An OPF-based Control Framework for Hybrid AC-MTDC Power Systems under Uncertainty
Hongjin Du, Rahul Rane, Weijie Xia, Pedro P. Vergara, Aleksandra Lekić · 2025
Read An OPF-based Control Framework for Hybrid AC-MTDC Power Systems under Uncertainty by Hongjin Du, Rahul Rane, Weijie Xia, Pedro P. Vergara, Aleksandra Lekić (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-25671.txt.
Introduction
Hongjin Du led four co-authors on hybrid power control. Rahul Rane, Weijie Xia, and Pedro P Vergara helped. Aleksandra Lekic closes the five-author team. Their 2025 paper controls hybrid AC-MTDC power systems. Renewable integration, especially offshore wind, presents uncertainty. Forecast errors and power fluctuations challenge stability.
Their approach integrates forecasts with optimal power flow. Random Forest models generate wind speed forecasts. A time-coupled optimal flow determines converter setpoints. Setpoints anticipate wind fluctuations before they occur. Real-time adjustment follows actual operating settings then. An changing droop scheme considers two deviations jointly. DC voltage and AC frequency deviations both matter. Hardware-in-the-loop runs validate the approach effectiveness. Stable, robust operation held under high renewable penetration. Hybrid systems mix alternating and direct current grids. Multi-terminal direct current adds control hardness there.
Catalog record
| CREATOR | Hongjin Du, Rahul Rane, Weijie Xia, Pedro P. Vergara, Aleksandra Lekić |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 27 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2510-25671
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
An OPF-based Control Framework for Hybrid AC-MTDC Power Systems under Uncertainty Hongjin Du, Rahul Rane, Weijie Xia, Pedro P. Vergara, Aleksandra Lekić Abstract The increasing integration of renewable energy, particularly offshore wind, introduces significant uncertainty into hybrid AC–HVDC systems due to forecast errors and power fluctuations. Conventional control strategies typically rely on fixed setpoints and neglect frequency deviations, which can compromise system stability under rapid renewable variations. To address this challenge, this paper presents a forecast-integrated, optimal power flow (OPF)-based adaptive control framework. Wind speed forecasts generated using a Random Forest model are incorporated into a time-coupled OPF to determine baseline converter setpoints in anticipation of wind fluctuations, which are further adjusted in real time based on actual operating conditions. An adaptive droop control scheme is developed that jointly considers DC voltage and AC frequency deviations. The effectiveness of the proposed control framework is validated through hardware-in-the-loop (HIL) simulations, demonstrating its capability to ensure stable and robust operation of hybrid AC–HVDC systems under high penetration of renewable energy. \old@ps@headings Index terms – Droop control, VSC-MTDC, Optimal power flow, Wind forecast. \thanksto This work is supported by the CRESYM project Harmony. I Introduction In recent years, the global energy landscape has been undergoing a steady transformation driven by the increasing adoption of renewable energy sources (RESs). Recent analyses, such as Ember’s Global Electricity Review 2025 [ 1 ] , indicate that renewable energy has been playing an increasingly prominent role in global electricity generation over the past decade. Nevertheless, integrating high shares of RESs into large-scale power systems remains a significant technical and operational challenge [ 2 ] . High voltage direct current (HVDC) technology has been widely adopted as an efficient means of long-distance power transmission and renewable energy integration [ 3 ] . Among different technologies, voltage source converter (VSC)-based HVDC, especially with modular multilevel converters (MMCs), has gained prominence due to its advanced controllability. Unlike traditional line-commutated converters (LCCs), VSCs can independently control active and reactive power, operate in weak or even passive grids, and support multi-terminal or meshed configurations. These features make VSCs particularly suitable for hybrid AC-HVDC power systems dominated by renewable energy. With the maturation of VSC–HVDC technology, the key challenge lies not in its technical feasibility but in ensuring secure and coordinated operation under various operating conditions, such as wind forecast uncertainties and grid disturbances. In practice, these challenges are exacerbated by the intermittency and unpredictability of wind generation, which introduces power mismatches and additional operating costs in day-ahead and balancing markets [ 4 ] . The interaction between uncertain wind generation and the dynamics of DC systems further increases operational complexity. Existing studies typically address these mismatches by determining optimal operating points using stochastic or probabilistic optimal power flow (OPF)-based approaches [ 5 , 6 ] . Although such methods better capture uncertainty than deterministic models, they typically impose high computational burdens and exhibit limited scalability, restricting their applicability in large-scale, real-time system operation. Determining optimal operating points through OPF can guide the system toward economically efficient and coordinated operation. However, fixed set points derived from OPF are not suitable for dynamic operating conditions, as they cannot adapt to disturbances or forecast errors and may even lead to oscillations. Hence, maintaining secure operation requires appropriate control strategies. Conventional voltage control strategies include master–slave control, which achieves accurate power sharing but depends on fast and reliable communication, and voltage droop control, which relies solely on local voltage and current measurements. By eliminating the need for extensive communication, droop control enables decentralized operation and improves scalability, making it particularly suitable for multi-terminal HVDC (MTDC) systems [ 7 , 8 ] . However, fixed droop gains may result in uneven power sharing, which can lead to converter overloads or under-utilization [ 9 ] . To improve droop performance, adaptive and nonlinear droop control methods have been proposed in [ 10 , 11 , 12 , 13 ] . Nevertheless, existing control strategies for VSC–MTDC systems are developed under the assumption of constant frequency. As a result, droop strategies are primarily designed for DC voltage regulation, which neglects the inherent coupling between DC variables and AC frequency, as well as the influence of power injections at the point of common coupling (PCC) on overall system dynamics. To address these limitations, this paper proposes a forecast-integrated, OPF-based adaptive control framework for AC–MTDC systems under high renewable penetration. The main contributions of this work are as follows: (1) Random Forest (RF) model-based wind forecasts are incorporated into a time-coupled OPF, capturing the temporal dynamics of renewable generation and enabling more informed operational planning; (2) an adaptive droop control strategy is developed, which dynamically adjusts droop coefficients in real time to enhance voltage and frequency stability and improve power-sharing accuracy across the network; and (3) the effectiveness of the proposed control framework is demonstrated through hardware-in-the-loop (HIL) simulations, highlighting its capability to maintain stable and robust operation of hybrid AC–MTDC systems under high renewable penetration. The remainder of this paper is organized as follows. Section II presents the system modeling and problem formulation. Section III introduces the proposed forecast-integrated OPF and adaptive droop control framework. The feasibility of the proposed control scheme and its transient performance are evaluated through simulations in Section IV, and Section V concludes the paper and outlines directions for future research. II AC–MTDC System Modeling and Optimal Power Flow The hybrid AC–MTDC system considered in this study consists of multiple AC areas interconnected through a VSC-MTDC grid. The overall system model comprises detailed representations of the AC and DC networks, converters, and the OPF formulation used for coordinated operation analysis [ 14 ] . II-A AC System Modelling The AC subgrid is represented by steady-state nodal power flow equations that describe the active and reactive power injections at each bus. For each bus i\in\mathcal{N}_{ac} , the injected powers can be expressed as: \displaystyle P_{i} \displaystyle=U_{i}\sum_{j=1}^{n}U_{j}\left[G_{ij}\cos(\delta_{i}-\delta_{j})+B_{ij}\sin(\delta_{i}-\delta_{j})\right], (1) \displaystyle Q_{i} \displaystyle=U_{i}\sum_{j=1}^{n}U_{j}\left[G_{ij}\sin(\delta_{i}-\delta_{j})-B_{ij}\cos(\delta_{i}-\delta_{j})\right], (2) where U_{i} and U_{j} are the voltage magnitudes at buses i and j , \delta_{i} and \delta_{j} are their corresponding voltage phase angles, and G_{ij} and B_{ij} denote the conductance and susceptance elements of the network admittance matrix, respectively. At each bus, the active and reactive power balances are maintained as: P_{Gi}-P_{Di}-P_{i}=0,\quad Q_{Gi}-Q_{Di}-Q_{i}=0, (3) where P_{Gi} and Q_{Gi} represent the active and reactive power generation, and P_{Di} and Q_{Di} denote the corresponding power demands. Conventional generators are constrained by their operational limits: P_{Gi}^{\min}\leq P_{Gi}\leq P_{Gi}^{\max},\quad Q_{Gi}^{\min}\leq Q_{Gi}\leq Q_{Gi}^{\max}. (4) In addition, the voltage magnitude and phase angle at each bus are constrained by their operational limits: U_{i}^{\min}\leq U_{i}\leq U_{i}^{\max},\quad\delta_{i}^{\min}\leq\delta_{i}\leq\delta_{i}^{\max},\quad\forall i\in\mathcal{N}_{ac}. (5) In hybrid AC–MTDC systems, converter stations are connected at specific AC buses, where their active and reactive power injections appear as additional terms in ( 3 ). These coupling points form the interface between the AC and DC subgrids, enabling coordinated control and optimization across the integrated system. II-B DC System Modelling The DC subgrid is represented by nodal current balance equations that describe the relationship between DC voltages and line currents. For each DC bus m\in\mathcal{N}_{dc} , the injected current can be expressed as: I_{dc,m}=\sum_{n=1,n\neq m}^{N_{dc}}Y_{dc,mn}(U_{dc,m}-U_{dc,n}), (6) where U_{dc,m} and U_{dc,n} denote the DC voltage magnitudes at buses m and n , respectively, and