BladderFormer: A Streaming Transformer for Real-Time Urological State Monitoring
Chengwei Zhou, Steve Majerus, Gourav Datta · 2025
Read BladderFormer: A Streaming Transformer for Real-Time Urological State Monitoring by Chengwei Zhou, Steve Majerus, Gourav Datta (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-24178.txt.
Introduction
Watching bladder pressure in real time helps doctors diagnose urinary tract problems, but older tools lean on hand-built traits and shallow classifiers. Chengwei Zhou and 2 co-authors built BladderFormer, a one-layer streaming transformer for that job. It works on wavelet forms of the raw signal and keeps a cache of past state, so it can judge each moment as data arrives.
Trained on records from ninety-one patients, each with tens of thousands of samples, the model improved accuracy over past methods. It also used less energy and answered faster. The team discusses how to run it on low-power edge chips and microcontrollers for bedside use.
Catalog record
| CREATOR | Chengwei Zhou, Steve Majerus, Gourav Datta |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 24 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2509-24178
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
BladderFormer: A Streaming Transformer for Real-Time Urological State Monitoring Chengwei Zhou, Steve Majerus, Gourav Datta Abstract Bladder pressure monitoring systems are increasingly vital in diagnosing and managing urinary tract dysfunction. Existing solutions rely heavily on hand-crafted features and shallow classifiers, limiting their adaptability to complex signal dynamics. We propose a one-layer streaming transformer model for real-time classification of bladder pressure states, operating on wavelet-transformed representations of raw time-series data. Our model incorporates temporal multi-head self-attention and state caching, enabling efficient online inference with high adaptability. Trained on a dataset of 91 patients with 20,000-80,000 samples each, our method demonstrates improved accuracy, higher energy- and latency-efficiency. Implementation considerations for edge deployment on low-power hardware, such as edge graphical processing units (GPU) and micro-controllers, are also discussed. I Introduction Continuous monitoring and classification of bladder pressure dynamics is a critical enabler for intelligent, closed-loop control in urinary management systems [ 1 , 2 ] . Accurate real-time identification of physiological states such as detrusor overactivity, voluntary voiding, or abdominal interference plays a central role in improving patient outcomes, reducing catheter dependency, and advancing neuroprosthetic solutions [ 3 , 4 ] . These diagnostic decisions rely on precise biosignal interpretation under tight latency and energy constraints—requirements unmet by conventional machine learning models that lack support for on-board, real-time inference [ 5 , 6 ] . Traditional urodynamic classification systems have predominantly relied on hand-engineered features and shallow classifiers such as logistic regression or artificial neural network (ANN) classifiers [ 7 , 8 , 9 ] . Although computationally efficient, these approaches exhibit limited robustness across patient populations and perform poorly when generalized to new signal variations [ 10 , 11 ] . Moreover, they fail to extract rich temporal features from time-varying bladder dynamics and are restricted to single-label classification, limiting their ability to differentiate among multiple physiological bladder states [ 12 , 7 ] . Recent advancements in attention-based deep learning, particularly transformer models, have revolutionized sequential modeling in natural language processing and vision [ 13 , 14 ] . Their application to biomedical time-series analysis—such as ECG arrhythmia detection [ 15 , 16 ] , EEG seizure classification [ 17 , 18 ] , and respiration pattern analysis [ 19 , 20 ] —has shown superior performance in capturing long-range dependencies. Nonetheless, these transformer-based models typically involve multiple stacked layers and operate on long input sequences in batch mode, making them impractical for streaming inference on constrained hardware platforms such as wearable devices or microcontrollers [ 21 , 22 , 23 ] . To bridge this gap, we propose a novel streaming transformer architecture tailored for ultra-low-latency bladder pressure classification. Our approach divides incoming physiological signals into short, fixed-length segments (e.g., 8 samples) and performs self-attention within each segment for fine-grained local integration. To capture longer-term temporal dependencies without introducing recurrence, we augment this with a lightweight context vector caching mechanism that stores pooled embeddings from previous segments. This enables causal attention across time while bounding computation and memory overhead. Unlike recurrent neural networks (RNNs) or long short-term memory (LSTM) models, which rely on persistent hidden states and sequential updates, our model performs parallel attention over current segments and cached past context, avoiding the computational bottlenecks of recurrence. Despite this segment-based processing, real-time performance is retained, as each segment spans only 0.8 seconds of data at a 10 Hz sampling rate. Moreover, the classification task is grounded in clinically validated annotations from expert urologists, where each time sample may belong to multiple overlapping physiological categories: None , Overactivity , Voiding , and Abdominal Activity. This multi-label setting reflects the complex, overlapping nature of bladder dynamics, and is not addressed by prior approaches that simplify the task to binary classification. Our method natively supports multi-label inference while preserving temporal resolution and minimizing energy consumption. The resulting architecture—comprising a single-layer transformer with segment-wise and cross-segment attention—achieves 83.25% classification accuracy, outperforming previous ANN-based methods while remaining deployable on low-power microcontrollers. The low parameter count, shallow depth, and fixed-cost attention ensure real-time inference suitable for wearable or implantable autonomous bladder management systems. II Related Work Early approaches to automated bladder pressure analysis emphasized frequency-domain features and conventional signal processing techniques. Cullingsworth et al. [ 24 ] and Niederhauser et al. [ 25 ] demonstrated that spectral analysis and rhythmic contraction profiling could help stratify patients with lower urinary tract dysfunction, laying important groundwork for automated characterization of detrusor overactivity. Expanding on this direction, Karam et al. [ 5 ] introduced the Context-Aware Thresholding (CAT) algorithm, one of the first published systems for automated urological event detection from single-channel vesical pressure. Their approach combined wavelet-based adaptive thresholding with efficient signal processing to detect bladder voiding contractions with 97% accuracy within 1 second of onset. However, the model supported only binary detection and did not differentiate among multiple event types. The introduction of machine learning methods led to more nuanced classification strategies. Wang et al. [ 8 ] employed manifold learning with dynamic time warping to compare 6-second detrusor pressure (PDET) segments against a library of canonical overactivity patterns, achieving 81.4% accuracy in identifying detrusor overactivity. Hobbs et al. [ 7 ] extended this by evaluating both time-domain and frequency-domain features with support vector machine classifiers. Their results showed that single-channel time-domain features could yield 85.4% sensitivity, while combining three-channel frequency features led to 92.9% specificity. Despite their promise, these methods were limited by their reliance on fixed-length (e.g., 60-second) input windows and their focus on specific event classes, restricting their applicability in low-latency or multi-event settings. Other classical methods using support vector machines and decision trees have also been proposed [ 9 ] , but these typically depend on pre-defined features and static, segment-level classification, lacking temporal modeling capabilities. More recently, Majerus et al. [ 12 ] presented a machine learning pipeline combining lifting wavelet transforms with 16 scalar features processed by a compact 4-layer ANN. Their system achieved 79% accuracy on real-time classification tasks deployed on microcontrollers operating at 10 Hz, illustrating feasibility for embedded applications. However, the model operated on isolated segments, without temporal adaptation across samples, and was constrained to single-label predictions per segment, limiting its utility for overlapping or evolving physiological states. In contrast, our streaming transformer integrates short-range temporal dependencies via self-attention, capturing bladder activity transitions more effectively. III Proposed Method III-A Segment-Level Attention for Local Temporal Modeling Our model operates on fixed-length segments of eight consecutive bladder pressure samples, capturing local temporal dependencies while maintaining bounded computational cost. Unlike recurrent models that require sequential processing, our transformer architecture processes all samples within each segment in parallel, introducing only a 0.8-second buffering delay at 10 Hz sampling. This 8-sample window balances temporal resolution with computational efficiency, capturing typical bladder pressure transients (0.5-1.0 seconds) while enabling real-time urological monitoring. Fig. 1: Architecture of the cross-segment caching mechanism for long-term temporal adaptation with single-layer streaming transformer, incorporating with Multi-Head Self-Attention (MHSA) and multi-layer perceptron (MLP) layers, with key components (Q, K, V) for attention computation. Feature Extraction: Let \mathbf{x}{=}[x_{1},x_{2},\dots,x_{512}]{\in}\mathbb{R}^{512} denote the latest 512 samples stored in a first in first out (FIFO) buffer of scalar bladder pressure values. Each buffer is decomposed using a 5-level Lifting Wavelet Transform with Daubechies-4 wavelets: \text{LWT}_{5}(\mathbf{x})=\{A_{5},A_{4},A_{3},A_{2},A_{1},D_{5},D_{4},D_{3},D_{2},D_{1}\} ,