A Sub-kHz Mechanical Resonator Passively Cooled to 6 mK

Loek van Everdingen, Jaimy Plugge, Tim M. Fuchs, Guido L. van de Stolpe, Dalal Benali, Thijmen de Jong, Jasper Bijl, Wim A. Bosch, Tjerk H. Oosterkamp · 2025

Read A Sub-kHz Mechanical Resonator Passively Cooled to 6 mK by Loek van Everdingen, Jaimy Plugge, Tim M. Fuchs, Guido L. van de Stolpe, Dalal Benali, Thijmen de Jong, Jasper Bijl, Wim A. Bosch, Tjerk H. Oosterkamp (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-24199.txt.

Introduction

Loek van Everdingen and eight co-authors cooled a tiny beam that bends and vibrates to about six thousandths of a degree above absolute zero. Beams like this can sense very small forces. If they stay in balance with their cold surroundings, they may keep a clean motion for longer. The beam hums near seven hundred times per second and weighs about one and a half billionths of a gram.

The team cooled it with no active fridge on the device. They used a method based on nuclear spin loss of heat. They then tracked the beam's tiny heat driven motion with a lock in tool. Even at the coldest point, that motion stood out from the noise. It also matched the spread that heat theory predicts. The work opens a path to cool such beams below one thousandth of a degree.

Catalog record

CREATORLoek van Everdingen, Jaimy Plugge, Tim M. Fuchs, Guido L. van de Stolpe, Dalal Benali, Thijmen de Jong, Jasper Bijl, Wim A. Bosch, Tjerk H. Oosterkamp
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE51 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-24199

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A Sub-kHz Mechanical Resonator Passively Cooled to 6 mK Preprint: APS/123-QED Loek van Everdingen, Jaimy Plugge, Tim M. Fuchs, Guido L. van de Stolpe, Dalal Benali, Thijmen de Jong, Jasper Bijl, Wim A. Bosch, Tjerk H. Oosterkamp Abstract Fundamental tests of quantum mechanics, such as the generation of non-classical states and tests of wavefunction collapse models, are performed on increasingly larger size and mass scales. Highly coherent mechanical resonators, which also prove invaluable in ultrasensitive microscopy methods, are essential tools towards these efforts. Studying these resonators in a thermal equilibrium state at millikelvin temperatures provides a promising path to increase their coherence time. Here, we passively cool a 700 Hz 700\text{\,}\mathrm{H}\mathrm{z} massive ( 1.5 ng 1.5\text{\,}\mathrm{n}\mathrm{g} ) mechanical cantilever down to 6.1 ​ ( 4 ) ​ mK 6.1(4)$\mathrm{m}\mathrm{K}$ by means of nuclear demagnetization, as confirmed by detecting its thermal motion via a lock-in based detection scheme. At the lowest temperatures the thermal motion of the resonator is still clearly distinguishable from the background noise. Our data analysis confirms that at these temperatures the motion is still thermally distributed. These results pave the way for passive cooling low-frequency resonators to the sub-milllikelvin regime, which would enable new tests of quantum mechanics and advances in ultrasensitive force detection. The quantum-to-classical boundary addresses fundamental questions concerning wavefunction collapse Vinante et al. 2019 ; Nimmrichter and Hornberger 2013 and the interaction between quantum mechanics and gravity Oppenheim et al. 2023 ; Bose et al. 2025 ; Schrinski et al. 2023 . Despite of significant efforts, in terms of mass, there is currently still a large discrepancy between the largest object that was brought in a spatial superposition Fein et al. 2019 ; Bild et al. 2023 and the smallest objects that served as a source of gravity Westphal et al. 2021 ; Fuchs et al. 2024 . Essential tools towards closing this quantum-to-classical gap are mechanical resonators with favorable properties, such as high Q-factors Eichler 2022 ; Seis et al. 2022 , low force noise Janse et al. 2024 ; Héritier et al. 2018 ; Gisler et al. 2022 and good displacement sensitivity Lee et al. 2023 ; De Bonis et al. 2018 . These properties tend to improve at lower resonator temperature and consequently experiments are generally carried out at cryogenic temperatures Stowe et al. 1997 . To reach such low temperatures, both active and passive forms of cooling are being explored. Active cooling requires continuous driving of a mode, such as feedback cooling Zoepfl et al. 2023 or sideband cooling Youssefi et al. 2023 , and has been employed to cool mechanical resonators in a wide range of frequencies into their ground state Teufel et al. 2011 ; Delić et al. 2020 ; Guo et al. 2019 ; Seis et al. 2022 . However, active cooling does not improve the force noise of the ground state because it does not lower the temperature of the environment. Moreover, it is undesirable in experiments probing quantum systems, as it disturbs a system from mechanical equilibrium via the external drive. On the contrary, passive cooling leaves a mechanical system in thermal equilibrium, once cold. It was first used to cool GHz systems to their ground state at the operation temperature of a dilution refrigerator O’Connell et al. 2010 . A widely-applied form of passive cooling is nuclear demagnetization, which has been used to cool microelectronics below 1\text{\,}\mathrm{m}\mathrm{K} Sarsby et al. 2020 ; Batey et al. 2013 , and was recently employed to cool a 15 MHz device into its motional ground state Cattiaux et al. 2021 . However, bringing sub-kHz mechanical probes to sub-mK temperatures while leaving them in thermal equilibrium remains a formidable challenge Pickett and Enss 2018 . If achieved, it has the potential to improve the Q-factor of highly-coherent mechanical resonators by mitigating mechanical loss channels Maillet et al. 2023 ; van Heck et al. 2023 . Mechanical sensors with a high Q-factor and low-force noise find application in the aforementioned experiments on the quantum-to-classical boundary and in ultrasensitive detection, including extreme mass sensing Westphal et al. 2021 ; Fuchs et al. 2024 and acceleration detection Monteiro et al. 2020 . Additionally, they prove an essential tool to test models of wave function collapse, such as Diosí-Penrose models and Continuous Spontaneous Localization (CSL) Carlesso et al. 2022 ; Bassi et al. 2013 ; Vinante et al. 2016 . In this work, we apply nuclear demagnetization to cool a 1.5\text{\,}\mathrm{n}\mathrm{g} mechanical resonator to 6.1(4)\text{\,}\mathrm{mK} . By introducing a lock-in detection scheme that tracks the resonator energy, we are able to verify the thermal equilibrium nature of its state through the direct observation of Boltzmann energy statistics. To our knowledge, this is the first observation of the equilibrium motion of a massive mechanical resonator in the Hz- to kHz-regime below the 20\text{\,}\mathrm{mK} base temperature of conventional dilution refrigerators. .1 Experimental setup Figure 1: Schematic illustration of the setup used for this work. A thermally isolated silver wire is linked to the nuclear demagnetization stage and connects different parts of the experiment, notably the cantilever, detection chip and input transformer to a temperature below the base temperature of the dilution refrigerator at 20mK. The lower right corner of the schematic shows the circuit that is used for the detection and calibration of the cantilever motion. The position inside the dilution refrigerator of different parts is indicated. In the center part the MFFT is illustrated inside its lead shielding (purple). The lower part shows the cantilever suspended above the detection circuit. The experimental setup used in this work was originally designed for magnetic resonance force microscopy (MRFM) at low temperatures (see Fig. 1 ). A soft silicon cantilever Chui et al. 1995 with a magnetic tip ( \text{Nd}{\vphantom{\text{X}}}_{\smash[t]{\text{2}}}\text{Fe}{\vphantom{\text{X}}}_{\smash[t]{\text{14}}}\text{B} sphere, 7.3 \mu\textrm{m} diameter) is suspended above a pickup loop in a pulse tube cryogen-free dilution refrigerator (Leiden Cryogenics CF-1200). To minimize mechanical vibrations, the experiment is mounted on a mass-spring suspension system hanging inside the dilution refrigerator. The cantilever exhibits a resonance frequency \omega_{0}\approx 2\pi\times$700\text{\,}\mathrm{H}\mathrm{z}$ and a spring constant of 26\text{\,}\mu\mathrm{N}\mathrm{m}^{-1} . Magnetic flux induced in the pickup loop generates a current in a SQUID input coil of a two-stage readout SQUID (Magnicon NC-1 Integrated Two-Stage Current Sensor), and hence a voltage signal. Precise positioning of the cantilever is achieved using a piezomotor system comprising three independently controllable spindles actuated by slip-stick piezomotors. Oscillations of the cantilever can be driven electrically through a dither piezo that excites the cantilever base. The amplitude of the cantilever oscillations can be calibrated through a calibration coil which excites the cantilever magnetically, and which is located between the pickup loop and the readout SQUID input coil. The cantilever frequency varies at different positions due to local forces acting on the cantilever. The local forces cause a change in the effective stiffness k_{\textrm{eff}} , which causes variations in the effective resonance frequency \omega_{eff} . To achieve cooling of the cantilever below the base temperature of the dilution refrigerator ( \sim$20\text{\,}\mathrm{mK}$ ), we thermally anchor both the cantilever and the detection chip to a \text{PrNi}{\vphantom{\text{X}}}_{\smash[t]{\text{5}}} nuclear demagnetization stage using a silver wire (contrary to previous work where only the cantilever was connected van Heck et al. 2023 ). Crucially,the silver strip is

Read the complete text