The Geometry of Contraction-Induced Flows

Aaron Winn, Eleni Katifori · 2025

Read The Geometry of Contraction-Induced Flows by Aaron Winn, Eleni Katifori (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-24016.txt.

Introduction

Aaron Winn and a co-author work out the fluid mechanics of peristalsis when a tube contracts in both directions at once. Peristaltic pumping — a wave of wall contraction squeezing fluid along — drives flows from intestines to engineered devices. Most models impose the radius changes and ignore the length changes that radial squeezing naturally causes in elastic walls, yet net flow depends on those details.

The authors track the fluid in the Lagrangian coordinates of the elastic tube, treating it as flow inside a fixed boundary with a time-dependent metric. The analysis holds even for large contractions, which they confirm against COMSOL simulations. Transverse and longitudinal contractions push flows of the same order but in opposite directions. The wall's Poisson ratio matters: incompressible walls suppress flow by minimizing volume change, while auxetic walls enhance it. Length-driven waves typically produce backflow, though trapping survives at large amplitudes.

Catalog record

CREATORAaron Winn, Eleni Katifori
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE122 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-24016

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

The Geometry of Contraction-Induced Flows Aaron Winn, Eleni Katifori Abstract Peristalsis is the driving mechanism behind a broad array of biological and engineered flows. In peristaltic pumping, a wave-like contraction of the tube wall produces local changes in volume which induce flow. Net flow arises due to geometric nonlinearities in the momentum equation, which must be properly captured to compute the flow accurately. While most previous models focus on radius-imposed peristalsis, they often neglect longitudinal length changes — a natural consequence of radial contraction in elastic materials. In this paper, to capture a more accurate picture of peristaltic pumping, we calculate the flow in an elastic vessel undergoing contractions in the transverse and longitudinal directions simultaneously, keeping the geometric nonlinearities arising in the strain. A careful analysis requires us to study our fluid using the Lagrangian coordinates of the elastic tube. We perform analytic calculations of the flow characteristics by studying the fluid inside a fixed boundary with time-dependent metric. This mathematical manipulation works even for large-amplitude contractions, as we confirm by comparing our analytical results to COMSOL simulations. We demonstrate that transverse and longitudinal contractions induce instantaneous flows at the same order in wall strain, but in opposite directions. We investigate the influence of the wall’s Poisson ratio on the flow profile. Incompressible walls suppress flow by minimizing local volume changes, whereas auxetic walls enhance flow. For radius-imposed peristaltic waves, wall incompressibility reduces both reflux and particle trapping. In contrast, length-imposed waves typically generate backflow, although trapping can still occur at large amplitudes for some Poisson ratios. These results yield a more complete description of peristalsis in elastic media and offer a framework for studying contraction-induced flows more broadly. I Introduction Peristalsis, defined as fluid flow driven by the cyclic contraction of a tube wall, is ubiquitous in biological systems. Peristaltic waves drive fluid transport in the digestive system Nicosia2001LocalUltrasonography ; Pal2002TheTransport ; BrasseurEtAl2007 , ureter Carew_Pedley_1997 ; Kalayeh_Xie_Brian_Fowlkes_Sack_Schultz_2023 , lymphatic system Moore2018LymphaticFlows ; Wolf2021FluidValves ; Winn2024OperatingValves , and perivascular spaces of the brain Carr2021PeristalticTubes ; Trevino2025LowSpace . Much theoretical work has been done to characterize peristaltic flows, typically in the context of radius-imposed peristalsis. In the models of radius-imposed peristalsis, the transverse motion of the tube wall is imposed and propagates as a wave, while the longitudinal wall motion is fixed to zero. Burns and Parkes presented an early theoretical treatment of radius-imposed peristalsis and were able to solve for the stream function for arbitrary wavelength deformations Burns_Parkes_1967 , but only at small amplitude. Transverse oscillations in a 2D planar geometry were the focus of the paper, though corrections for a tube with longitudinal displacements derived by enforcing tube inextensibility were briefly calculated. Incorporating inextensibility acknowledges that the deforming boundary is not an arbitrary mathematical function, but that it should actually obey physical material constraints. This approach was also taken to study the related problem of a swimming flagellated micro-organism Taylor_1951 . However, the majority of papers released since these pioneering works have ignored the mechanical properties of the wall, and Burnes and Parkes even noted that the difference between the problem with purely transverse oscillations and that where inextensibility is applied can be ignored Burns_Parkes_1967 . In this work we will see that, particularly in cases of large-amplitude peristalsis beyond where the perturbative approach of Burnes and Parkes is valid, longitudinal wall motion can have substantial consequences on peristaltic flow. Soon after the work of Burnes and Parkes, Shapiro, et al. further analyzed radius-imposed peristalsis, relaxing the assumption of small-amplitude deformation, but only at long wavelengths in an infinitely long tube under the lubrication approximation Shapiro_Jaffrin_Weinberg_1969 . This led to an exact expression for the average flow given an arbitrary pressure drop per wavelength. The trick to solving for peristaltic flow is to recognize that if the boundary propagates as a wave, then the flow is steady in the co-moving frame. This property not only allows for analytic calculation of the flow, but also simplifies the calculation of particle trajectories. Shapiro, et al. highlight two interesting phenomena: reflux, where particles close to the wall travel against the wave direction, and trapping, where at large amplitude a bolus forms in which particles are trapped and move on average at the wave speed. A summary of early work on radius-imposed peristalsis including finite Reynolds number effects is given in Jaffrin_Shapiro_1971 . It is not too difficult to generalize the calculations to a finite tube, though the flow in that case is inherently non-steady Li1993Non-SteadyTubes . Later numerical studies relaxed some or all assumptions regarding amplitude, wavelength, and Reynolds number, for the case of a 2D geometry Pozrikidis_1987 Takabatake_Ayukawa_1982 and a cylindrical geometry Takabatake_Ayukawa_Mori_1988 . All of these studies highlight the importance of keeping the nonlinear radius scaling in the conductance since the trapping phenomenon can only be observed at large amplitude where the geometric nonlinearities are important. However, all of these studies also neglect the mechanics of the tube wall and longitudinal wall motion. Contrasted with radius-imposed peristalsis, in force-imposed peristalsis, a wave-like force is imposed on the exterior of a tube wall, and the boundary displacements are solved for alongside the fluid variables Tang1993NumericalBoundaries . This is one way in which elastic tube properties can be incorporated into models of peristaltic pumping. Takagi and Balmforth show that radius-imposed peristalsis can be considered a special case of force-imposed peristalsis, where radial forces on the exterior of the tube balance with fluid force to displace the tube wall Takagi_Balmforth_2011 . Their paper highlights the important role that vessel stiffness plays in governing peristaltic flows. The tube radius will only deform in phase with the applied force when the vessel is sufficiently stiff. However, their work neglects longitudinal wall motion and shear forces. An even more complex class of peristalsis models separately treat passive elastic forces and active muscle contraction Carew_Pedley_1997 ; KouEtAl2015_ActiveMusculoMechanical , though these models are limited to computational studies. To incorporate the effects of longitudinal wall motion, one needs to consider the coupling of the components of the strain tensor by the mechanics of the elastic wall. For a cylindrical tube modeled as a 2D axisymmetric membrane, there are two in-plane components of the strain tensor. Relaxing the symmetry constraint or allowing for finite tube thickness only further complicates the matter by introducing even more strains. These various coupled strains together determine the contraction-induced flow. In particular, we will see that longitudinal wall motion contributes to fluid flow at the same order in strain as transverse wall motion, despite being ignored in most cases. This longitudinal wall motion is well documented in the esophagus Nicosia2001LocalUltrasonography ; Pal2002TheTransport ; BrasseurEtAl2007 ; KouEtAl2015 ; KouEtAl2015_ActiveMusculoMechanical and has also been described in the ureter Carew_Pedley_1997 ; Kalayeh_Xie_Brian_Fowlkes_Sack_Schultz_2023 and aorta AghilinejadEtAl2023 . Perhaps the clearest demonstration of coupled transverse and longitudinal peristaltic waves in biology can be seen in the locomotion of earthworms where longitudinally stretched regions correspond to regions of smaller diameter and longitudinally squished regions correspond to regions of larger diameter Quillin1999KINEMATICTERRESTRIS . This same coupling occurs in the esophagus, which is believed to be incompressible: the muscle cross-sectional area and length are inversely proportional so that the the volume remains constant Nicosia2001LocalUltrasonography . This simple coupling between strain components

Read the complete text