A Way of Axion Detection with Mass 10 − 4 - 10 − 3 10^{-4}\text{-}10^{-3} eV Using Cylindrical Sample with Low Electric Conductivity
Aiichi Iwazaki · 2025
Read A Way of Axion Detection with Mass 10 − 4 - 10 − 3 10^{-4}\text{-}10^{-3} eV Using Cylindrical Sample with Low Electric Conductivity by Aiichi Iwazaki (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2510-16746.txt.
Introduction
Aiichi Iwazaki, in a single-author proposal, describes a way to hunt for axions, a leading dark matter candidate, using a cylinder placed in a strong magnetic field. An axion passing through the field should drive a tiny oscillating electric current in the sample. With a very conductive sample, that current stays at the surface.
Iwazaki instead chooses a material with low conductivity, so the current flows through the bulk of the cylinder and grows with its cross-section. For axions in a low mass range, a large sample gives a signal that can rise above thermal noise even at a few degrees above absolute zero. The paper works out the expected current under a standard axion model.
Catalog record
| CREATOR | Aiichi Iwazaki |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2510-16746
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Way of Axion Detection with Mass 10 − 4 - 10 − 3 10^{-4}\text{-}10^{-3} eV Using Cylindrical Sample with Low Electric Conductivity Aiichi Iwazaki Abstract A dark matter axion with mass m a m_{a} induces an oscillating electric field in a cylindrical sample placed under a magnetic field B B parallel to the cylinder axis. When the cylinder is made of a highly electrically conductive material, the induced oscillating current primarily dissipates the axion energy at the surface. In contrast, if the cylinder is composed of a material with low conductivity, e.g. σ = 10 − 3 eV \sigma=10^{-3}\text{eV} , the axion energy is dissipated mainly inside the bulk of the cylinder. Within the QCD axion model, the dissipated power P P is estimated as P ≃ 2.8 × 10 − 28 W g γ 2 ( L / 100 cm ) ( R / 2 cm ) 2 ( m a / 10 − 4 eV ) ( B / 10 T ) 2 ( 10 / ϵ ) ( ρ a / 0.3 GeVcm − 3 ) P\simeq 2.8\times 10^{-28}\text{W}g_{\gamma}^{2}\left(L/100\text{cm}\right)\left(R/2\text{cm}\right)^{2}\left(m_{a}/10^{-4}\text{eV}\right)\left(B/10\text{T}\right)^{2}\left(10/\epsilon\right)\left(\rho_{a}/0.3\text{GeVcm}^{-3}\right) , with σ = 10 − 3 \sigma=10^{-3} eV, radius R R , length L L , electric permittivity ϵ = 10 \epsilon=10 of the cylinder and axion energy density ρ a \rho_{a} , where g γ ( KSVZ ) = − 0.96 g_{\gamma}(\text{KSVZ})=-0.96 and g γ ( DFSZ ) = 0.37 g_{\gamma}(\text{DFSZ})=0.37 . Using an LC circuit appropriately tuned to a quality factor Q = 10 6 Q=10^{6} , the signal-to-noise ratio at low temperature 100 100 mK and observation time 60 60 sec. is so large ∼ 10 \sim 10 that the detection of dark matter axions is feasible in the mass range m a = 10 − 4 - 10 − 3 eV m_{a}=10^{-4}\text{-}10^{-3}\text{eV} . eprint Nisho-2-2025 A central issue in particle physics is to identify phenomena beyond the Standard Model. The axion, proposed as the Nambu–Goldstone boson of Peccei–Quinn symmetry axion ; axion1 ; axion2 , provides a natural solution to the strong CP problem and is also a well-motivated dark matter candidate. It is called as QCD axion. The viable mass window for the QCD axion is tightly constrained to m_{a}=10^{-6}\mbox{-}10^{-3}\text{eV} Wil ; Wil1 ; Wil2 . Numerous experiments are underway to search for dark matter axions review , most exploiting axion–photon conversion in a strong magnetic field. The induced electromagnetic radiation is expected to be detected with resonant cavities admx ; haystac , superconducting qubits moroi , Quantum Hall effect iwazaki ; aiwazaki , e.t.c. In this letter we propose a new method for axion detection using a cylindrical sample with low electric conductivity, \sigma=10^{-3}\text{-}10^{-2}\text{eV} at low temperature 100 mK. Our target is the mass range m_{a}=10^{-4}\mbox{-}10^{-3} eV, which is difficult to detect with resonant cavity. Dark matter axion generates an oscillating electric field in the presence of a strong magnetic field, which in turn induces an oscillating current in the cylinder. By applying the magnetic field parallel to the cylinder axis, the induced current flows parallel to the external field. In general, such currents are confined within the skin depth \delta . For highly conductive materials, e.g. \sigma=10^{4}\text{eV} , the skin depth is extremely small ( \delta\sim 10^{-5}\text{cm} for m_{a}=10^{-4} eV ), restricting the current to a thin surface layer. As a result, the effective volume occupied by current flow is small, and the dissipated power from Joule heating is very low to be difficult to detect. On the other hand, for a cylinder with low conductivity the induced current flows the bulk, and the resulting dissipated power P becomes large enough to be detectable at low temperatures ( T\sim 100\text{mK} ). We show that P\simeq 2.8\times 10^{-27}\mbox{W}\Big(\frac{L}{100\mbox{cm}}\Big)\Big(\frac{R}{2\mbox{cm}}\Big)^{2}\Big(\frac{B_{0}}{10\mbox{T}}\Big)^{2}\Big(\frac{m_{a}}{10^{-3}\text{eV}}\Big)\left(\frac{10}{\epsilon}\right)\Big(\frac{\rho_{a}}{0.3\rm GeVcm^{-3}}\Big) (1) with \sigma=10m_{a}=10^{-2} eV, where length L=100 cm and radius R=2 cm of the cylinder with electric permittivity \epsilon=10 . The power P depends slightly on \sigma so that even with \sigma=5\times 10^{-3} eV, the power is still large P\simeq 2.2\times 10^{-27}W . Uniquely, the axion–electromagnetic coupling drives an oscillating current that permeates the entire cylindrical sample, in contrast to ordinary electromagnetic induction where currents are confined to the surface at high frequencies. By adopting an appropriate conductivity, e.g. \sigma\sim 5\times 10^{-3}\text{eV} at low temperature \sim 100 mK and radius ( length ) of the cylinder 2 cm ( 100 cm ), we show that using LC circuit tuned with a quality factor Q=10^{6} , dark matter axion can be probed in the mass range m_{a}=10^{-4}\text{-}10^{-3}\text{eV} with large signal-noise ratio \sim 10 . Our method using cylinder with low electric conductivity is also effective for so called, dark photon. The electromagnetic coupling with the dark photon gives rise to similar effect to the one in the axion that oscillating electric current is induced in the whole of cylinder. The main difficulty in detecting axion dark matter lies in its extremely weak coupling to electromagnetic radiation or ordinary matter ( electrons or nucleons ). In particular, the interaction between the axion field a(t,\vec{x}) and the electromagnetic field is described by L_{a\gamma\gamma}=g_{a\gamma\gamma}a(t,\vec{x})\vec{E}\cdot\vec{B}, (2) where \vec{E} and \vec{B} denote the electric and magnetic fields, respectively. The coupling constant is g_{a\gamma\gamma}=g_{\gamma}\alpha/\pi f_{a} , with the fine structure constant \alpha\simeq 1/137 , the axion decay constant f_{a} , and the relation m_{a}f_{a}\simeq 6\times 10^{-6}\text{eV}\times 10^{12}\text{GeV} for the QCD axion model. The model dependent coefficient is g_{\gamma}\simeq 0.37 for the DFSZ model dfsz ; dfsz1 and g_{\gamma}\simeq-0.96 for the KSVZ model ksvz ; ksvz1 . For a classical axion field representing dark matter, the interaction term g_{a\gamma\gamma}a(t,\vec{x}) is extremely small. Assuming that dark matter consists entirely of axions, the local energy density of the dark matter axion is \rho_{d}=m_{a}^{2}\overline{a(t,\vec{x})^{2}}=\frac{1}{2}m_{a}^{2}a_{0}^{2}\simeq 0.3\text{GeV}/\text{cm}^{3}, (3) where the overline denotes time averaging. This yields an effective CP-violating interaction of order g_{a\gamma\gamma}a(t,\vec{x})\sim 10^{-21} , essentially independent of the QCD axion mass. Consequently, the axion-induced electric field in vacuum under an external magnetic field B_{0} is extremely weak, of order \sim g_{a\gamma\gamma}aB_{0} . In this letter we show that, for a cylindrical sample in Fig. 1 with low electrical conductivity, the Joule heating induced by axion dark matter can be large enough to be detectable at low temperatures T\sim 100\text{mK} . In this case, the dissipation occurs throughout the bulk of the cylinder, while for a good conductor with large conductivity, the dissipation is confined to a thin surface layer. We focus on the axion mass range m_{a}=10^{-4}\text{-}10^{-3}\text{eV} , using a cylinder of length L=100\text{cm} , radius R\geq 10/m_{a} , and conductivity \sigma=10m_{a}=10^{-3}\text{-}10^{-2}\text{eV} . In particular, we fix the radius R=2 cm thought out the paper as a practical value. As we show soon later, the condition of \sigma m_{a}=\epsilon maximize the power dissipated inside the cylinder with electric permittivity \epsilon . Such a matter with low conductivity may be realized at low temperatures \sim 100\text{mK} , for instance by using semiconductors with suitable impurity doping. A strong external magnetic field \vec{B}_{0} is applied parallel to the cylinder axis, so that the system is axially symmetric. \vec{B}_{0}=(0,0,B_{0}) in cylindrical coordinates (\rho,\theta,z) , with \rho=0 at the center and \rho=R at the surface of