Near-perfect efficiency in X-ray phase microtomography

Dominik John 1,2,∗ , Gregor Breitenhuber 1 , Sami Wirtensohn 1,2 , Franziska Hinterdobler 1 , Luka Gaetani 1 , Sara Savatović 1 , Jens Lucht 3 , Markus Osterhoff 3 , Marina Eckermann 4 , Tim Salditt 3 , and Julia Herzen 1 · 2025

Read Near-perfect efficiency in X-ray phase microtomography by Dominik John 1,2,∗ , Gregor Breitenhuber 1 , Sami Wirtensohn 1,2 , Franziska Hinterdobler 1 , Luka Gaetani 1 , Sara Savatović 1 , Jens Lucht 3 , Markus Osterhoff 3 , Marina Eckermann 4 , Tim Salditt 3 , and Julia Herzen 1 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-27282.txt.

Introduction

Dominik John, Gregor Breitenhuber, and nine other co-authors report a gentler way to scan tiny tissue samples in 2025. X-ray tomography builds three-dimensional views from many X-ray shots, but the dose can harm living tissue. Weak detectors force long exposures, and contrast tricks need repeat scans. Their setup attacks both faults at once.

The setup joins three parts: a waveguide that shapes the beam, a patterned modulator, and a photon-counting detector, one that tallies each X-ray hit. It reached near the best possible scores on contrast strength and photon catch in their tests. That means sharp views at one-micrometer scale with far less dose. The team says native, living tissue can now be scanned in ways once out of reach.

Catalog record

CREATORDominik John 1,2,∗ , Gregor Breitenhuber 1 , Sami Wirtensohn 1,2 , Franziska Hinterdobler 1 , Luka Gaetani 1 , Sara Savatović 1 , Jens Lucht 3 , Markus Osterhoff 3 , Marina Eckermann 4 , Tim Salditt 3 , and Julia Herzen 1
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE34 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-27282

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Near-perfect efficiency in X-ray phase microtomography Preprint: APS/123-QED Dominik John 1,2,∗ , Gregor Breitenhuber 1 , Sami Wirtensohn 1,2 , Franziska Hinterdobler 1 , Luka Gaetani 1 , Sara Savatović 1 , Jens Lucht 3 , Markus Osterhoff 3 , Marina Eckermann 4 , Tim Salditt 3 , and Julia Herzen 1 Abstract X-ray microtomography at synchrotron sources is fundamentally limited by the high radiation dose applied to the samples, which restricts investigations to non-native tissue states and thereby compromises the biological relevance of the resulting data. The limitation stems from inefficient indirect detection schemes that require prolonged exposures. Efforts to extract additional contrast through multimodal techniques, like modulation-based imaging, worsen the problem by requiring multiple tomographic scans. In addition, the techniques suffer from low modulator pattern visibility, which reduces measurement efficiency and sensitivity. We address both the detection efficiency and modulation visibility challenges using a novel setup that combines an X-ray waveguide, a structured phase modulator, and a photon-counting detector. Our approach simultaneously achieves near-theoretical limits in both visibility ( 95 % 95\text{\,}\mathrm{\%} ) and quantum efficiency ( 98 % 98\text{\,}\mathrm{\%} ), thereby enabling dose-efficient multimodal microtomography at single-micrometer resolution. This advance will enable new classes of experiments on native-state biological specimens with the potential to advance biomedical research, disease diagnostics, and our understanding of tissue structure in physiological environments. I Introduction X-ray micro-computed tomography (µCT) has enabled valuable three-dimensional insights into biological specimens Thiesse et al. 2010 ; Schambach et al. 2010 ; Eckermann et al. 2020 ; Reichardt et al. 2021 ; Shakeri-Zadeh 2019 ; Metscher 2009a ; Metscher 2009b ; Friedrich and Beutel 2008 and is often considered a non-destructive imaging technique. However, recent investigations have revealed that radiation damage at synchrotron sources poses a significant challenge: Intense X-ray exposure causes severe cellular damage Petruzzellis et al. 2018 , with structural changes detectable from the first moments of exposure Sauer et al. 2022 . These pitfalls limit the reliability of imaging-derived data in biological research Petruzzellis et al. 2018 . High photon flux also produces radicals in wet specimens Fornasiero et al. 2014 , leading to gas bubble formation and sample deformation. To prevent this, samples are typically embedded in paraffin Riedel et al. 2023 or ethanol John et al. 2024 , neither of which preserves the native tissue environment. While computational approaches are being investigated to mitigate dose requirements Obata et al. 2025 , the root of the dose problem lies in the detection technology itself. High-resolution µCT setups at synchrotrons and laboratories employ CCD or CMOS chips coupled to scintillators Longo et al. 2024 , which present a fundamental trade-off between spatial resolution and efficiency: Thicker scintillators increase efficiency but introduce signal blurring. The poor quantum efficiency of these indirect detectors means that much of the radiation passing through the sample is not detected, necessitating higher doses to achieve acceptable image quality. Photon-counting (or direct) detectors circumvent this trade-off, providing dose-efficient imaging through high quantum efficiency Sellerer et al. 2019 ; Gkoumas et al. 2019 , noise-free readout, and sharp pixel response across high dynamic ranges. These advantages have been successfully demonstrated at laboratory sources Sellerer et al. 2019 ; Scholz et al. 2020 . However, the comparatively large pixel size of at least 55\text{\,}\mathrm{\SIUnitSymbolMicro m} Pennicard et al. 2018 has precluded the use of direct detectors for high-resolution synchrotron microtomography, where effective pixel sizes in the single-micrometer range are required. The challenge of dose-efficient imaging is further complicated by the need for enhanced contrast. Many biological tissues exhibit low contrast in conventional attenuation-based imaging, necessitating the development of methods to additionally exploit the phase shift and scattering introduced by the samples. Some of these methods rely on the free-space propagation of the X-ray wavefront as a contrast mechanism and include propagation-based imaging Snigirev et al. 1995 ; Cloetens et al. 1996 ; Paganin et al. 2002 , holography Cloetens et al. 1999 , and ptychography Pfeiffer 2018 . Other techniques employ additional optical elements such as crystal analyzers Bravin 2003 , gratings Weitkamp et al. 2005 ; Bennett et al. 2010 , or various wavefront markers Morgan et al. 2012 ; Bérujon et al. 2012 ; Gustschin et al. 2021 . Speckle-based imaging Morgan et al. 2012 ; Zdora et al. 2017 ; Zdora 2018 , also more generally referred to as modulation-based imaging to include structured diffusers Quenot et al. 2022 ; Savatović et al. 2025 , uses wavefront markers to track changes and displacements in the X-ray wavefront imparted by a sample. This is performed either by explicitly tracking changes in subregions of the image Berujon and Ziegler 2016 ; Zdora et al. 2017 or using a global algorithmic approach Quénot et al. 2021 ; Alloo et al. 2023 . One advantage of the modulation-based approach compared to optics-free methods is that it enables the simultaneous extraction of three imaging modalities related to the sample’s properties: transmission, phase, and small-angle scattering (also known as dark field). In addition, the method enables a quantitative rather than qualitative access to the phase of the examined object in the form of electron density maps Zdora et al. 2020 free of prior assumptions on the sample composition Riedel et al. 2023 . However, these benefits come at the cost of acquiring multiple tomographic scans at different modulator positions, leading to increased measurement time and sample dose. The efficiency of modulation-based imaging critically depends on achieving high visibility, which characterizes the intensity differences in the modulation pattern and directly relates to signal-to-noise ratio Yan et al. 2020 ; Neuwirth et al. 2020 . High visibility enables analysis of weaker signals and permits shortened measurement times, making it essential for measurement and dose efficiency. To address this need, 2D Talbot array illuminators (TAIs) have been recently introduced to increase visibility Gustschin et al. 2021 . Unlike random modulators, such as sandpaper, these optical elements create phase shifts in the wavefront in a regular pattern, with the shift magnitude optimized for maximum visibility at specific energies and measurement distances. While advances in the modulator provide one avenue for increasing visibility, increasing the coherence of the source provides another complementary approach. X-ray waveguides have emerged as a useful tool for creating highly coherent point sources Pfeiffer et al. 2002 . Combined with suitable focusing optics Jarre et al. 2005 ; Salditt et al. 2015 , waveguide-based sources have, for example, been successfully applied to investigate human pathology Eckermann et al. 2020 ; Reichardt et al. 2021 using propagation-based imaging. To simultaneously overcome the mentioned dose efficiency and visibility limitations of conventional micro-computed tomography setups, we propose a novel setup that combines X-ray waveguides with Talbot array illuminators and a photon-counting detector, which has a quantum efficiency of 98\text{\,}\mathrm{\%} at 8\text{\,}\mathrm{keV} dec 2019 . We experimentally characterize the setup’s properties by measuring the achieved visibilities over a range of propagation distances and determine the angular sensitivity using both a direct and an indirect detector. Additionally, we perform and analyze a phase tomography of a biological sample. II Results II.1 Setup Design Figure 1: The radiation produced by an undulator source and filtered by a monochromator (not shown) is focused onto a waveguide via a Kirkpatrick-Baez mirror. A phase modulator is