Neutron capture measurement of the 165 Ho at the CSNS Back − - n facility in the resonance energy region

De-Xin Wang, Su-Ya-La-Tu Zhang, Wei Jiang, Rui-Rui Fan, Qi-Wei Zhang, Jie Ren, Jin-Cheng Wang, Guang-Yuan Luan, Xiao-Guang Wu, Bao-Hua Sun, Zhen-Xiang Zhou, Hong-Yi Wu, Zhi-Yang He, Cong-Bo Li, Qi Sun, Xuan Pang, Mei-Rong Huang, Guo Li, Gerile Bao, Xi-Chao Ruan · 2025

Read Neutron capture measurement of the 165 Ho at the CSNS Back − - n facility in the resonance energy region by De-Xin Wang, Su-Ya-La-Tu Zhang, Wei Jiang, Rui-Rui Fan, Qi-Wei Zhang, Jie Ren, Jin-Cheng Wang, Guang-Yuan Luan, Xiao-Guang Wu, Bao-Hua Sun, Zhen-Xiang Zhou, Hong-Yi Wu, Zhi-Yang He, Cong-Bo Li, Qi Sun, Xuan Pang, Mei-Rong Huang, Guo Li, Gerile Bao, Xi-Chao Ruan (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-22965.txt.

Introduction

De-Xin Wang leads a large team of twenty researchers who measured how the isotope holmium-165 captures neutrons at a Chinese neutron source. They used a white neutron beam and a detector that surrounds the sample to catch gamma rays. The study focused on the resonance range, where capture spikes at certain energies.

For eighteen s-wave resonances below one hundred electron volts, they extracted energies and widths with a Bayesian code. The spacing between levels followed the pattern expected for chaotic compound nuclei. Their strength value matched published atlases well, which supports the new data for nuclear records and reactor work.

Catalog record

CREATORDe-Xin Wang, Su-Ya-La-Tu Zhang, Wei Jiang, Rui-Rui Fan, Qi-Wei Zhang, Jie Ren, Jin-Cheng Wang, Guang-Yuan Luan, Xiao-Guang Wu, Bao-Hua Sun, Zhen-Xiang Zhou, Hong-Yi Wu, Zhi-Yang He, Cong-Bo Li, Qi Sun, Xuan Pang, Mei-Rong Huang, Guo Li, Gerile Bao, Xi-Chao Ruan
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-22965

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Neutron capture measurement of the 165 Ho at the CSNS Back − - n facility in the resonance energy region De-Xin Wang, Su-Ya-La-Tu Zhang, Wei Jiang, Rui-Rui Fan, Qi-Wei Zhang, Jie Ren, Jin-Cheng Wang, Guang-Yuan Luan, Xiao-Guang Wu, Bao-Hua Sun, Zhen-Xiang Zhou, Hong-Yi Wu, Zhi-Yang He, Cong-Bo Li, Qi Sun, Xuan Pang, Mei-Rong Huang, Guo Li, Gerile Bao, Xi-Chao Ruan Abstract The neutron capture yield of 165 Ho was measured at the Back-streaming White neutron beam line (Back-n) of the China Spallation Neutron Source (CSNS) using a 4 π \pi BaF 2 Gamma Total Absorption Facility (GTAF). The resonance shapes in the energy range from 1 eV 1\text{\,}\mathrm{eV} to 1.0 keV 1.0\text{\,}\mathrm{k}\mathrm{eV} were analyzed using the Bayesian R-matrix code SAMMY. For 18 s-wave resonances below 100 eV 100\text{\,}\mathrm{eV} , the resonance energy E R E_{R} , neutron width Γ n \Gamma_{n} , and radiative width Γ γ \Gamma_{\gamma} were extracted. The statistical analyses of the resonance parameters show that the nearest-neighbor level-spacing distribution follows a Wigner–Dyson form with mean spacing D 0 = 4.53 ​ ( 3 ) D_{0}=4.53(3) eV, indicating chaotic compound-nucleus behavior. The reduced neutron widths follow the Porter–Thomas χ 2 \chi^{2} distribution with one degree of freedom ( v = 1 v=1 ), consistent with a single entrance channel. The mean radiative width for s-wave resonances was determined to be ⟨ Γ γ ⟩ \langle\Gamma_{\gamma}\rangle = 88.10 ± 1.98 88.10\pm 1.98 meV using the weighted-average technique. From the extracted parameters, the s-wave neutron strength function for 165 Ho was derived to be 10 − 4 ​ S 0 = 2.01 ​ ( ± 0.01 ) 10^{-4}S_{0}=$2.01(\pm 0.01)\text{\,}$ , in excellent agreement with values reported in both the Atlas of Neutron Resonances and ENDF/B-VIII.0 data. PACS numbers 25.70.Pq. Keywords Neutron Capture; Total Absorption Calorimeter; CSNS; 165 Ho(n, γ \gamma ). I Introduction Neutron capture data are indispensable for modern nuclear data evaluations because they constrain reaction models and underpin a wide range of applications, from reactor design to astrophysical nucleosynthesis 1959MossinKotin . For decades, the 197 Au(n, \gamma ) reaction has served as the primary standard, thanks to carefully validated cross-section measurements performed at many laboratories 1988Ratynski ; 2009Carlson ; 2010Massimi ; 2011Lederer . Nevertheless, several studies have suggested that 165 Ho(n, \gamma ) possesses properties that could make it a complementary standard in specific experimental configurations 1973czirr . Holmium shares several favorable features with gold: it exhibits a well resolved and representative prompt- \gamma spectrum following neutron capture 1965Brunhart , its product nucleus has a convenient half-life for offline studies, and, most importantly, it features a pronounced s-wave “black” resonance at 3.9\text{\,}\mathrm{eV} with an exceptionally small scattering ratio ( \Gamma_{n}/\Gamma_{T}=0.025 ) 1976Macklin . Because virtually all incident neutrons are absorbed at this energy, corrections for multiple scattering are minimal, greatly simplifying the absolute normalization of capture yields 1982Alfimenkov . Despite these advantages, the adoption of 165 Ho(n, \gamma ) as a secondary standard has been impeded by the scarcity of high precision capture data below in the resonance region. From the standpoint of nuclear structure physics, new data on 165 Ho(n, \gamma ) are equally compelling. Odd-odd nuclei such as 166 Ho remain a stringent test bed for microscopic approaches shell model calculations, collective models, and the interacting boson framework still face difficulties in reproducing their level schemes and decay patterns 2003Bender . Radiative capture experiments provide resonance energies, neutron widths, and radiative widths that are sensitive to the single particle and collective components of the wavefunction 1967Motz ; 2023Pogliano . At present, reliable experimental information for 165 Ho(n, \gamma ) in the resolved resonance region is very limited, and marked discrepancies persist between evaluations and the few existing measurements 1968Asghar ; 1968Konk , as illustrated in Fig. 1 . Figure 1: (Color online) In the resonance energy region of 165 Ho neutron capture cross section of ENDF/B-0VIII.0 compared with the data from Asghar et al. 1968Asghar and Konks et al. 1968Konk . Recent developments in time-of-flight facilities, high-granularity \gamma detectors, and digital data acquisition systems now make it possible to revisit 165 Ho(n, \gamma ) with substantially improved resolution and statistical precision. The present work therefore reports new neutron capture measurements on 165 Ho with the Gamma Total Absorption Facility (GTAF) 2021Zhang , a 4 \pi \gamma -ray detector array consisting of 40 BaF 2 modules operating at the Back-streaming White Neutron beam line (Back-n) at the China Spallation Neutron Source (CSNS) 2022Luan . Section II details the experimental setup, samples, and associated parameters. Section III outlines the methodology for extracting capture yields from the experimental data. In Section IV, we present the results of the capture yields, including a resonance shape analysis with the R-matrix code SAMMY OakRidgeReport , and statistical properties of the average resonance parameters. Finally, Section V summarizes the conclusions of the present work and its implications for future studies. II Measurement The Back-n facility at the CSNS is a time-of-flight (TOF) facility designed for high-precision neutron-induced reaction measurements 2021Tang ; 2021LiXX . The Back-n facility is located in the opposite direction of the CSNS proton beam and extends about 80\text{\,}\mathrm{m} from the spallation target, providing a broad neutron beam ranging from 0.3\text{\,}\mathrm{eV} to 200\text{\,}\mathrm{MeV} 2021CPCTang ; 2021Hu . After several upgrades, the operating power has now reached 170 kW. The unique countercurrent geometry of the Back-n minimizes the background contribution of forward-scattered particles, enhancing its applicability to low-energy neutron reaction measurements, which are critical for nuclear data studies 2022wang ; 2023ZhangS . The Back-n beamline has two experimental stations, ES#1 and ES#2, located at flight path lengths of 55\text{\,}\mathrm{m} and 76\text{\,}\mathrm{m} , respectively. ES#2, the station for present work, is used for neutron capture experiments and offers a neutron flux of 6.92\times 10^{5}\text{cm}^{-2}\cdot\text{s}^{-1} at the sample position 2021Tang . This flux is distributed over three configurable beam spot sizes— \Phi 20\text{\,}\mathrm{mm} , \Phi 30\text{\,}\mathrm{mm} , and \Phi 60\text{\,}\mathrm{mm} 2019chen . The neutron energy spectrum at ES#2 was characterized using two detection systems: a lithium-silicon (Li-Si) detector based on the 6 Li(n,t) 4 He reaction and a 235 U fission chamber exploiting the 235 U(n,f) reaction 2023chen . A silicon flux monitor (SiMon) located upstream of the sample 20\text{\,}\mathrm{m} continuously monitors beam intensity stability. The SiMon consists of a thin 6 LiF conversion layer coupled with eight silicon detectors arranged outside the beam path, ensuring real-time flux normalization without perturbing the neutron beam 2025chen . The GTAF is a 4\pi array of 40 BaF 2 detectors located at ES#2 (as shown in Fig. 2 ), designed for total‑absorption \gamma -ray spectroscopy 2021Zhang . The array forms a spherical shell comprising 12 pentagonal and 28 hexagonal frustum‑shaped BaF 2 crystals, with an inner diameter of 20 cm and a radial thickness of 15 cm. The energy calibration of each \mathrm{BaF}_{2} detector was conducted using standard \gamma -ray sources, including 60 Co ( 1.173\text{\,}\mathrm{M}\mathrm{eV} and 1.332\text{\,}\mathrm{M}\mathrm{eV} ) and 137 Cs ( 0.662\text{\,}\mathrm{M}\mathrm{eV} ) in the experiment. The signals from each detectors are collected with the XIA digital data acquisition system (DAQ) developed by the Experimental Nuclear Physics Group of Peking University 2020Wu . To prevent the massive amount of experimental data generated by GTAF, the XIA DAQ does not record the waveforms in real-time,

Read the complete text