Energy-based interpretation of the dispersion coefficient of the constant phase element

Anis Allagui ∗, Enrique H. Balaguera, Ahmed Elwakil · 2025

Read Energy-based interpretation of the dispersion coefficient of the constant phase element by Anis Allagui ∗, Enrique H. Balaguera, Ahmed Elwakil (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-17812.txt.

Introduction

Anis Allagui, Enrique H. Balaguera, and Ahmed Elwakil give physical meaning to a puzzling fitting number. The number is the dispersion coefficient of the constant phase element. That element models imperfect capacitors in impedance spectroscopy data. Analysts usually treat its coefficient as a bare fitting parameter.

The team links the coefficient to energy stored or lost in the element. They split input energy into capacitive storage and resistive loss parts. Three test inputs were checked: constant, ramp, and quadratic voltages. In every case, energy ratios reduced to functions of that coefficient alone. The result grounds the coefficient in energy terms for device analysis.

Catalog record

CREATORAnis Allagui ∗, Enrique H. Balaguera, Ahmed Elwakil
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE27 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-17812

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Energy-based interpretation of the dispersion coefficient of the constant phase element Anis Allagui ∗, Enrique H. Balaguera, Ahmed Elwakil Abstract The dispersion coefficient of the constant phase element (CPE) is typically treated as an empirical fitting parameter in the analysis of impedance spectroscopy data, with no clear physical meaning. Here we seek to establish a energy-based interpretation for this coefficient by linking it to the ratio of the dissipated or stored energy in the CPE relative to that supplied by the input source. Using the R ​ C RC network equivalency of a CPE, we decompose the total input energy into a contribution stored in the capacitive modes and another dissipated in the resistive modes. Analytical expressions are derived for three test examples: (i) a constant voltage, (ii) a voltage ramp, and (iii) a quadratic input of the form v ⁡ ( t ) = λ ​ t 2 v(t)=\lambda t^{2} . In all cases we found that the ratios of any two of these energy quantities reduce to pure functions of the dispersion coefficient of the CPE, independent of excitation amplitude or material parameters. This result provides a new perspective of the CPE’s dispersion coefficient from a thermodynamic/energetic basis, with direct implications for supercapacitor characterization, battery modeling, as well as for the analysis of other electrochemical systems and devices exhibiting the CPE behavior. I Introduction The constant phase element (CPE) is undeniably a standard tool regularly used for the analysis and interpretation of impedance spectroscopy data of practically most real electrochemical interfaces Gateman et al. 2022 . Numerous origins have been proposed for the non-ideal behavior of the CPE, including (i) roughness, porosity and fractal morphology of the electrode surface, (ii) non-uniform distribution of double-layer capacitance and charge transfer resistance at the electrode/electrolyte interface, as well as (iii) chemical heterogeneities resulting from adsorption or solution impurities Gateman et al. 2022 ; Lasia 2022 ; Córdoba-Torres et al. 2015 . However, despite the considerable efforts that have been invested in the experimental and theoretical studies of systems exhibiting the CPE behavior, a clear physical meaning of the element and its parameters is still clouded and ill-defined Córdoba-Torres et al. 2015 ; Lasia 2022 . We recall that the CPE is defined from its impedance function \tilde{z}(s)={1}/({c_{\alpha}s^{\alpha}}) where \alpha\;(0<\alpha<1) is known at the dispersion coefficient of the CPE, c_{\alpha} as a pseudocapacitance (positive) constant in units of F s α-1 , and s^{\alpha} is equal to \omega^{\alpha}(\cos(\alpha\pi/2)+j\sin(\alpha\pi/2)) . The impedance, having both its real and imaginary parts non-zero, makes the CPE a lossy capacitor that sits between the ideal capacitor and the resistor. The phase angle is \phi(\tilde{z})=-\alpha\pi/2 , constant and independent from frequency, which is why it is called a CPE. The specific case of impedance when \alpha=1/2 is known as the Warburg element. By integral transform methods, one can carry out the analysis of the CPE behavior in the time domain in terms of voltage, current, and power, which has been done in response to different types and forms of excitations Allagui et al. 2022 ; Allagui et al. 2021 ; Allagui et al. 2024 ; Fouda et al. 2019 . Although this compact formulation of the CPE is invaluable for describing the frequency-dispersed processes in electrochemical systems and devices Bisquert and Balaguera 2025 , that would otherwise require a large number of elementary RC circuits, the lack of clear physical understanding of the parameter \alpha is still a limitation to its broader usage. Figure 1: Schematic diagram representing the different energy metrics in a constant phase element (CPE); the source input energy at a time \tau ( E_{{in}}(\tau) ) is equal to the sum of the stored energy in the capacitive part of the CPE ( E_{s}(\tau) ) and the dissipated energy in its resistive part ( E_{d}(\tau) ). The inset shows an RC equivalent circuit for a CPE consisting an infinite number of series R_{\omega}C_{\omega} branches connected in parallel, wherein each branch contributes with an elemental or modal stored energy e_{\omega}(t) (in the capacitor C_{\omega} ), and generates an elemental dissipated power p_{\omega}(t) (due to the resistor R_{\omega} ) The purpose of this work is to propose an energy-based interpretation of the dispersion coefficient \alpha of a CPE. This is carried out by splitting the input energy into a contribution that is stored in the capacitive parts of the CPE and another that is dissipated in its resistive parts using the RC network equivalency. In particular, we show that in response to an applied constant voltage, the value \alpha is found to be proportional to the natural logarithm of the input-to-dissipated energy ratio. For the case of a dynamic excitation by a voltage ramp or a voltage v(t)\propto t^{2} , the coefficient \alpha is also found to follow a function of the same energy fraction (but more complex than the step voltage case), without the involvement of any other parameters such as the pseudocapacitance c_{\alpha} or the magnitude of the voltage scan rate or the duration of the excitation, or others. The CPE coefficient \alpha is therefore not just an empirical fitting parameter in the study of spectral impedance data, but an index that represents the tradeoff between the dissipated and stored energies in response to a given input energy. The results are expected to have broad implications for the analysis of porous electrodes in supercapacitors, batteries, fuel cells and other devices exhibiting the CPE type of response. II Theory II.1 Current-voltage relationship The time-domain current-voltage relationship for a CPE is given by the Caputo time-fractional derivative: i(t)=c_{\alpha}\,{}_{0}\text{D}_{t}^{\alpha}v(t) (1) The Caputo differential operator {}_{0}\text{D}_{t}^{\alpha}f(t) of order \alpha ( m-1<\alpha\leqslant m , m\in\mathbb{N} ) of a function f(t) is defined starting from its representation in the Laplace domain by Podlubny 1998 : \mathcal{L}\left[{}_{0}\text{D}_{t}^{\alpha}f(t);s\right]=s^{\alpha}\tilde{f}(s)-\sum\limits_{k=0}^{m-1}s^{\alpha-k-1}f^{(k)}(0^{+}) (2) where f^{(k)}(t) is the k^{\text{th}} derivative of f(t) with respect to t . This leads to the definition of the Caputo fractional derivative as Podlubny 1998 : {}_{0}\text{D}_{t}^{\alpha}f(t)=\frac{1}{\Gamma(m-\alpha)}\int_{0}^{t}(t-\tau)^{m-\alpha-1}f^{(m)}(\tau)d\tau (3) for m-1<\alpha<m . For \alpha=m , we retrieve the standard integer-order derivative {d^{m}f(t)}/{dt^{m}} . When a voltage v(t) is applied onto the CPE, the current i(t) is obtained directly from Eq. 1 , and when a current i(t) is applied, the resulting voltage v(t) can be found from the inverse Laplace transform of \tilde{z}(s)\,\tilde{i}(s) as: v(t)=\mathcal{L}^{-1}\left[\tilde{z}(s)\,\tilde{i}(s);t\right]=\frac{1}{c_{\alpha}\Gamma(\alpha)}\int_{0}^{t}(t-\tau)^{\alpha-1}i(\tau)d\tau (4) From these two quantities, it is straightforward to obtain the impedance of the CPE, \tilde{z}(s)={1}/({c_{\alpha}s^{\alpha}}) , from the ratio of the Laplace transform of the voltage by that of the current. II.2 Input, dissipated and stored energies The instantaneous power input p(t) that goes into a CPE from an external power supply is given by the point-wise product of the voltage by the current in the time domain (see Fig. 1 ) as: p(t)=v(t)i(t)=c_{\alpha}\,v(t)\,{}_{0}\text{D}_{t}^{\alpha}v(t) (5) from which the total energy up to a time \tau is given by the integral: E_{\rm in}(\tau)=\int_{0}^{\tau}v(t)i(t)dt (6) In order to account for the portion of this energy that is effectively stored by the capacitive part of the CPE and the portion that is irreversibly dissipated by its resistive part (see Fig. 1 ), the power p(t) in Eq. 5 is re-formulated in terms of the infinite state approach as follows Hartley et al. 2015 ; Trigeassou et al. 2012 ; Trigeassou et

Read the complete text