4D-STEM datasets are ultra-sensitive for defect quantification and more robust against scanning artefacts than conventional dark-field imaging. This approach is complementary to image resolution methods enabling a comprehensive profiling of ion-induced damage even at low-dose regimes, offering a more accurate representation of FIB performance and supporting application tailoring beyond the conventional resolution metrics focused solely on the beam core. 1 1 footnotetext: Corresponding author: [email protected] I Introduction Focused ion beam (FIB) systems are indispensable tools in nanofabrication, offering high spatial resolution for ion implantation McCallum2012 ; Adshead2023 ; Masteghin2024 , milling Mayer2007 , and other material modifications such as strain engineering Masteghin2021 or composite deposition Masteghin2018 . In advanced applications such as quantum devices fabrication, where atomic-scale precision is paramount Kane1998 , understanding the full spatial extent of ion-induced damage becomes crucial. This is particularly important in the low-dose regime, where even very limited ion exposure can degrade the coherence properties of quantum bits (qubits) Masteghin2024b ; Holmes2024 or alter the optical properties of quantum dots Lee2011 . Accurate characterisation of ion beam damage profiles not only could reveal intrinsic limitations of FIB techniques but also provide a foundation for refining microscope optics, developing mitigation strategies, and tailoring tool performance to meet the stringent requirements of emerging quantum technologies Masteghin2024 ; Schofield2025 . Drezner et al. Drezner2017 discussed several techniques to measure ion beam profile and their limitations, such as scanning across heterostructures, knife-edge methods, and resist-based imaging. In the heterostructure approach, the beam is scanned across a material interface (e.g. Si/SiGe), and the resulting contrast (or grey levels) is used to infer the beam shape. This approach is discussed below. While this method provides good lateral resolution, it requires complex sample preparation and is sensitive to interface quality. Knife-edge techniques involve scanning the beam across a sharp boundary (e.g. a metal edge or a patterned mask) and analysing the resulting signal gradient. These methods are straightforward, but often suffer from convolution effects and limited sensitivity to low-dose tails. Resist-based imaging, where ion exposure modifies a resist layer, offers high contrast but lacks quantitative accuracy and is limited by resist sensitivity thresholds. Hence, most techniques are only accurate for determination of the full width at half maximum of the ion beam “core”, or what we will refer to here as “imaging resolution”. To overcome these limitations, we present a novel application of four-dimensional scanning transmission electron microscopy (4D-STEM). We propose the use of 4D-STEM to map ion beam damage with high sensitivity and spatial resolution in the low-dose regime. In 4D-STEM, a full convergent beam electron diffraction (CBED) pattern is recorded at each scan position, enabling detailed analysis of the local crystal structure. By comparing CBED patterns from pristine and Ga + -implanted regions (30 keV, doses from 0.09 to 5 ions nm -2 ), we extract peak signal-to-noise ratio (PSNR) values as a quantitative metric of structural degradation. These values are then mapped across a 30 nm thick silicon crystal irradiated at a single point for varying durations, and the pixels position for the surrounding area are converted to local ion densities using a calibration curve derived from the known-dose regions. This method is uniquely suited to probe the beam tail: while it is insensitive to the highly damaged beam core, where diffraction contrast is lost, it is exceptionally sensitive to subtle structural changes in the low-dose periphery. This makes it ideal for applications where understanding the spatial extent of minimal damage is crucial, such as in deterministic ion implantation for quantum technologies. Recent advances have positioned 4D-STEM as a powerful and increasingly popular technique for assessing crystal quality. It has been used to map strain Mahr2021 , identify defects Fang2019 , and reconstruct phase information with atomic resolution Chen2021 . Its ability to capture rich diffraction data at each scan point enables new insights into local structure and disorder, making it a valuable tool in both fundamental research and applied materials science. Our work extends the application portfolio for 4D-STEM, including the use of PSNR-based analysis for quantitative ion beam point spread function profiling. This approach complements existing techniques and provides a robust, high-resolution method for mapping ion beam tails, an area where traditional methods often fall short. Materials and Methods The 30 nm thick single-crystal Si membranes were commercially manufactured by Silson Ltd. The window edges and diagonals are oriented along the <110> and <100> directions, respectively, with (001) surface plane. Details on how Si membranes can be produced can be found in Palik1988 ; vu1996 ; zubel2000 . Singly charged gallium ions ( Ga^{+} ) with an energy of 30 keV were implanted using a dual-beam focused ion beam microscope and scanning electron microscope (FIB-SEM, FEI Nova Nanolab). The gallium ion current was measured before and after implantation using a Faraday cup and determined to be 7.5 pA on both readings and, therefore, was assumed constant throughout the implantation. The conventional resolution test was performed by imaging a gold on carbon sample, capturing an image of 1024\times 1024 pixels 2 with a dwell time of 30\text{\,}\mathrm{\SIUnitSymbolMicro s} . For dark-field scanning transmission electron microscopy (STEM) imaging, a line of milled spots in a 30 nm thick Si membrane was created by scanning the ion beam with a pitch of 5000 nm and dwell times exponentially increasing from 0.08 ms to 500 ms. For the 4D-STEM measurements, the patterns consisted of two main components, the calibration squares and the milled spots. The 28 calibration squares had dimensions equal to 2500\times 2500 nm 2 with a centre-to-centre spacing of 3000 nm. The ion dose in each square was determined by the dwell time for each scanned pixel (with a pitch size of 10.7 nm), varying exponentially (dose =1.182\times 1,176^{j} , being j the index from 1 to 26) from 1.39\text{\,}\mathrm{\SIUnitSymbolMicro C}\text{\,}{\mathrm{cm}}^{-2} (repeated for three squares) to 80\text{\,}\mathrm{\SIUnitSymbolMicro C}\text{\,}{\mathrm{cm}}^{-2} . A 10^{-6}\times(\text{cm}^{-2}/((10^{7})^{2}\,\text{nm}^{2}))\times(1/(1.6\times 10^{-19}\,\text{C})) conversion results in doses ranging from 0.09 ions nm -2 to 5.00 ions nm -2 . For the milled spots, the beam dwelled a fixed pixel for 1 s, 5 s, and 10 s. Additional implantation was carried out to generate alignment marks, L-shaped and triangular, with doses of 80\text{\,}\mathrm{\SIUnitSymbolMicro C}\text{\,}{\mathrm{cm}}^{-2} and 1600\text{\,}\mathrm{\SIUnitSymbolMicro

Read the complete text