Ghost Imaging with Free Electron-Photon Pairs

Sergei Bogdanov †, Alexander Preimesberger †, Harsh Mishra, Dominik Hornof, Thomas Spielauer, Florian Thajer, Max Maurer, Pia Falb, Leo Stöger, Thomas Schachinger, Friedrich Bleicher, Michael S. Seifner, Isobel C. Bicket, Philipp Haslinger · 2025

Read Ghost Imaging with Free Electron-Photon Pairs by Sergei Bogdanov †, Alexander Preimesberger †, Harsh Mishra, Dominik Hornof, Thomas Spielauer, Florian Thajer, Max Maurer, Pia Falb, Leo Stöger, Thomas Schachinger, Friedrich Bleicher, Michael S. Seifner, Isobel C. Bicket, Philipp Haslinger (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-14950.txt.

Introduction

Sergei Bogdanov leads a team of fourteen authors demonstrating ghost imaging with electron-photon pairs in a 2025 physics paper. Ghost imaging forms a picture from correlations between two particles: one interacts with the object but is not spatially resolved, while the other carries the spatial information without ever touching the object. Most demonstrations so far used only photons.

Here the pairs mix a massive, charged electron with a massless, neutral photon, produced through cathodoluminescence inside a transmission electron microscope. A custom free-space setup collects the photons outside the microscope. The team reconstructed images of complex patterns with resolution down to a few micrometers. Pairing the two flagship microscopy particles opens a path toward quantum-enhanced electron imaging methods.

Catalog record

CREATORSergei Bogdanov †, Alexander Preimesberger †, Harsh Mishra, Dominik Hornof, Thomas Spielauer, Florian Thajer, Max Maurer, Pia Falb, Leo Stöger, Thomas Schachinger, Friedrich Bleicher, Michael S. Seifner, Isobel C. Bicket, Philipp Haslinger
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE29 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2509-14950

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Ghost Imaging with Free Electron-Photon Pairs Sergei Bogdanov †, Alexander Preimesberger †, Harsh Mishra, Dominik Hornof, Thomas Spielauer, Florian Thajer, Max Maurer, Pia Falb, Leo Stöger, Thomas Schachinger, Friedrich Bleicher, Michael S. Seifner, Isobel C. Bicket, Philipp Haslinger Abstract Coincidence imaging, also known as ghost imaging, is a technique that exploits correlations between two particles to reconstruct information about a specimen. The particle that relays the spatial information about the object remains completely non-interacting, while the particle used to probe the object is not spatially resolved. While ghost imaging has been primarily implemented on photonic platforms, it becomes particularly intriguing when applied to particles with fundamentally different properties, such as massive, charged electrons and massless, neutral photons, especially considering the role of both particles as cornerstones of highly advanced microscopic platforms. In this work, we investigate coincidence imaging using electron–cathodoluminescence photon pairs generated within a transmission electron microscope. Utilizing a custom-built free-space cathodoluminescence setup, we demonstrate ghost imaging of complex patterns. We are able to obtain a spatial resolution down to 2 µm, paving the way for adaptation of quantum-enhanced imaging techniques from photonic quantum optics to electron microscopy. † † footnotetext: These authors contributed equally to this work. Over the past decades, imaging methods based on electrons have made significant technological progress, particularly in transmission electron microscopy (TEM) Reimer and Kohl 2008 . A TEM is a highly developed instrument that exploits the wave properties of electrons, combined with advanced electron optics, to resolve and analyse structures at the atomic scale Ishikawa et al. 2022 ; Muller et al. 2008 with single atom sensitivity Suenaga et al. 2000 ; Varela et al. 2004 and the potential to map atomic orbitals Löffler et al. 2017 ; Bugnet et al. 2022 . Temporal resolution in the TEM reaches the sub-nanosecond regime via improvements in direct detector technology Llopart et al. 2022 , or further down to femto- and even atto-second timescales with the aid of novel pump-probe schemes Zewail 2000 ; Gaida et al. 2024 ; Baum and Zewail 2007 . Incorporating coincidence counting techniques into the TEM enables, for example, Hanbury-Brown-Twiss type experiments to probe the correlations of cathodoluminescence (CL) photon emission statistics Solà-Garcia et al. 2021 to study excitation pathways Varkentina et al. 2022 and lifetimes Varkentina et al. 2023 ; Yanagimoto et al. 2023 ; Meuret et al. 2016 , opening up many new possibilities for electron-photon studies Abajo et al. 2025 . Furthermore, recent advances have demonstrated the ability to sense single CL photon recoils Preimesberger et al. 2025a and to probe spin dynamics utilizing microwave excitation Harvey et al. 2021 ; Liu et al. 2025 ; Weßels et al. 2022 , with angular sensitivities on the order of 100 prad Jaroš et al. 2024 . Time-correlated measurements between electrons and CL photons have been used to map modes in photonic structures Feist et al. 2022 , measure excitation lifetimes Yanagimoto et al. 2023 ; Meuret et al. 2021 , and distinguish competing CL emission pathways Varkentina et al. 2023 . These combined capabilities identify the TEM as an indispensable tool in fields such as materials science, biology, and fundamental research. Nevertheless, radiation damage remains an issue in electron imaging of beam-sensitive samples Egerton et al. 2004 . Several strategies have been proposed and utilized to mitigate these challenges Chen et al. 2020 . Such approaches enable, among other things, Ångstrom-scale reconstruction of protein structures Nogales and Mahamid 2024 ; Guaita et al. 2022 , by combining information from measurements on multiple copies of the target molecule, which are assumed to be identical. One avenue that holds great potential, but has so far remained largely unexplored, is to adapt imaging techniques from photonic quantum optics Pirandola et al. 2018 ; Moreau et al. 2019 ; Defienne et al. 2024 . Utilizing the quantum properties of photon pairs has allowed researchers to image objects with undetected particles Lemos et al. 2014 ; Zou et al. 1991 , violate the shot noise limit Slussarenko et al. 2017 , or use wavefront shaping to address multiple scattering Yu et al. 2015 , surpassing the performance of classical imaging technologies. With recent advances in quantum electron microscopy Rembold et al. 2025 ; Koppell et al. 2022 ; Kruit et al. 2016 ; Mechel et al. 2021 ; Shiloh et al. 2022 ; Abajo et al. 2025 ; Henke et al. 2025a , such as the first experimental demonstrations of electron-photon entanglement in a TEM Preimesberger et al. 2025b ; Henke et al. 2025b , quantum sensing techniques are now beginning to enter the field of electron microscopy. Coincidence imaging, also known as ghost imaging, is a technique widely used in photonic quantum optics Pittman et al. 1995 ; Bennink et al. 2004 ; D’Angelo et al. 2004 . This method uses correlations between two particles to image a specimen located on the path of one particle, while a spatially-resolved detector collects the other particle, which has never interacted with the object Padgett and Boyd 2017 . A ghost image of the specimen is then formed using coincidence matching between the two particles. Recently, ghost imaging has been adapted to work with massive ion-ion pairs Khakimov et al. 2016 and electron-ion pairs Trimeche et al. 2020 . Working with free electrons, a different form of ghost imaging, known as classical computational ghost imaging, has been demonstrated experimentally in a linear accelerator Li et al. 2018 , and has been the subject of several proposals for TEM Kallepalli et al. 2022 ; Rosi et al. 2024 ; Rotunno et al. 2023 . Nevertheless, quantum ghost imaging, employing entangled electron-photon pairs Preimesberger et al. 2025b capable of reaching a joint momentum and position resolution beyond the limits of classical physics Mancini et al. 2002 , has so far not been implemented for the purpose of sensing complex specimens in two dimensions. The experiment presented herein utilizes the strong spatial correlations present between coherent CL photons and the swift electrons they are emitted from. In contrast to the previous work employing ghost imaging to probe the joint uncertainty relation of position and momentum Preimesberger et al. 2025b , the present study focuses on the use of ghost imaging as a tool for complex image reconstruction, demonstrating the first two-dimensional ghost image formed from the spatial correlations between an electron and its corresponding photon. In the following, we describe the setup and the technique of performing ghost imaging on electron-photon pairs. It is particularly remarkable that the constituents of these pairs are fundamentally different, yet both lie at the forefront of microscopic imaging techniques: the charged, massive, relativistic electron possessing a few-picometer de Broglie wavelength, which is able to probe matter on the atomic scale; and the optical photon, which is easy to guide, coherently manipulate, and efficiently detect. We demonstrate the technique by imaging a feature-rich, two dimensional pattern in the shape of a cat. In order to benchmark the imaging quality, we recorded a ghost image of a standard calibration sample, exhibiting few-micrometer resolution. Figure 1: Experimental setup for electron-photon pair coincidence (ghost) imaging . ( A ) Schematic of a TEM equipped with an electron energy filter (spectrometer). A 200 keV electron beam

Read the complete text