Personalization on a Budget: Minimally-Labeled Continual Learning for Resource-Efficient Seizure Detection

Amirhossein Shahbazinia, Jonathan Dan, Jose A. Miranda, Giovanni Ansaloni, David Atienza · 2025

Read Personalization on a Budget: Minimally-Labeled Continual Learning for Resource-Efficient Seizure Detection by Amirhossein Shahbazinia, Jonathan Dan, Jose A. Miranda, Giovanni Ansaloni, David Atienza (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-13974.txt.

Introduction

Amirhossein Shahbazinia and four co-authors personalize seizure detection in a 2025 medical paper. Reading electroencephalography by expert eye is slow. Automated detectors stumble because each patient's brain signals differ and drift over time. A model that keeps learning helps. Unless it forgets yesterday's patterns while absorbing today's, the classic catastrophic forgetting trap.

Their framework, EpiSMART, uses a size-capped replay buffer with informed sample selection. It deliberately keeps high-uncertainty and seizure-predicted snippets. Old knowledge then survives each update. On the CHB-MIT dataset, it lifted the F1 score by about a fifth over a static trained baseline. That held across patients. It needed only a few minutes of newly labeled data and a handful of updates per day. That is light enough for wearables.

Catalog record

CREATORAmirhossein Shahbazinia, Jonathan Dan, Jose A. Miranda, Giovanni Ansaloni, David Atienza
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE41 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2509-13974

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Personalization on a Budget: Minimally-Labeled Continual Learning for Resource-Efficient Seizure Detection Amirhossein Shahbazinia, Jonathan Dan, Jose A. Miranda, Giovanni Ansaloni, David Atienza Abstract Objective: Epilepsy, a prevalent neurological disease, demands careful diagnosis and continuous care. Seizure detection remains challenging, as current clinical practice relies on expert analysis of electroencephalography, which is a time-consuming process and requires specialized knowledge. Addressing this challenge, this paper explores automated epileptic seizure detection using deep learning, focusing on personalized continual learning models that adapt to each patient’s unique electroencephalography signal features, which evolve over time. Methods: In this context, our approach addresses the challenge of integrating new data into existing models without catastrophic forgetting, a common issue in static deep learning models. We propose EpiSMART, a continual learning framework for seizure detection that uses a size-constrained replay buffer and an informed sample selection strategy to incrementally adapt to patient-specific electroencephalography signals. By selectively retaining high-entropy and seizure-predicted samples, our method preserves critical past information while maintaining high performance with minimal memory and computational requirements. Results: Validation on the CHB-MIT dataset, shows that EpiSMART achieves a 21% improvement in the F1 score over a trained baseline without updates in all other patients. On average, EpiSMART requires only 6.46 minutes of labeled data and 6.28 updates per day, making it suitable for real-time deployment in wearable systems. Conclusion: EpiSMART enables robust and personalized seizure detection under realistic and resource-constrained conditions by effectively integrating new data into existing models without degrading past knowledge. Significanc: This framework advances automated seizure detection by providing a continual learning approach that supports patient-specific adaptation and practical deployment in wearable healthcare systems. \DeclareSourcemap \maps [datatype=bibtex] \map \step [fieldset=ISSN, null] \step [fieldset=ISBN, null] \step [fieldset=urldate, null] \step [fieldset=note, null] \step [fieldset=eventtitle, null] \step [fieldset=pages, null] \step [fieldset=doi, null] \step [fieldset=language, null] I Introduction Epilepsy is a neurological disease that affects millions of people worldwide [ 1 ] , and it manifests itself primarily through the occurrence of seizures. Seizures are characterized by sudden and unexpected discharges of large groups of neurons, and their detection is crucial for prompt intervention and treatment [ 2 ] . The detection of epileptic seizures commonly relies on the analysis of electroencephalography (EEG) signals that capture the electrical activity of the brain. However, manual analysis of long-term EEG signals can be time-consuming and requires expert knowledge. Therefore, there has been growing interest in the development of automated methods for the detection of epileptic seizures. In particular, deep learning and machine learning techniques, such as convolutional neural networks (CNN), have shown promising results in seizure detection [ 3 , 4 , 5 ] . Unlike traditional machine learning, deep learning models can automatically learn relevant features from raw EEG data, eliminating the need for application-specific feature extraction [ 6 ] . This ability to learn from raw data makes deep learning particularly suitable for seizure detection, where robust features may not be easily identifiable [ 7 , 8 ] . Deep learning approaches are also well suited to develop personalized models due to their inherent adaptability [ 9 ] . Personalized models adapt to the unique EEG characteristics of each patient [ 10 ] . Considering them can improve performance in the detection of seizures, but training personalized models requires a substantial amount of data [ 11 ] . These have historically proven costly to collect in a hospital environment. However, the advent of wearable devices now allows long-term data collection [ 12 ] and the possibility of fine-tuning existing models rather than training them from scratch. Such continuous, real-world monitoring on wearable devices enables timely seizure detection, even outside of hospital, which can support rapid intervention, improve patient safety, and enhance quality of life. Personalization introduces its own challenges, particularly due to the non-stationary nature of data collected over time [ 13 ] . This is especially relevant in healthcare, where physiological parameters can fluctuate, leading to changes such as electrode impedance, variations in environmental noise, and alterations in exercise routines of patients [ 10 ] . Deep learning models, even after personalized fine-tuning, are inherently static and, hence, ill-equipped for dynamic environments where data distributions change over time. Continual learning strategies address this challenge by proposing approaches that enable deep learning models to continuously adapt to new information and environments while avoiding the need to retrain from scratch [ 14 ] . The application of continual learning to seizure detection presents specific challenges that require tailored solutions. Seizures are rare events that lead to a highly imbalanced dataset, which complicates the training process. Therefore, it is key to update models according to newly acquired data while at the same time retaining information on past events of high significance (such as seizures), thus avoiding catastrophic forgetting, which is a phenomenon where learning new information causes the model to forget previously acquired knowledge [ 14 ] . In addition, personalized healthcare solutions should achieve these goals with the limited resources of mobile devices. Recent efforts have explored the use of continual learning for seizure detection [ 15 , 16 ] , focusing mainly on adapting models as new data emerge, typically from unseen patients. Although promising, these approaches overlook two critical aspects: the need for personalization and the resource constraints inherent in embedded or wearable systems. A recent study [ 17 ] attempts to bridge this gap by incorporating both personalization and resource awareness. However, it assumes full access to the labeled data for each patient and performs model updates on an hourly basis. Such requirements introduce substantial annotation and computational overhead, making the approach impractical for real-world continuous use. This work addresses these limitations by introducing a continual learning framework for seizure detection at the edge that requires minimal annotation effort, limited memory capacity, and low computational overhead for personalization. Our method incrementally adapts to the evolving EEG patterns of individual patients while preserving crucial information from past seizure episodes. We show that models trained in a Leave-One-Out (LOO) setting fail to generalize effectively to unseen patients, highlighting the necessity of personalization. To overcome this, our approach uses a lightweight replay buffer [ 18 ] that selectively stores and reuses informative samples from the past. This allows the model to maintain performance over time without incurring prohibitive costs in memory, computation, or labeling. The main contributions of this paper are as follows: 1. We present EpiSMART (Epileptic Seizure Monitoring with Annotation-Reduced Training), a continual learning framework for personalized seizure detection that incrementally adapts to new patient data while preserving past knowledge. 2. To the best of our knowledge, EpiSMART is the first work which aims at minimizing the amount of required labeled data to enable scalable and memory-efficient continual learning. This design allows the system to operate under labeling, memory, and computation constraints, making it practical for long-term deployment. 3. We demonstrate that our method is both label and compute efficient. On average, it requires only 6.46 minutes of labeled data and 6.28 updates per day to adaptively update the model, significantly reducing the effort of expert annotation and computational overhead. 4. We validate our framework in the CHB-MIT dataset, demonstrating performance comparable to fully labeled continual updates, along with a 21.33% improvement in F1 score and a 77%