Design and characterization of a photosensor system for the RELICS experiment
and Chenhui Zhu · 2025
Read Design and characterization of a photosensor system for the RELICS experiment by and Chenhui Zhu (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-24196.txt.
Introduction
Jijun Yang and forty seven co-authors describe a photosensor system built for the RELICS experiment and how it was tested. The surface level detector faces intense cosmic muon backgrounds that can saturate its photomultiplier tubes, blinding them to faint signals. To handle this, the team designed a base with an extended dynamic range.
The system reads out each tube at two points, the anode and the seventh dynode, to widen the range of linear response. Tests of Hamamatsu R8520-406 tubes confirm stable running under positive high voltage and a linear range extended by more than tenfold. A model of saturation and recovery also gauges how muon signals will affect the detector.
Catalog record
| CREATOR | and Chenhui Zhu |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 33 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2510-24196
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Design and characterization of a photosensor system for the RELICS experiment and Chenhui Zhu Abstract In this paper, we present the design and characterization of a photosensor system developed for the RELICS experiment. A set of dynamic readout bases was designed to mitigate photomultiplier tube (PMT) saturation caused by intense cosmic muon backgrounds in the surface-level RELICS detector. The system employs dual readout from the anode and the seventh dynode to extend the PMT’s linear response range. In particular, our characterization and measurements of Hamamatsu R8520-406 PMTs confirm stable operation under positive high-voltage bias, extending the linear response range by more than an order of magnitude. Furthermore, a model of PMT saturation and recovery was developed to evaluate the influence of cosmic muon signals in the RELICS detector. The results demonstrate the system’s capability to detect coherent elastic neutrino–nucleus scattering ( CE ν \nu NS ) signals under surface-level cosmic backgrounds, and suggest the potential to extend the scientific reach of RELICS to MeV-scale interactions. 1 Introduction The detection of coherent elastic neutrino-nucleus scattering ( CE \nu NS ) is not only crucial for constraining the standard model (SM) of particle physics [ 1 , 2 ] , but also provides new experimental techniques and theoretical frameworks that advance interdisciplinary research across astrophysics, nuclear physics, and dark matter detection. For example, CE \nu NS is crucial for measuring the weak mixing angle in SM at low energy [ 3 ] , investigating non-standard neutrino interactions [ 4 ] , searching for sterile neutrinos [ 5 ] , and exploring neutrino electromagnetic properties [ 6 ] . Furthermore, CE \nu NS offers a unique window into the study of nuclear structure [ 7 ] , and plays a critical role in understanding the mechanisms driving core-collapse supernova explosions [ 8 ] . The CE \nu NS signals originating from solar and atmospheric neutrinos constitute an irreducible background in dark matter detection experiments [ 9 , 10 ] . Thus, the precise measurement of CE \nu NS is essential for dark matter searches beyond the so-called ”neutrino floor” [ 11 , 12 ] , enhancing the experimental sensitivity of those experiments. The dual-phase liquid xenon (LXe) time projection chamber (TPC) has been the leading technology in the direct detection of dark matter for decades [ 13 , 14 , 15 , 16 , 17 ] . The low energy threshold of ionisation signals makes LXe TPC particularly advantageous for detecting weak signals such as CE \nu NS . Using a cylindrical TPC of 24\text{\,}\mathrm{cm} in height and 28\text{\,}\mathrm{cm} in diameter, with arrays of 64 Hamamatsu R8520-406 1-inch photomultiplier tubes (PMTs) both top and bottom, the REactor neutrino LIquid xenon Coherent Scattering (RELICS) experiment aims to take advantage of this robust, low-threshold technology to detect CE \nu NS process of reactor neutrinos at the Sanmen nuclear reactor site [ 18 ] . Unlike deep-buried dark matter experiments, conducting low-energy event searches at the surface level presents significant challenges due to cosmic ray related backgrounds [ 19 , 20 , 21 , 22 , 23 ] . Among them, cosmic muons are one of the main sources of backgrounds of the RELICS experiment, with the rate of 1\text{\,}\mathrm{\text{event}}\text{\,}{\mathrm{cm}}^{-2}\text{\,}{\mathrm{min}}^{-1} [ 24 ] . The energy deposition of muons will cause strong prompt scintillation (S1) and produce a large number of ionisation electrons responsible for the secondary proportional ionisation scintillation (S2), as shown in figure 1 . Both S1 and S2 from muons will cause the PMT anodes to saturate, but to different extents. This saturation effect is known to have time and energy dependences as the PMTs recharge and recover. Moreover, the muon-induced backgrounds, such as neutrons and delayed electrons, are the key background components for the search of CE \nu NS [ 25 ] , which requires a precise reconstruction of the muon directional information [ 18 ] . Both effects are crucial for the scientific goals of the RELICS experiment, which require the photo-sensor system to have a wider dynamic range to the larger energy side. Figure 1 : The schematic diagram of a cosmic-ray muon traversing through the RELICS LXe TPC, producing the initial S1 and S2 signals (waveforms not to scale). Delayed emission of single- and few-electron follows the initial ionization signal by muons, which shows both position and time correlations. In this paper, we begin by analysing the muon-related background in the RELICS experiment, outlining the motivations and requirements. We then describe the design of the dynamic readout base, especially the design of dynode readout in section 3 . The performance and tests of dynode (anode) readout are discussed in section 4 ( 5 ). Based on these results, we investigate the saturation responses of PMTs and model the time- and energy-dependent saturation behaviours, which lays a foundation for a full signal recovery technology. Finally, we close the topic by discussing the current design and possible outlooks in section 7 . 2 Muon-induced backgrounds The RELICS detector is located at the surface, where no natural shielding exists. As a result, it is directly exposed to cosmic muons with a mean energy of approximately 4\text{\,}\mathrm{GeV} and event rate \mathcal{O}($10\text{\,}$)~$\text{\,}\mathrm{Hz}$ , according to the size of the RELICS TPC [ 26 , 24 ] . This results in significant background events and elevated data bandwidth consumption. The RELICS experiment mainly focuses on the detection of the low-energy CE \nu NS signal from 0.63\text{\,}\mathrm{keV} to 1.36\text{\,}\mathrm{keV} , roughly equivalent to 120\text{\,}\mathrm{PE} to 300\text{\,}\mathrm{PE} . This naturally requires the detector to be extremely sensitive to low-energy events [ 18 ] . However, muons in LXe with 4\text{\,}\mathrm{GeV} energy has a stopping power of about 5\text{\,}\mathrm{MeV}\text{\,}{\mathrm{cm}}^{-1} [ 27 ] . In RELICS TPC, a vertical muon could deposit 120\text{\,}\mathrm{MeV} inside the fiducial volume, producing 10^{6} photoelectrons (PE) within 100\text{\,}\mathrm{ns} . The mean S1 intensity received by each PMT is therefore about 480\text{\,}\mathrm{PE}\text{\,}{\mathrm{ns}}^{-1} [ 28 ] . Such a large S1 can easily cause the saturation of PMTs. At the same time, the mean intensity of S2 can reach up to 10\text{\,}\mathrm{PE}\text{\,}{\mathrm{ns}}^{-1} with a long duration of up to 178\text{\,}\mathrm{\SIUnitSymbolMicro s} . Moreover, delayed ionization signals comprising only single or a few electrons are observed in liquid xenon TPCs after large S2 and can persist for up to \mathcal{O}(1) second [ 25 , 29 , 30 ] . These delayed electrons can lead to substantial accidental coincidence backgrounds, adversely affecting CE \nu NS detection. Researches from XENON1T [ 25 ] and LUX [ 30 ] indicate that delayed electrons exhibit correlations with physical processes in both time and space. In RELICS, the delayed electron pile-up background in the low-energy region could exceed the CE \nu NS signal by four orders of magnitude [ 18 ] , which can be suppressed by considering the time and spatial correlations of delayed electrons with the muon’s trajectory. Thus, dynamic readout technologies need to be developed and optimized to address PMT saturation and enable the accurate collection of both energy and timing information from muon events. In addition, understanding of the muon trajectory would allow even precise tagging of the muon-induced neutron background, albeit in ref. [ 18 ] , such a background is deemed subdominant. A solution to this