Optical design and sensitivity optimization of Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS)
Yuki Inoue, Daiki Tanabe, M.Afif Ismail, Vivek Kumar, Mario Juvenal S Onglao III, Ta-Chun Yu · 2025
Read Optical design and sensitivity optimization of Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS) by Yuki Inoue, Daiki Tanabe, M.Afif Ismail, Vivek Kumar, Mario Juvenal S Onglao III, Ta-Chun Yu (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-24780.txt.
Introduction
Yuki Inoue, Daiki Tanabe, M Afif Ismail, Vivek Kumar, Mario Juvenal S Onglao, and Ta-Chun Yu lay out the light design for CHRONOS, a cold scope for low rate gravity waves. The scope forms a three side loop that reads speed, which helps keep quantum noise low at low rates. Twin bars that twist serve as its test weights.
With matrix math and a known light code, they show the loop modes stay stable and match well on entry. The tuned setup hits its goal sense level at one wave per second, set by quantum noise. Low rate noise is shaped most by one side loop's tune. A best read angle near that rate is also given.
Catalog record
| CREATOR | Yuki Inoue, Daiki Tanabe, M.Afif Ismail, Vivek Kumar, Mario Juvenal S Onglao III, Ta-Chun Yu |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 74 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2510-24780
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Optical design and sensitivity optimization of Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS) Yuki Inoue, Daiki Tanabe, M.Afif Ismail, Vivek Kumar, Mario Juvenal S Onglao III, Ta-Chun Yu Abstract We present the optical design and sensitivity modeling of the 2.5 m Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS), a triangular Sagnac speed-meter interferometer incorporating power- and signal-recycling techniques. Using ABCD-matrix analysis and Finesse3 simulations, we show that stable eigenmodes are obtained with optimized mirror curvatures and focal placements, achieving mode-matching efficiencies above 99.5 The resulting configuration reaches a quantum-noise-limited strain sensitivity of h ≃ 3 × 10 − 18 , Hz − 1 / 2 h\simeq 3\times 10^{-18},\mathrm{Hz^{-1/2}} at 1 Hz, with a ring-cavity finesse ℱ ≃ 3.1 × 10 4 \mathcal{F}\simeq 3.1\times 10^{4} and round-trip Gouy phase ψ rt ≈ 153 ∘ \psi_{\mathrm{rt}}\approx 153^{\circ} . The power-recycling cavity detuning ( ϕ p = − 85 ∘ \phi_{p}=-85^{\circ} ) dominates the low-frequency quantum noise, while the signal-recycling cavity detuning ( ϕ s = 0 ∘ \phi_{s}=0^{\circ} ) mainly introduces a uniform quadrature rotation. The optimal homodyne angle ( ζ opt ≃ 46 ∘ \zeta_{\mathrm{opt}}\simeq 46^{\circ} ) balances shot-noise and radiation-pressure effects to give the best sensitivity near 1 Hz. Assuming end-mirror reflectivity R ETM = 99.9999 % R_{\mathrm{ETM}}=99.9999\% under cryogenic operation at 10 K, CHRONOS can achieve quantum-noise-limited performance on a laboratory scale and serve as a testbed for future long-baseline, cryogenic interferometers probing sub-hertz gravitational waves. I Introduction Gravitational-wave astronomy has advanced rapidly through the success of ground-based interferometers such as LIGO, Virgo, and KAGRA Abbott et al. 2016 ; Abbott et al. 2021a ; Akutsu et al. 2019 , and is being further extended into the millihertz band with the upcoming space-based Laser Interferometer Space Antenna (LISA) Amaro-Seoane et al. 2017a . However, a sensitivity gap remains in the sub-hertz band. Ground-based detectors are limited at low frequencies by seismic and environmental noise, while space missions cannot adequately cover this band due to constraints on arm length. Several terrestrial efforts specifically target this regime, such as the torsion-bar antenna (TOBA) Ando et al. 2010 and Torsion Pendulum Dual Oscillator (TorPeDO) McManus et al. 2017 , both of which have demonstrated proof-of-principle operation of sub-hertz detectors. Opening the sub-hertz band would unlock new opportunities for gravitational-wave astronomy. In particular, the merger signals of intermediate-mass black hole (IMBH) binaries exhibit characteristic frequency evolution in this regime. For the Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS) sensitivity scale Inoue et al. 2025 , a facility with an arm length of about 300 m could detect mergers with total mass M\sim 10^{3}M_{\odot} out to 380 Mpc, enabling multi-band observations that bridge LISA and future ground-based detectors. Such observations would provide direct evidence for IMBHs and valuable insights into the formation pathways of supermassive black holes Amaro-Seoane et al. 2017b . Moreover, recent O4 observations have begun to reveal the black-hole mass distribution, with several candidate IMBH events already reported Abbott et al. 2021a ; Abbott et al. 2021b . Measurements in the high-mass regime are particularly important for understanding black-hole formation scenarios, and CHRONOS will offer unique access to this parameter space. In addition, CHRONOS provides unique sensitivity to the stochastic gravitational-wave background ( \Omega_{\rm GW} ) of cosmological origin. With five years of integrated observation, the detector is expected to reach a level of \Omega_{\rm GW}\sim 3\times 10^{-9} at 0.2 Hz. This would directly probe early-universe phenomena such as first-order phase transitions and cosmic strings, thus offering rare opportunities to test physics beyond the standard cosmological model Caprini et al. 2016 ; Ng et al. 2021 . The broader scientific prospects and overall detector concept are discussed in detail in the companion CHRONOS design paper. In this study, we report on the first stage of development: the optical design and sensitivity evaluation of a 2.5 m-scale interferometer. The CHRONOS adopts a triangular Sagnac configuration with output recycling to enhance sensitivity. We investigate suitable sideband signals for controlling multiple cavities, and present design parameters for realistic optical configurations such as dual-recycling cavities. To achieve stable locking of the Sagnac cavity, we compute the mirror-curvature conditions required to reach the desired mode-matching efficiency (99.5%), and confirm consistency across the full optical design. Finally, we calculate sensitivity curves based on the concrete optical layout and discuss the fundamental sensitivity limits of the 2.5 m test facility. II Principle The readout in this study follows the TOBA framework Ando et al. 2010 , which is based on the torsional degree of freedom around the z axis. The angular displacement \theta of a bar-shaped test mass with moment of inertia I , torsional spring constant \kappa , and loss coefficient \gamma obeys I\,\ddot{\theta}(t)+\gamma\,\dot{\theta}(t)+\kappa\,\theta(t)=N_{\mathrm{gw}}(t), (1) where the torque from the gravitational-wave tidal acceleration a_{i}=\tfrac{1}{2}\,\ddot{h}_{ij}\,x^{j} is given by Saulson 1994 ; Forward 1978 N_{\mathrm{gw}}(t)=\frac{1}{2}\,\ddot{h}_{ij}(t)\,\epsilon_{zki}\,Q_{kj}, (2) with Q_{ij}\equiv\int_{V}\rho\!\left(x_{i}x_{j}-\tfrac{1}{3}r^{2}\delta_{ij}\right)dV. (3) In the frequency domain, this becomes \displaystyle\theta(\Omega) \displaystyle=\chi_{\theta}(\Omega)\!\left[-\frac{I_{\mathrm{eff}}}{2}\Omega^{2}\bigl(h_{+}F_{+}+h_{\times}F_{\times}\bigr)\right], \displaystyle\chi_{\theta}(\Omega) \displaystyle\equiv\frac{1}{\kappa-I\Omega^{2}+i\gamma\Omega}, (4) where the torsional resonance \Omega_{t}=\sqrt{\kappa/I} is taken to be well below the observational band (sub-mHz to mHz). In the regime \Omega\gg\Omega_{t} , the susceptibility reduces to \chi_{\theta}\simeq(-I\Omega^{2})^{-1} , yielding \theta(\Omega)\simeq\frac{I_{\mathrm{eff}}}{2I}\bigl(h_{+}F_{+}+h_{\times}F_{\times}\bigr). (5) The total and effective moments of inertia are I=\int\rho(x^{2}+y^{2})\,dV,\qquad I_{\mathrm{eff}}=\int\rho(x^{2}-y^{2})\,dV, (6) such that \eta\equiv I_{\mathrm{eff}}/I\simeq 1 for an ideal thin rod. In the long-wavelength limit with z -axis incidence, the antenna patterns are Forward 1978 F_{+}=\sin 2\alpha,\qquad F_{\times}=-\cos 2\alpha. (7) By combining two orthogonal bars (X and Y) into a differential readout \theta=\theta_{X}-\theta_{Y} , common-mode noise sources such as translational motion and laser intensity fluctuations are suppressed, while retaining sensitivity to linear combinations of the two polarizations Ando et al. 2010 . Figure 1: Schematic of the bar-shaped test masses. Each bar has dimensions of 1100\,\mathrm{mm} in length, 200\,\mathrm{mm} in width, and 220\,\mathrm{mm} in height. Two orthogonal bars (X and Y) are suspended at the center to realize differential torsional readout. III Optical layout An overview of the optical layout is shown in Fig. 2 . The experimental apparatus is based on a cross-torsion-bar configuration, with identical optical systems placed in the X and Y arms. After pre-stabilization, the input laser beam first passes through a pre-stabilized laser (PSL) system and an input mode cleaner (IMC), which stabilize and shape the spatial and frequency profiles Aasi et al. 2015 ; Abbott et al. 2021c . The beam is then split at the input beam splitter (IBS) and directed into the Sagnac interferometers of the X and Y arms. Within each arm, the light propagates through a triangular Sagnac ring cavity, and the returning beams are recombined at the output beam splitter (OBS). The phase difference between the two arms is extracted as the interferometric signal. For convenience, the following description focuses on the Y arm, but it should be noted that the X arm has an identical optical configuration. In the overall CHRONOS program, facility scales of 2.5 m, 40 m, and 400 m have been considered, and their sensitivities compared. In this paper, however, we focus on the 2.5 m-scale interferometer as the first step and discuss in detail the sensitivity evaluation Inoue et al. 2025 . The central part of the interferometer is the triangular Sagnac ring cavity formed by the input