A Novel Chiroptical Spectroscopy Technique
Jorge Olmos-Trigo, Cristina Sanz-Fernández, Ivan Fernandez-Corbaton · 2025
Read A Novel Chiroptical Spectroscopy Technique by Jorge Olmos-Trigo, Cristina Sanz-Fernández, Ivan Fernandez-Corbaton (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-18006.txt.
Introduction
Jorge Olmos Trigo, Cristina Sanz-Fernandez, and Ivan Fernandez-Corbaton present a new light test for the twist of round objects. Their 2025 letter deals with chirality, where an object and its mirror form differ. The standard test reads how much light each twist of a beam loses, which can be noisy.
Their test reads a set of light traits at any off-forward angle. The new score wipes out noise from non-twisted parts. It does not shift with how much stuff is in the beam or how long the path is. In a mix of both mirror forms, it can tell which form leads.
Catalog record
| CREATOR | Jorge Olmos-Trigo, Cristina Sanz-Fernández, Ivan Fernandez-Corbaton |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 30 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2509-18006
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Novel Chiroptical Spectroscopy Technique Jorge Olmos-Trigo, Cristina Sanz-Fernández, Ivan Fernandez-Corbaton Abstract Chiral objects typically exhibit a different extinction for the two circular polarizations of light. Researchers often detect the chirality of objects by measuring this extinction difference employing Circular Dichroism (CD) spectroscopy. In this Letter, we present a new spectroscopy technique for detecting the chirality of spherical objects based on measuring the Stokes parameters at any non-forward angle. The chirality measure we introduce effectively eliminates achiral background noise and is independent of both the object’s concentration and the optical path length. Notably, when a solution contains both enantiomers of a chiral object, our method can discern which enantiomer predominates. Furthermore, we demonstrate that the technique is robust and verifiable in-situ by measuring the Stokes vector at two different non-forward angles of choice. Chirality refers to the geometric property of objects that cannot be superimposed onto their mirror images. In nature, chirality is ubiquitous; numerous organic molecules, such as glucose, and most biological amino acids, are chiral. In the pharmaceutical industry, chiral specificity is crucial as opposite enantiomers, mirror pairs of chiral molecules, can have vastly different effects on biological systems depending on their handedness Lenz and Knapp 1962 . Enantiomer pairs share the same atomic composition and are indistinguishable when measuring their scalar molecular properties. It is through interactions with other chiral entities that their chirality can be revealed. In nanophotonics, the electromagnetic helicity is the most commonly used chiral entity to unveil the chirality of objects Fernandez-Corbaton et al. 2013 . Circular Dichroism (CD) spectroscopy stands as the most utilized technique to unveil molecular chirality using helicity Barron 2009 ; Adhikari and Orrit 2022 . In a conventional CD setup, the molecular solution is sequentially illuminated with fields of opposite helicities, and the total transmitted power is recorded for each case. The CD signal is then computed by taking the difference between these two power measurements in transmission, the forward direction of the light-scattering system. Despite its widespread commercial use, CD exhibits drawbacks. For instance, if CD = 0 for a given frequency of the incident electromagnetic field, it is indeterminate whether the molecular solution is chiral or not. This ambiguity arises because CD provides only partial information about the chirality of the molecule Barron 2009 . To overcome this limitation and gain more insights into the chiral nature of the molecular solution, researchers typically measure optical rotation (OR), which quantifies the change of the polarization direction when linearly polarized light propagates through a chiral medium. However, both CD and OR are measured in the forward direction, which presents a challenge: the presence of a large achiral background signal that hinders the accuracy and reliability of measurements. Moreover, CD and OR depend on molecular concentration and optical path length, which makes the signature of CD and OR measurements of a given chiral object non-universal. Figure 1: Chiral sphere sequentially illuminated by electromagnetic fields of opposite helicities. Two chiral observables are recorded: Circular Dichroism (CD) in transmission and the Stokes Chirality Measure (SCM) using a Stokes vector measurement. In this Letter, we introduce a novel spectroscopy technique for detecting the chirality of spherical objects based on measuring the Stokes parameters at non-forward angles. The chirality measure that we introduce is universal, and in particular, avoids the achiral background and is independent of the object’s concentration and the optical path length. Additionally, when the solution presents both enantiomers of a chiral object, our polarimetry-based method can discern which enantiomer predominates in the solution. Importantly, we demonstrate that our novel technique is robust, and its accuracy can be experimentally verified in situ by measuring the Stokes parameters at two different non-forward angles of choice. Our findings pave the way to characterize the chirality of objects beyond CD and OR, the current state-of-the-art chiroptical spectroscopy techniques. The setting. — The interaction between the electromagnetic field and a small object, such as most chiral molecules, can be treated in the linear dipolar approximation. This approximation relates a 6x6 polarizability tensor with the incident electric and magnetic fields \{{\bf E}_{\rm{inc}}({\bf r}),Z{\bf H}_{\rm{inc}}({\bf r})\}\in\mathbb{C}^{3} at the position of the object, {\bf r}={\bf r}_{0} , with the induced electric and magnetic dipolar moments, denoted as {\bf p}({\bf r}_{0}) and {\bf m}({\bf r}_{0}) , respectively: \displaystyle\begin{pmatrix}{\bf p}({\bf r}_{0})/\epsilon\\ Z{\bf m}({\bf r}_{0})\end{pmatrix}=\begin{pmatrix}{\overline{\alpha}}_{\rm{ee}}&{\overline{\alpha}}_{\rm{em}}\\ {\overline{\alpha}}_{\rm{me}}&{\overline{\alpha}}_{\rm{mm}}\end{pmatrix}\begin{pmatrix}{\bf E}_{\rm{inc}}({\bf r}_{0})\\ Z{\bf H}_{\rm{inc}}({\bf r}_{0})\end{pmatrix}. (1) Here, all {\overline{\alpha}}_{\rm{ij}} are 3x3 complex-valued tensors, and \epsilon and Z=\sqrt{\mu/\epsilon} denote the electric permittivity and impedance of the surrounding medium, respectively. Note that the electric {\overline{\alpha}}_{\rm{ee}} , magnetic {\overline{\alpha}}_{\rm{mm}} , and chiral {\overline{\alpha}}_{\rm{em},\rm{me}} polarizabilities have dimensions of volume in our formulation. A harmonic time dependence \exp(-\mathrm{i}\omega t) is assumed and suppressed from the notation. The {\overline{\alpha}}_{\rm{ab}} tensors are frequency dependent, as are some other quantities, but we only write such dependence later. At this point, it is very often assumed that the rotationally averaged response of a dipolar object can be approximated by the response of an isotropic dipolar object Tang and Cohen 2010 ; Sersic et al. 2011 ; Scott et al. 2020 . It is important to realize that such an approximation is typically good if and only if such a response is evaluated in the forward direction. At non-forward angles, this approximation generally does not hold. An exception to this rule is a spherical nanoparticle, which is the system we consider in the following derivation. We should also mention that the spherical chiral model, derived by Bohren in 1974 Bohren 1974 , is the most widely used framework for studying chiral light–matter interactions Yokota et al. 2001 ; Canaguier-Durand et al. 2013 ; Hayat et al. 2015 ; Li et al. 2019 ; Klimov et al. 2014 ; Wang and Chan 2014 ; Kamandi et al. 2017 ; Sifat et al. 2022 ; Ali et al. 2023 ; Kim and Park 2022 ; Sadrara and Miri 2023 ; Shi et al. 2020 ; Mohammadi et al. 2023 ; Martínez-Romeu et al. 2024 ; Mohammadi and Tagliabue 2024 ; Golat et al. 2024 ; Tetour et al. 2024 . Given all these considerations, we can express Eq. ( 1 ) as \displaystyle\begin{pmatrix}{\bf p}({\bf r}_{0})/\epsilon\\ Z{\bf m}({\bf r}_{0})\end{pmatrix}=\begin{pmatrix}{\alpha}_{\rm{ee}}{\overline{I}}&{\alpha}_{\rm{em}}{\overline{I}}\\ -{\alpha}_{\rm{em}}{\overline{I}}&{\alpha}_{\rm{mm}}{\overline{I}}\end{pmatrix}\begin{pmatrix}{\bf E}_{\rm{inc}}({\bf r}_{0})\\ Z{\bf H}_{\rm{inc}}({\bf r}_{0})\end{pmatrix}, (2) where {\overline{I}} is the 3x3 identity matrix. For scalars, as is the case, we have used that \alpha_{\rm{em}}=-\alpha_{\rm{me}} because of reciprocity Onsager 1936 . Upon interaction with the incident field, dipoles typically re-radiate. The field scattered by an electric and magnetic dipole can be written in the radiation (far-field) zone as Jackson 1999 {\bf E}_{\rm{sca}}({\bf r})=k^{2}\frac{e^{{\rm i}kr}}{4\pi r}\left[\left(\hat{\mathbf{e}}_{\rm{r}}\times\frac{{\bf p}({\bf r}_{0})}{\epsilon}\right)\times\hat{\mathbf{e}}_{\rm{r}}-\left(\hat{\mathbf{e}}_{\rm{r}}\times Z{\bf m}({\bf r}_{0})\right)\right]. (3) Here \hat{\mathbf{e}}_{\rm{r}} denotes the radial unit vector, k is the wavenumber in the surrounding medium, and r=|{\bf r}-{\bf r}_{0}| denotes the observation distance to the center of the dipolar object. In general, we need to consider the summation of Eq. ( 3 ) for the total number of objects (hereafter denoted by N) dispersed in the solution. However, in the far field, any quadratic form of the scattered field results from an incoherent superposition of the individual contributions of the objects if these are randomly dispersed and do not interact with each other (see pages 461-462 of Ref Jackson 1999 ). This latter setting assumes that the field