Impact of Charge Transfer Inefficiency on transit light-curves
S. Mishra, R. Samadi, D. Bérard · 2025
Read Impact of Charge Transfer Inefficiency on transit light-curves by S. Mishra, R. Samadi, D. Bérard (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-22092.txt.
Introduction
Shaunak Mishra, Reza Samadi, and Diane Bérard protect the precision of the PLATO space mission. PLATO will find Earth-sized planets around Sun-like stars. It sizes them by watching them cross their stars. The size target is better than two percent. Radiation damage in the cameras leaves a defect called charge transfer inefficiency. The defect smears recorded light and can shrink the measured dip.
The team worked with simulated star fields from the mission's own simulator. They modeled the defect's lingering signal as a sum of fading exponentials. That identified the trap types involved. Smearing was stripped out column by column. Trap density was mapped across the camera plane. Their correction pulls biased transit depths back inside the accuracy budget. Real planet sizes can then be trusted.
Catalog record
| CREATOR | S. Mishra, R. Samadi, D. Bérard |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 65 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2510-22092
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Impact of Charge Transfer Inefficiency on transit light-curves S. Mishra, R. Samadi, D. Bérard Abstract Context. PLATO is designed to detect Earth-sized exoplanets orbiting solar-type stars and to measure their radii (relative to the star radii) with an accuracy better than 2 % 2\% via the transit method. Charge transfer inefficiency (CTI), a by-product of radiation damage to charge-coupled devices (CCD), can jeopardise this accuracy constraint and therefore must be corrected to reach scientific requirements. Aims. We assessed and quantified the impact of CTI on transit depth measurements. Our objective was to motivate the need for CTI correction and to develop a correction strategy that restores CTI-biased transit depths with an acceptable residual within the accuracy budget. Methods. Using a calibration dataset generated with PLATOSim to simulate a realistic stellar field, we modelled the parallel overscan signal as a sum of exponential decays and used least-squares fitting to infer the number of trap species and initial estimates for the release times τ r , k \tau_{\mathrm{r,k}} . Smearing was then modelled with an exponential-plus-constant function and removed on a column-wise basis. We modelled the spatial variation in the trap density with a quadratic polynomial function of the radial distance from the centre of the focal plane. The polynomial coefficients a p , k a_{p,k} of this model, the well-fill power index β \beta , and the release times τ r , k \tau_{\mathrm{r,k}} were subsequently adjusted via an iterative application of the Extended pixel Edge Response (EPER) method combined with a CTI correction algorithm. This yielded the final calibration model that underpins our correction strategy. Results. In the worst-case scenario (8-year mission, high CTI impact zone), we found that CTI induced a bias of approximately 4 % 4\% in the measured transit depth. The polynomial coefficients from our trap density model were then used to correct the CTI-affected transit depths. Our correction reduced the bias to a residual of 0.06 % 0.06\% , comfortably within PLATO’s accuracy requirements. Conclusions. We quantified the CTI-induced bias in transit depth measurements and implemented a calibration strategy that incorporates spatial variations in trap density. From the calibrated parameters, we derived a correction scheme that brought the photometric measurements within PLATO’s noise budget, ensuring that the mission’s precision requirements are met. A correction strategy for PLATO 1 Introduction PLATO (PLAnetary Transits and Oscillations of stars) is ESA’s M3 mission scheduled for launch in late 2026. PLATO aims to detect and describe exoplanets and conduct asteroseismological studies of the host and observed stars. Specifically, it will identify Earth-sized exoplanets (radius ¡ 2R_{Earth} ), orbiting F5-K7 dwarf and sub-giant stars (magnitude \lesssim\penalty\ 11 ), with a particular focus on terrestrial planets located in the habitable zone of solar-type stars. Thus, it will offer critical insights about planet formation, existence of comparable solar systems and potentially habitable planets ( Rauer et al. 2025 ) . PLATO will conduct high precision photometric observations to identify these planets via the transit method. According to PLATO’s accuracy requirements, the planet-to-star radius ratio for an Earth-sized planet orbiting a G0V star of m_{V}=10 (goal m_{V}=11 ) must be determined with an accuracy better than 2\% ( PLATO Science Working Team 2019 ) . This noise budget has to be shared among different sources of systematic error. However, as we will show in the present work, meeting these precision requirements will be challenging because the space environment can damage the charge-coupled devices (CCD) that enable the observations. The payload’s exposure to radiation will induce defects in the CCD, creating charge-trapping sites that intermittently capture and release electrons. This deferred charge release causes flux loss outside the aperture mask and degrades photometric observations. This phenomenon, known as charge transfer inefficiency (CTI), affects the quality of light-curves used to extract transit depths and, consequently, introduces measurement errors. While PLATO’s noise budget does not explicitly allocate CTI, the consortium’s internal reference value for sky background noise ( 0.4\% ) serves as the benchmark threshold for CTI mitigation. Modelling and assessing the impact of CTI on astrophysical applications has been carried out for missions such as Euclid and FLEX (scheduled for launch in 2026) ( Israel et al. 2015 ; Bernard et al. 2021 ) . For Euclid’s CCD detectors, a CTI correction pipeline called ArCTIC, built on the Pyxel framework ( Arko et al. 2022 ) , has been developed ( Kelman et al. 2022 ; Kelman et al. 2024 ) . While these existing methods rely on robust frameworks, they do not account for the spatial variation in trap density across the detector for each species. Ignoring such spatial variations may bias correction accuracy in real missions. Our work incorporates the spatially varying nature of trap density, which is anticipated for PLATO. To our knowledge, this is the first quantitative demonstration of CTI impacting exoplanet transit measurements. Although our study focuses on PLATO, the calibration and correction strategy presented here is broadly applicable to any detector system affected by CTI, providing a general framework for restoring CTI-impacted transit depths and preserving photometric accuracy. To motivate the need for CTI mitigation, we quantify the CTI-induced bias in the transit depth measurement of an Earth-sized exoplanet transiting a solar-type star in the context of PLATO’s accuracy requirements (Sect. 2 ). We present our CTI calibration strategy in Sect. 3 . CTI is modelled using the Charge Density Model (CDM; Short et al. 2013 ; Massey et al. 2014 ), based on the Shockley–Read–Hall theory ( Shockley & Read 1952 ; Hall 1952 ; Hardy et al. 1998 ) . The CDM depends on the mean trap density ( n_{\mathrm{t}} ), release time ( \tau_{\mathrm{r}} ), well-fill power index ( \beta ), capture cross-section ( \sigma ), and operating temperature. To extend CDM beyond its uniform mean trap density assumption, we adopt a trap density distribution, incorporating an axisymmetric radial dependence inferred from the radiation map in OHB System AG 2024 . The calibration proceeds in three stages: (1) initial iterative estimates of trap release times, (2) a non-iterative smearing correction via least squares, and (3) an iterative fit of the polynomial coefficients of the trap density model, well-fill power-law index \beta , and the release times via an algorithm involving the Extended pixel Edge Response (EPER) method combined with the Massey et al. 2014 CTI correction algorithm. Section 4 outlines our CTI correction strategy, adapted from the iterative inversion algorithm of Massey et al. 2014 and relying on the CTI parameters obtained from our calibration procedure. We evaluate the performance of this correction scheme, demonstrating its ability to recover CTI-affected transit depths toward their true values. Finally, Sect. 5 summarises the findings, highlights the limitations of the calibration–correction framework, and discusses the assumptions underlying our approach. 2 CTI and its impact on transit depth 2.1 The PLATO instrument and the photometric measurements The PLATO payload consists of 26 cameras: 24 “normal” cameras operating in white light for high-precision photometry, and 2 “fast” cameras providing colour information in the blue (505–700 nm) and red (665–1000 nm) bands ( Marchiori et al. 2019 ) . Each camera hosts four CCD detectors at its focal plane. About 80\% of PLATO targets will have on-board photometry extracted using fixed aperture masks.