Design and Implementation of a Fast-Sweeping Langmuir Probe Diagnostic for DC Arc Jet Environments

Sebastian V. Colom, Magnus A. Haw, Jocelino Rodrigues · 2025

Read Design and Implementation of a Fast-Sweeping Langmuir Probe Diagnostic for DC Arc Jet Environments by Sebastian V. Colom, Magnus A. Haw, Jocelino Rodrigues (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-26162.txt.

Introduction

Sebastian V. Colom, Magnus A. Haw, and Jocelino Rodrigues design a fast sweeping Langmuir probe for measuring hot plasma flows. A Langmuir probe is a small electrode whose current, as voltage sweeps, reveals electron temperature, density, and plasma potential. Standard probes sweep too slowly to catch rapid fluctuations in dynamic settings such as an arc jet, a device that heats gas with an electric arc for testing heat shield materials.

Their system sweeps at up to two hundred kilohertz, resolving fast changes, and it is open source, low cost, and adaptable. They validate it in a thirty kilowatt miniature arc jet chamber, where it survived extreme heat conditions and gave time resolved temperature and density profiles across the flow.

Catalog record

CREATORSebastian V. Colom, Magnus A. Haw, Jocelino Rodrigues
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE42 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-26162

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Design and Implementation of a Fast-Sweeping Langmuir Probe Diagnostic for DC Arc Jet Environments Preprint: AIP/123-QED Sebastian V. Colom, Magnus A. Haw, Jocelino Rodrigues Abstract Langmuir probe diagnostics are a cornerstone of plasma characterization, providing critical measurements of electron temperature, electron density, and plasma potential. However, conventional swept Langmuir probes and other traditional electrostatic probes often lack the temporal resolution necessary to capture transient plasma behavior in dynamic environments. This paper presents the design and implementation of a fast-sweeping Langmuir probe system that is open-source, low-cost, and adaptable for a wide range of plasma applications. The probe system incorporates voltage sweeping to resolve rapid fluctuations in plasma parameters at a temporal resolution of up to 200 kHz. To validate its performance, the system was implemented in the 30 kW miniature Arc jet Research Chamber (mARC II), a high-enthalpy DC arc jet facility designed for prototype testing and development. Experimental results demonstrate the probe’s capability to operate in extreme aerothermal conditions, providing time-resolved electron temperature and density along the flow’s radial profile. This work establishes a robust and accessible Langmuir diagnostic solution for researchers studying transient plasma behavior in high-enthalpy environments. I Introduction Langmuir diagnostics, recently crossed their 100-year anniversary since first implemented, are a method for measuring fundamental plasma parameters. These electrostatic probes provide a direct means of characterizing electron density, temperature, and plasma potential Huddlestone and Leonard 1965 ; Chen 2016 . Over the decades, Langmuir probe techniques have evolved from simple single probes to more advanced configurations such as double probes, triple probes Codron and Nawaz 2013 , and emissive probes Martínez et al. 2022 , enhancing measurement accuracy and adaptability in various plasma environments. The fundamental principle involves inserting a conductive electrode into the plasma and applying a voltage to measure the resulting current, which follows a characteristic response owing to electron and ion collection dynamics. By analyzing the current-voltage response, key plasma properties can be determined using theoretical models based on electron energy distributions. Today, Langmuir probes remain a cornerstone of plasma diagnostics, widely used in laboratory Andrenucci, Martín-Saravia, and Ahedo 2019 ; Haw, Seo, and Bellan 2019 ; Efthimion et al. 2005 , fusion Piejak, Godyak, and Alexandrovich 2016 ; Katz et al. 2008 , space Berg et al. 2019 , and industrial Irimiciuc et al. 2021 plasma applications due to their versatility and direct measurement capabilities. An example of a Langmuir probe is a triple probe which uses three electrodes (typically at a fixed bias voltage), offering simplicity and robustness in fluctuating plasmas. However, triple probes are limited in diagnostic range and are forced to assume Maxwellian-distribution properties Polzin et al. 2019 . Emissive probes, used primarily for measuring plasma potential, offer high precision but require additional heating mechanisms. In comparison, Langmuir swept probes operate by continuously varying the applied voltage to measure the full characteristic I – V curve of the plasma. This method allows for the comprehensive determination of plasma parameters, providing a more complete plasma characterization compared to other probe methods. However, swept probes are often challenged by higher-frequency fluctuations present in the plasma environment, introducing errors in the data. In addition, they require more complex electronic circuits for voltage control and data acquisition. The growing interest in temporally resolving electron temperature, electron density, and plasma potential Schubert et al. 2007 ; Troll et al. 2010 stems from the need to understand fast transient phenomena in dynamic plasma environments, such as turbulence Nold et al. 2012 , instability evolution Hu et al. 2021 , pulsed plasma discharges Bose et al. 2018 and confinements Gao et al. 2022 . Typical Langmuir probes provide valuable time-averaged measurements, but lack the temporal resolution necessary to capture rapid fluctuations that significantly influence plasma behavior Lobbia and Gallimore 2010 . Fast-sweeping Langmuir probes address this limitation by enabling real-time tracking of plasma parameters on timescales from milliseconds to nanoseconds Chiodini, Riccardi, and Fontanesi 1999 . These high-temporal resolution diagnostics allow for the identification of fast electron kinetics, instability growth, and wave-particle interactions, offering deeper insights into plasma transport and energy dissipation processes Horton 1990 ; Thomas and Cappelli 1997 . Their application in fusion research, space plasmas, and industrial plasma processing is increasingly vital to optimize performance and advance theoretical plasma models. An example of these applications are direct current (DC) arc jet facilities, high-enthalpy plasma wind tunnels designed to simulate extreme aerodynamic heating conditions encountered during atmospheric entry, spacecraft re-entry, and hypersonic flight. These facilities generate high-enthalpy supersonic flows by sustaining a DC arc discharge between electrodes, heating a working gas to ionized states before accelerating it through a nozzle. The NASA Ames Arc Jet Complex is one of the most advanced facilities of this type, providing crucial testing environments for thermal protection systems (TPS) and ablative materials under realistic entry conditions Terrazas-Salinas 2022 . However, characterizing plasma properties in these environments remains a challenge due to their high enthalpy, non-equilibrium nature, and strong gradients in temperature and density Wang and Sun 2015 ; Meurisse et al. 2018 . For example, there have been several studies in revealing the non-equilibrium nature of DC arc jets and its impact on numerical simulations, highlighting the importance of better understanding the plasma parameter behaviors Guo and Wu 2014 ; Baeva et al. 2016 ; Zube and Myers 1993 . Additionally, previous studies have shown low-frequency (1–10 kHz) oscillatory behaviors in the flow Poulikakos, Zhao, and Arcidiacono 1996 ; Haw et al. 2020 , raising concerns about uncertainty in diagnostic measurements and modeling. Implementing Langmuir diagnostics in arc jet environments presents an opportunity to directly measure electron temperature, electron density, and plasma potential with high spatial and temporal resolution. These measurements are essential for improving computational models, understanding non-equilibrium plasma behavior, and refining heat transfer predictions, ultimately advancing the design and validation of TPS materials for future missions. Thus, the purpose of this paper is to design and develop a fast-sweeping Langmuir probe system that is open-source, low-cost, and adaptable for a wide range of plasma environments. By leveraging modern electronics and data acquisition techniques, the probe system aims to achieve fast voltage sweeping to resolve rapid fluctuations in electron temperature, electron density, and plasma potential. To validate its performance, the system is implemented and tested in the 30 kW DC miniature Arc jet Research Chamber (mARC II), a small-scale arc jet facility developed to support the testing of novel and low technology readiness level concepts Rodrigues et al. 2024a ; Rodrigues et al. 2025a ; Marshall et al. 2025 . This facility provides an ideal testbed for assessing the probe’s capability to operate in high-enthalpy, non-equilibrium plasmas. The results will not only demonstrate the feasibility of using fast-sweeping Langmuir diagnostics in arc jet flows, but also provide an accessible and cost-effective solution for researchers studying transient plasma behavior in various applications. II Hardware Design The hardware design of the fast-sweeping Langmuir probe system is guided by key objectives that align with the broader goals for high-voltage ground testing facilities. These objectives include (1) ensuring a cost-effective solution to enhance accessibility, (2) implementing a battery-powered system to enable portability and electrical isolation from facility power supplies, reducing noise and interference, (3) providing adjustable frequency and voltage sweeping capabilities to

Read the complete text