Read Validation of field cage and cathode for low radioactivity operation with the CYGNO experiment by D. Tozzi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-23229.txt.

Introduction

F D Amaro leads a collaboration of fifty one researchers characterizing parts of the CYGNO dark matter detector for low-radioactivity running. Dark matter makes up about twenty seven percent of the universe mass-energy, yet its makeup is unknown. CYGNO hunts low-energy nuclear recoils from dark matter in a gas time projection chamber with optical readout.

This report focuses on the field cage and cathode of the demonstrator now under construction. Both parts must add almost no background radioactivity, or faint signals drown. Careful material and design checks are essential before the full directional search for dark matter can begin.

Catalog record

CREATORD. Tozzi
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE28 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-23229

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Validation of field cage and cathode for low radioactivity operation with the CYGNO experiment D. Tozzi Abstract Dark matter, which is considered to account for approximately the 27% of the Universe’s energy-mass content, remains an open issue in modern particle physics along with its composition. The CYGNO Experiment aims to exploit an innovative approach applied to the direct detection search of low energy nuclear recoils possibly induced by cold particle-like dark matter candidates. CYGNO employs a directional detector based on a Time Projection Chamber (TPC) filled with a He:CF 4 gas mixture and equipped with an optical readout. Currently, the CYGNO Collaboration is constructing the detector demonstrator, CYGNO-04, in Hall F at Laboratori Nazionali del Gran Sasso (LNGS). This 0.4 m 3 detector has the goal of proving the scalability of the technology and assessing the physics and radiopurity capabilities. Given the low radioactivity requirements, especially in internal components such as field cage and cathode, the reduction of material while keeping the correct electrical behavior is paramount. In this paper, we present the validation of several internal components, mainly focusing on the field cage material and support structure. The tests included geometrical asymmetries in the electric field response, collection efficiency as well as measurement of known physical quantities. A preferred configuration is found with a structure based on Nylon material which supports a PET or Kapton sheet with copper strips deposited on. 1 Introduction Dark matter (DM) remains one of the most significant unresolved questions in modern physics. Its possible presence is suggested by a plethora of astrophysical, astronomical and cosmological observations which probed our Universe at different scales. In the current leading theories, DM is considered to constitute approximately 27% of the Universe’s total mass-energy content and it interacts with ordinary matter only through gravity and possibly another unknown weak interaction [ 1 ] . Despite extensive research, the composition of DM remains unknown. One of the leading hypotheses is that it consists of Weakly Interacting Massive Particles (WIMPs) or WIMP-like particles. These hypothetical particles can naturally arise in several extensions of the Standard Model of particle physics and can be thermally produced in the early Universe to match the abundance estimated today. They are characterized by extremely weak interaction with Standard matter, by being neutral, non-baryonic and cold, i.e. non-relativistic at the decoupling phase with regular matter. As DM particles are expected to populate a halo around our Galaxy, a possible method to detect them is to directly observe the rare standard matter recoils induced by them. Direct detection experiments are exploring this possibility, mostly focusing on nuclear recoils (NRs) for kinematic reasons, in a theoretical justified range of DM masses from hundreds of MeV/c 2 up to TeV/c 2 scale [ 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 ] . Moreover, the motion of the Solar system through the Galaxy with a speed similar to the average one of DM particles induces a peculiar dipolar structure to the angular distribution of the NRs. This feature is considered key for further improvements on the field, from the possibility of a positive claim of Galactic DM discovery, to search within the neutrino fog and DM astronomy [ 12 , 13 , 14 ] . The CYGNO experiment [ 15 ] , part of the broader CYGNUS proto-collaboration [ 16 ] , aims to employ a directional detector for rare event searches such as DM direct detection. Its concept consists in a Time Projection Chamber (TPC) filled with a He:CF 4 gas mixture at room temperature and atmospheric pressure with an amplification stage based on Gas Electron Multiplier (GEM) [ 17 ] technology. GEM detectors are transparent to the light generated in the electrons’ avalanches. Thanks to the scintillating properties of the gas [ 18 , 19 ] and to the amplification stage the readout is optical, comprised of scientific CMOS (sCMOS) or quantitative CMOS (qCMOS) cameras and photomultiplier tubes (PMTs). The high granularity of the amplification stage and readout enables precise three-dimensional reconstruction of particle tracks down to few mm while achieving low energy threshold below 1 keV ee (electron equivalent). The collaboration is focusing on the development and construction of the demonstrator detector, CYGNO-04. It will consist of a TPC in back-to-back configuration of 0.4 m 3 of sensitive area with 50x80 cm 2 amplification area. The readout foresees 3 qCMOS cameras and 8 PMTs per side. The design foresees a concentrical structure with external shields of water and copper which contain an internal polymethyl methacrylate (PMMA) gas tight vessel which holds in the sensitive volume. It will be installed in the Hall F at underground laboratories of Gran Sasso (LNGS). The main goals are to prove the scalability of the detector technology and to assess the capability of control and prediction of the background which can provide reliable information on the physics reach of even larger detectors. Due to the latter, the realization of the internal structure of the detector with the least amount of material and with the highest radiopurity is of paramount importance to reduce the internal background contribution. At the same time, the correct electrical and mechanical behavior must be preserved in order to maintain a steady and trustworthy data taking. In this paper, different structures for field cage (FC) and cathode are described, tested and validated. 2 Experimental Setup The detector utilized in the following tests is the Gaseous Imaging Nuclear recoil detector (GIN) built and utilised at the Laboratori Nazionali di Frascati (LNF) of Instituto Nazionale di Fisica Nucleare (INFN) . Its concept is based on the typical CYGNO technology design: a TPC filled with He:CF 4 gas mixture in a 60:40 ratio at atmospheric pressure and room temperature. It features an amplification stage based on a stack of three 50 \mu m GEM and the readout is optical. A sketch of the detector and an isometric view of its internal exploded structure are displayed in Figure 1 . The prototype main body is enclosed in a 3 mm thick aluminum Faraday cage with dimensions of 42 × 40 × 44 cm 3 . Inside the Faraday cage, a gas tight PMMA vessel is positioned centered within with dimensions of 22 × 22 × 30 cm 3 , corresponding to a volume of 14.52 liters. On top of the vessel, a 125 \mu m thick and 2 cm wide ethylene tetrafluoroethylene (EFTE) film serves as a window with high X-rays transparency down to few keV. A mobile source holder is placed above and can house radioactive sources and collimators used for calibration. A movable arm with handle outside the Faraday cage adjusts the position of the source in the longitudinal dimension of the sensitive area of the TPC. On the side of the readout, the PMMA vessel is sealed to a custom printed circuit board (PCB) through screws and O-ring. The PCB is designed to deliver the voltage input to the amplification stage and FC which are located inside the PMMA vessel and to mechanically support the amplification stage. The latter comprises three standard GEMs (50 \mu m thickness, 70 \mu m hole size and 140 \mu m pitch) spaced

Read the complete text