AutoVARP – A framework for automated reproducible inducibility testing in computational models of cardiac electrophysiology

Paolo Seghetti, Matthias A. F. Gsell, Anton Prassl, Martin Bishop, Gernot Plank · 2025

Read AutoVARP – A framework for automated reproducible inducibility testing in computational models of cardiac electrophysiology by Paolo Seghetti, Matthias A. F. Gsell, Anton Prassl, Martin Bishop, Gernot Plank (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-18635.txt.

Introduction

Paolo Seghetti and his four co-authors present a framework for testing, inside a computer model of the heart, whether a dangerous rhythm can be triggered. Such virtual inducibility studies could one day guide real treatment, but the field suffers from results that others cannot reproduce and from procedures that vary from lab to lab. Their framework, AutoVARP, standardizes the whole study through shareable input files, built on open simulation tools.

A study runs in four stages: preparation pacing, steady-state pacing, induction attempts with extra stimuli, and a check of whether any triggered rhythm sustains itself. The authors demonstrated the framework on a large cohort of virtual subjects, where it exposed numerical artifacts caused by careless setups, and on a detailed two-ventricle heart mesh. Their aim is a shared, repeatable standard for a technique moving toward clinical use.

Catalog record

CREATORPaolo Seghetti, Matthias A. F. Gsell, Anton Prassl, Martin Bishop, Gernot Plank
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE71 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-18635

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

AutoVARP – A framework for automated reproducible inducibility testing in computational models of cardiac electrophysiology Paolo Seghetti, Matthias A. F. Gsell, Anton Prassl, Martin Bishop, Gernot Plank Abstract Background and Objective: Simulations of cardiac electrophysiology (CEP) are gaining momentum beyond basic mechanistic studies, as an approach for supporting clinical decision making. The potential for in silico technologies observed from the research community is immense, with studies demonstrating significantly improved therapeutical outcome with little to no additional burden for patients. Studies replicating virtually induction protocols in post myocardial infarction patients are among the most reproduced and promise to identify non invasively ablation targets for therapeutical intervention. Two main factors hinder the translation of these technologies from pure research to applications: virtually no reproducibility of results, and lack of standardized procedures. Inspired by a previously published virtual induction study by Arevalo et al. (2016), We address the issues of reproducibility and standardization providing auto-VARP , a framework for standardization of virtual arrhythmia inducibility studies, built upon openCARP and the carputils framework. Methods and Results: Standardization relies on the previously published forCEPSS framework and is ensured by defining the whole induction study with input files that can be easily shared to ensure reproducibility since the whole pipeline relies on open software. Our approach also ensures numerical efficiency by separating the induction study into four stages: (i) pre-pacing with forCEPSS, (ii) S1 pacing tor each steady state, (iii) S2 induction with different extrastimuli, (iv) testing of sustenance of induced reentries. We demonstrate the approach in a large virtual subject cohort to investigate numerical artifacts that may arise when improper setups are provided to perform virtual induction, and additionally showcase auto-VARP in a biventricular mesh. Conclusions: auto-VARP addresses effectively the current gap in standardization and reproducibility of results providing a uniform methodology that can be implemented even by non expert users. auto-VARP is highly scalable and adaptable to markedly different anatomies. Although less flexible than in house implementations it provides automated tools to share setups and does not require re-implementation of any process. [ orcid=0000-0001-7511-2910] [ orcid = 0000-0001-7742-8193 ] [ orcid = 0000-0001-7742-8193 ] [ orcid = 0000-0001-7742-8193 ] [ orcid =0000-0002-7380-6908 ] † † highlights: Open-source framework for standardizing inducibility studies in virtual hearts High-level abstraction and workflow automation simplifies study execution and reduces user errors Efficient implementation of the induction protocol by staged execution Facilitates verification of studies by reproduction due to reliance on freely available software openCARP and carputils keywords openCARP ,Standardized workflow ,Cardiac electrophysiology ,Ventricular tachycardia , † † credit: Writing - Original draft preparation, Methodology, Software † † credit: Resources, Data curation † † credit: Resources, Data curation † † credit: Conceptualization of this study, Methodology † † credit: Conceptualization of this study, Writing - Original draft preparation, Methodology, Software 1 Introduction Computational models of CEP offer a unique approach for gaining mechanistic insight into cardiac function in health and disease niederer2019:_models_cardiol . More recently, their scope has started to expand beyond basic research, with applications geared towards medical device development swenson20:_atp in industry, or even towards supporting clinical decision making azzolin_personalized_2023 ; corral-aceroDigitalTwinEnable2020 . An important class of clinical applications is the creation of patient-specific models, often referred to as cardiac digital twins (CDTs) baghirath24:_digital_twin , for testing the inducibility of cardiac arrhythimas sung22:_inFAT . A specific point in case are CDTs of patients surviving myocardial infarction (MI) where the outcome of virtual inducibility tests is used to stratify their risk of suffering from a Ventricular Tachycardia (VT) arevalo16:_varp or tailor VT ablation therapies by guiding ablation targeting prakosa18:_vaat in the real patient. While conceptually appealing, the realization of such in silico studies poses a number of major technical challenges. First, the implementation of virtual inducibility testing studies based on protocols that mimic procedures used in the clinic for inducing a VT in a patient constitutes a complex task. Typically, this involves the definition of physiological parameters and their spatial heterogeneity, the selection of anatomical locations from where pacing stimuli are delivered, a stimulation protocol to define a limit cycle as an initial condition, a perturbation protocol for testing whether or not a VT can be induced, and a suitable analysis over an observation period to determine whether the VT is sustained, is similar to the clinical VT , as well as the identification of VT circuits and critical segments of the path such as infarct isthmus exit sites ciaccioVentricularTachycardiaSubstrate2025 . When executing such a study, a large number of simulations must be performed and simulated outputs must be analyzed in a post-processing steps to automatically extract features and evaluate these against clinical criteria. A sound implementation of such protocols, typically performed by individual specialized labs, is a demanding, time-consuming, non-standardized and error prone endeavor that requires significant expertise beyond CEP in simulation engineering. Owing to the large number of required simulations and the vast parameter space to sweep, a high level of processing automation is key to keep simulation workflows tractable in terms of computational efficacy, robustness, and speed with minimal to no interactive processing. Further, all processing steps and the used options must be encoded an audit trail to facilitate reproduction of a study. However, as the implementation of such protocols are often not shared nor made publicly available, scrutiny and reproduction is limited to the reporting laboratory. As such, an independent external assessment of the findings of a study, whether for validation or falsification, remains unfeasible. In this work we address this need for a standardized implementation of an in silico inducibility testing protocol by providing an implementation of the Virtual Arrhythmia Risk Prediction (VARP) protocol arevalo16:_varp . Our implementation of the VARP protocol, referred to as auto-VARP , has been abstracted, highly automated, and generalized to be most broadly applicable and optimized for efficiency to facilitate automated inducibility testing on large virtual cohorts, with an arbitrary number of pacing sites under flexible definitions of the stimulation protocol. The auto-VARP pipeline is implemented in Python building upon the carputils framework plank21:_opencarp , using the standardized forCEPSS tools for determining experimental limit cycles gsell24:_forcepss . The auto-VARP simulation management is tailored for openCARP , which is compatible with simulation tools vigmond08:_solvers used in published studies using the VARP protocol. Post-processing and visualization builds upon the tools Meshtool neic20:_meshtool and Meshalyzer, both included within the openCARP framework. The auto-VARP implementation further supports the openCARP bundle feature to simplify usage and reproduction. The entire auto-VARP implementation is freely available along with all simulation and processing tools, thus ensuring a seamless reproduction of studies based on the VARP protocol. The execution of a full blown inducibility study using auto-VARP is showcased by replicating a recent VT simulation study which observed model-dependent stochastic effects with the VARP protocol bishop25:_stochastic . 2 Methods Figure 1: Outline of auto-VARP workflow. A cohort of subject-specific anatomical meshes with appropriate labeling is provided, along with definitions of subject-specific pacing locations and electrophysiological properties characterizing normal healthy myocardium, and impaired border zone tissue (left panels). The VARP inducibility test is executed for each subject in a staged workflow comprising a pre-pacing (PP) stage to compute a limit cycle as a reference condition, a S1 stage to stabilize the activation sequence to a prescribed PCL ,

Read the complete text