Energy calibration of bulk events in the BULLKID detector

M. Folcarelli e1,addr1,addr2, D. Delicato addr7,addr1,addr2, A. Acevedo-Rentería addr5, L. E. Ardila-Perez addr9, L. Bandiera addr6, M. Calvo addr7, M. Cappelli addr1,addr2, R. Caravita addr10, F. Carillo addr4, U. Chowdhury addr7, D. Crovo addr9, A. Cruciani addr2, A. D’Addabbo addr8, M. De Lucia a · 2025

Read Energy calibration of bulk events in the BULLKID detector by M. Folcarelli e1,addr1,addr2, D. Delicato addr7,addr1,addr2, A. Acevedo-Rentería addr5, L. E. Ardila-Perez addr9, L. Bandiera addr6, M. Calvo addr7, M. Cappelli addr1,addr2, R. Caravita addr10, F. Carillo addr4, U. Chowdhury addr7, D. Crovo addr9, A. Cruciani addr2, A. D’Addabbo addr8, M. De Lucia a (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-17423.txt.

Introduction

BULLKID is a cold silicon detector built to hunt for light dark matter particles and to catch neutrinos scattering off atomic nuclei. M Folcarelli, leading a team with forty-one co-authors, reports on how the detector energy scale is set for events that happen deep inside its silicon dice, rather than at the surface. Earlier checks used bursts of light, which stop within a hair of the surface.

The team instead used gamma rays from an americium source, which pass through the bulk of each die and better mimic a real dark matter hit. The measured peak stayed close to the light based calibration, and its sharpness doubled when signals from neighbouring dice were combined. Folcarelli and the large team take this as confirmation for the planned dark matter search.

Catalog record

CREATORM. Folcarelli e1,addr1,addr2, D. Delicato addr7,addr1,addr2, A. Acevedo-Rentería addr5, L. E. Ardila-Perez addr9, L. Bandiera addr6, M. Calvo addr7, M. Cappelli addr1,addr2, R. Caravita addr10, F. Carillo addr4, U. Chowdhury addr7, D. Crovo addr9, A. Cruciani addr2, A. D’Addabbo addr8, M. De Lucia a
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE21 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2510-17423

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Energy calibration of bulk events in the BULLKID detector M. Folcarelli e1,addr1,addr2, D. Delicato addr7,addr1,addr2, A. Acevedo-Rentería addr5, L. E. Ardila-Perez addr9, L. Bandiera addr6, M. Calvo addr7, M. Cappelli addr1,addr2, R. Caravita addr10, F. Carillo addr4, U. Chowdhury addr7, D. Crovo addr9, A. Cruciani addr2, A. D’Addabbo addr8, M. De Lucia addr3,addr4, G. Del Castello addr2, M. del Gallo Roccagiovine addr1,addr2, F. Ferraro addr8, S. Fu addr8, R. Gartmann addr9, M. Grassi addr4, V. Guidi addr11,addr6, D. Helis addr8, T. Lari addr3,addr4, L. Malagutti addr6, A. Mazzolari addr11,addr6, A. Monfardini addr7, T. Muscheid addr9, D. Nicolò addr3,addr4, F. Paolucci addr3,addr4, D. Pasciuto addr2, L. Pesce addr1,addr2, C. Puglia addr4, D. Quaranta addr1,addr2, C. M. A. Roda addr3,addr4, S. Roddaro addr3,addr4, M. Romagnoni addr6, G. Signorelli addr3,addr4, F. Simon addr9, A. Tartari addr4, E. Vázquez-Jáuregui addr5, M. Vignati addr1,addr2, K. Zao addr8,addr13 Abstract BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass ≲ 1 \lesssim 1 GeV/c 2 , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV γ \gamma -ray generated by an 241 Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is 5 % ​ ( σ ) 5\%~(\sigma) and its position is shifted by less than 10 % 10\% with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search. ∎ 1 1 1 e-mail: [email protected] (corresponding author) 1 Introduction BULLKID Angelo_BULLKID ; Delicato ; Germanium is a monolithic array of dice of 5.4\,\times\,5.4\,\times 5.0~\text{mm}^{3} carved in a silicon crystal and sensed by phonon-mediated cryogenic Kinetic Inductance Detectors (KIDs) KID ; Swenson ; Moore ; Casali:2015bhk ; Casali:2017yro ; Cardani:2018krv ; Calder . It is designed for the detection of sub-keV energy depositions from particle interactions within the crystal, making it suitable for direct Dark-Matter (DM) searches DM ; WIMP ; CRESST ; CRESST2019 ; TESSERACT ; SuperCDMS and coherent elastic neutrino-nucleus scattering (CE \nu NS) CEvNS ; CEvNS2 ; NUCLEUS experiments. One of the main challenges in this low-energy regime is the energy calibration, which is currently performed with a method based on bursts of 400 nm optical photons Cardani:2018krv ; Lantern . These photons produce electron recoils near the surface of the crystal, unlike DM or CE \nu NS interactions, which produce nuclear recoils uniformly throughout the crystal volume (bulk events). Validating this optical calibration method, using bulk events from particle interactions, is thus of critical importance to confirm the detector’s performance under realistic conditions. In this work, we present such a validation by reconstructing the 59.5 keV \gamma -ray peak from a radioactive 241 Am source using a BULLKID detector. These \gamma -rays are energetic enough to penetrate the entire crystal, with an absorption length \lambda_{\text{abs}} of 13 mm XCOM — defined as the distance over which a photon has a 1-1/e probability of being absorbed. In contrast, optical photons are almost entirely absorbed at the surface, with an absorption length of approximately 82 nm Opt_abs_Si . The measurement presented in this work checks the reliability of the optical calibration technique and allows the investigation for different responses between bulk and surface events. 2 Experimental setup Figure 1: Top: silicon wafer of BULLKID. It is made of 60 silicon dice of 5.4\times 5.4\times 5~\text{mm}^{3} and 0.34~\text{g} each. It is installed in a copper holder for the mechanical stacking and the thermalization at cryogenic temperatures; Center: picture of the wafer (from the side of the lithography) and map of its working KIDs. The resonators inside the orange continuous line represent the acquired KIDs when the main resonators 46,47,49 , in the green boxes, trigger. The empty cells represent missing KIDs while the colorscale is representative of the total quality factor of each resonator. Bottom: scheme (not in scale) of the aluminum pot (light grey) that hosts the BULLKID detector (dark grey) and of the screw with the Americium source on its head. On the top of the aluminum pot, a sketch of the optical fibers used for the illumination of the main KIDs. Figure 2: Schematic representation of a 59.5 keV \gamma -ray emitted from a radioactive 241 Am source interacting within BULLKID. The plot on the right shows the interaction probability, evaluated through a GEANT4 GEANT4:2002zbu simulation, of such \gamma -rays as a function of the depth in the silicon crystal. The depth origin is referenced from the top of the common disk of the structure, as the radioactive source is positioned on the lithography side. Athermal phonons (red dots) generated by the \gamma -ray interaction are predominantly collected by the KID located on the corresponding die. A fraction of these phonons leaks through the common disk into adjacent dice, inducing signals in their respective KIDs. For reference, the light bulb represents the optical fiber, used for the optical calibration, that shines the side of the die opposite to the lithography. The BULLKID detector exploited in this measurement consists in a monolithic silicon wafer, 3 inches in diameter and 5~\text{mm} thick, carved in 60 dice of 0.34 g each (Figure 1 Top). The carvings leave intact a 0.5~\text{mm} thick common disk that acts as both the holding structure of the array and as substrate for the aluminum lithography of the KIDs Angelo_BULLKID . Figure 1 (center) shows a picture of the detector lithography and a map of its resonators. We identify a total number of 57 working KIDs out of 60, due to fabrication issues, with a median quality factor Q of 120 k. For operation, the wafer is installed in a copper holder by clamping the crystal in the peripheral region of the wafer (Figure 1 Top) and placed inside aluminum and Cryophy® pots for shielding from thermal radiation and external magnetic fields. The system is anchored to the coldest point of a dry 3 He/ 4 He dilution refrigerator with base temperature of 20 mK. Additionally a lead castle around the cryostat is built in order to shield from the external radioactivity. The energy of a particle interacting in a die is converted to athermal phonons (Fig. 2 ) that, in part, are absorbed by the KID or by non-sensitive elements, e.g. the feedline. The absorption in the KID leads to a phase shift in the resonator’s transfer function which, for small phase variations, is proportional to the deposited energy Zmuidzinas : \Delta\phi\propto Q\cdot\Delta E (1) As the energy increases, the phase response saturates, introducing a non-linearity in the detector’s response function. The rest of the phonons leak through the common disk in nearby dice and are absorbed by the respective KIDs. In a previous work Angelo_BULLKID , with respect to

Read the complete text