Torque cancellation effect of Intensity noise for Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS)

Daiki Tanabe, Yuki Inoue, Vivek Kumar, Miftahul Ma’arif, Ta-Chun Yu · 2025

Read Torque cancellation effect of Intensity noise for Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS) by Daiki Tanabe, Yuki Inoue, Vivek Kumar, Miftahul Ma’arif, Ta-Chun Yu (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-24779.txt.

Introduction

Daiki Tanabe, Yuki Inoue, Vivek Kumar, Miftahul Ma'arif, and Ta-Chun Yu show how a planned cold gravity wave scope can mute noise from its own laser. The scope, CHRONOS, uses twist bars as test weights and a speed based read that keeps some quantum noise down. It aims to catch waves from mid size black hole pairs far off.

Laser light swings can push the bars by torque, a key noise source at low wave rates. The team shows the bar setup cancels that net push, and that a balanced read helps too. They give the first full math model of this noise for such a scope. That clears one path to the set goal sense level.

Catalog record

CREATORDaiki Tanabe, Yuki Inoue, Vivek Kumar, Miftahul Ma’arif, Ta-Chun Yu
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE42 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-24779

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Torque cancellation effect of Intensity noise for Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS) Daiki Tanabe, Yuki Inoue, Vivek Kumar, Miftahul Ma’arif, Ta-Chun Yu Abstract Detection of sub-Hz gravitational waves is of significant importance in various aspects of astrophysics. It enables us to detect intermediate-mass black-hole mergers, issue early alerts for gravitational-wave events, and explore a landscape of the stochastic background. Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS) is a proposed gravitational-wave detector based on a speed meter that uses torsion bars as end test masses. It aims to achieve 3 × 10 − 18 Hz − 1 / 2 3\times 10^{-18}\,{\rm Hz}^{-1/2} in strain sensitivity at 1 Hz with its prototype design, to detect 𝒪 ⁡ ( 10 4 ) ​ M ⊙ \mathcal{O}(10^{4})M_{\odot} intermediate-mass black-hole mergers at 100 Mpc with a signal-to-noise ratio of 3. We point out that the torsion-bar-based speed meter can suppress noise originating from laser intensity fluctuation by cancellation of torque on the bar and by a balanced homodyne readout. We propose, for the first time, an intensity-noise formula for a gravitational-wave detector employing a Sagnac speed-meter configuration with a torsion bar. Based on our intensity-noise model, we evaluate it for a 2.5-m-arm prototype of CHRONOS. The projected intensity noise was 2.9 × 10 − 20 Hz − 1 / 2 2.9\times 10^{-20}\,{\rm Hz}^{-1/2} which was sufficiently low to detect a binary intermediate-mass black-hole merger. keywords gravitational wave, speed meter, torsion bar, intensity noise † Daiki Tanabe, \linkable [email protected] ‡ Corresponding author: Yuki Inoue, \linkable [email protected] 1 Introduction With the continuing enhancement of gravitational-wave (GW) detector sensitivity, statistical investigations of GW populations—most prominently binary black holes and neutron stars—are becoming increasingly feasible. The initial phase of the fourth joint observing run (O4) of LIGO, Virgo, and KAGRA, which concluded in 2024, reported 128 additional candidate events from compact binary coalescences (CBCs) [ 1 ] . In parallel, major international initiatives, including the planned Laser Interferometer Space Antenna (LISA), are striving to open new observational windows in the millihertz regime, thereby extending the frequency coverage of GW astronomy and providing complementary access to earlier cosmic epochs. The frequency of GWs emitted during the inspiral phase of CBCs scales inversely with the total mass of the system, such that different frequency bands probe distinct astrophysical populations. Frequencies below 1 Hz, in particular, correspond to the characteristic inspiral signals of binaries hosting intermediate-mass black holes (IMBHs) with component masses in the range 10^{3} – 10^{5}\,M_{\odot} [ 2 ] . IMBHs are hypothesized to represent the missing evolutionary stage between the well-established stellar-mass black holes and the supermassive black holes observed in galactic nuclei. Achieving sensitivity in the sub-hertz frequency band is therefore a key to resolving this long-standing mystery of black-hole formation and growth. Although several binary black hole mergers with component masses of \mathcal{O}(10^{2})\,M_{\odot} have been detected, robust observational evidence for binaries above 10^{3}\,M_{\odot} remains elusive [ 3 , 4 ] . A Sagnac speed meter based on a cryogenic torsion bar, named the Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS), has been proposed as a novel gravitational-wave (GW) detector optimized for the sub-hertz band [ 5 ] . The concept of using torsion bars as end test masses in GW detectors has been pioneered by the Torsion-Bar Antenna (TOBA) and the Torsion Pendulum Dual Oscillator (TorPeDO) [ 6 , 7 ] . A key advantage of the torsion-bar design lies in the yaw rotation mode of a fiber-suspended bar, whose resonant frequency is significantly lower than that of the translational pendulum mode of a suspended mirror, thereby providing strong suppression of seismic noise. In parallel, the speed-meter principle reduces the quantum noise scaling in frequency space from 1/f^{2} to 1/f [ 8 ] . Combining these two features—the torsion bar and the speed-meter topology—enables a compact detector design while maintaining sufficient low-frequency sensitivity. The CHRONOS program envisions three configurations with different arm lengths, adapted to existing GW test facilities: 2.5 m, 40 m, and 300 m. In its ultimate 300-m configuration, CHRONOS aims to reach a strain sensitivity of 1\times 10^{-18}\,{\rm Hz}^{-1/2} at 1 Hz, sufficient to detect gravitational waves from \mathcal{O}(10^{4})\,M_{\odot} binary IMBH mergers out to a luminosity distance of \sim 380 Mpc with a signal-to-noise ratio (SNR) of 3. The intermediate 40-m configuration targets 2\times 10^{-18}\,{\rm Hz}^{-1/2} , while the 2.5-m prototype aims for 3\times 10^{-18}\,{\rm Hz}^{-1/2} . Even in this prototype setup, CHRONOS would retain the capability to detect \mathcal{O}(10^{4})\,M_{\odot} binary IMBH mergers within \sim 100 Mpc with an SNR of 3. In this study, we present the first attempt to construct an intensity-noise model for a torsion-bar detector combined with a speed-meter topology. We demonstrate that a common-mode cancellation mechanism against laser intensity noise operates in this configuration by combining numerical analysis with the finite-element analysis (FEA) software COMSOL and an analytical model [ 9 ] . Specifically, (i) we take into account the torque cancellation effect arising from the geometrical symmetry of mirrors mounted on the torsion bar, and (ii) we calculate the noise using the transfer function of CHRONOS operating as a speed meter obtained with FINESSE3 [ 10 ] . In this way, we incorporate a concrete optical system into the simulation and evaluate the intensity-noise suppression effect inherent to the torsion-bar speed-meter configuration. In the following part of this paper, we provide a formula of intensity noise of a torsion-bar-based speed meter and evaluate it based on 2.5-m configuration of CHRONOS. Sec. 2 describes a mathematical model of intensity noise in terms of spacetime strain. Sec. 3 presents simulations of the surface displacement of the torsion bar with a realistic beam-position misalignment as a part of the intensity noise model. Sec. 4 evaluates the intensity noise of CHRONOS using the designed parameters and the laser-intensity fluctuation measured in a previous study. Sec. 5 discusses case studies of 40-m and 300-m options, followed by an interpretation of the simulation results. 2 Intensity-noise model 2.1 General detection principle of speed meter with torsion bar A simplified schematic view of CHRONOS optics is shown in Fig. 1 . Here we focus only on a single bar because of the symmetries of the two bars and their associated optical layouts. An input laser beam is split into clockwise and counterclockwise paths by the first beam splitter. The beam on each path hits the left or right mirror attached to the bar. The mirrors are attached at horizontally symmetric positions on the bar and form triangular cavities at each side of the bar. The phase difference between the two paths accumulated during resonance in the triangular cavities is proportional to the rotation velocity of the bar, while GW strain generates a rotation angle. As the rotation velocity and angle are related by \dot{\theta}(\omega)=i\omega\theta(\omega) , this configuration can reduce the slope of the quantum noise spectrum from 1/f^{2} to 1/f , which makes it particularly advantageous at low frequencies [ 8 ] . Figure 1: Simplified optical path of CHRONOS. One torsion bar and balanced-homodyne detection part are shown. Relationship between the rotation angle and GW strain follows a known second-order differential equation relating angle and torque. A

Read the complete text