Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments 2025 Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments – References

Christian J. Kirkham, Dominic J. Anstey, Eloy de Lera Acedo · 2025

Read Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments 2025 Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments – References by Christian J. Kirkham, Dominic J. Anstey, Eloy de Lera Acedo (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-13010.txt.

Introduction

Christian Kirkham, Dominic Anstey and Eloy de Lera Acedo fit drift over time in 2025 for sky radio hunts of the first stars. The faint global signal needs a rock-steady gauge. Past gauges skip time data and assume match traits of sources.

Their noise-wave gauge fits a surface over time and pitch at once. Fits fill gaps to each antenna read time. On fake REACH data with a drifting amp, drift is cut out. New terms drop source match guesses and cut clashes in fits. Fakes then match truth to a hair, with spectrum error cut by near all.

Catalog record

CREATORChristian J. Kirkham, Dominic J. Anstey, Eloy de Lera Acedo
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE36 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2509-13010

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments 2025 Capturing System Drift with Time Series Calibration for Global 21-cm Cosmology Experiments – References Christian J. Kirkham, Dominic J. Anstey, Eloy de Lera Acedo Abstract To achieve the sensitivity required to detect signals from neutral hydrogen from the Cosmic Dawn and Epoch of Reionisation it is critical to have a well-calibrated instrument which has a stable calibration over the course of the observation. Previous Bayesian calibration methods do not explicitly use the time information available and make assumptions on the impedance matching of the reference sources. Here we present a new calibration method based on noise wave parameters which fits a calibration solution over time and frequency to the data, interpolating the solutions to the times at which the antenna is being measured. To test this method we simulate a dataset using measurements of the REACH receiver, modelling a low noise amplifier which is drifting over time. Fitting a polynomial surface in frequency and time to the simulated data demonstrates that we can remove the drift in the calibrated solution over time but leaves a chromatic residual. We further show that we can remove assumptions on the reflection coefficients of the reference noise source and the cold load, reducing degeneracies in the parameter fits. Applying this new calibration equation and surface fitting method to the simulated data removes the chromatic residual in the calibrated spectrum and recovers the parameters to within 0.06% of the truth and a 97% reduction in the RMSE of the spectrum of the validation source compared with previous calibration methods. For two parameters we report up to six times smaller fit error after the degeneracies are removed from the time-based calibration. 1 Introduction 21-cm radio cosmology experiments aim to infer the properties of the first stars and galaxies from radio emissions from neutral hydrogen (HI) in the Cosmic Dark Ages, Cosmic Dawn, and the Epoch of Reionization ( Furlanetto et al. 2006 ; Monsalve et al. 2018 ; Monsalve et al. 2019 ; Bevins et al. 2022 ) . They do so by measuring the redshifted hyperfine transition line which is at a rest wavelength of \lambda\approx 21\, cm or a frequency of \nu\approx 1420\, MHz as a statistical ‘spin temperature’, measured relative to the temperature of cosmic microwave background. Global 21-cm radio experiments use low-frequency radio antennae to detect this radio emission from the neutral hydrogen. Examples of such experiments are the Experiment to Detect the Global EoR Signature (EDGES) ( Bowman et al. 2008 ) , Shaped Antenna measurement of the background Radio Spectrum (SARAS) ( Singh et al. 2018 ; Singh et al. 2022 ) , Large Aperture Experiment to Detect the Dark Ages (LEDA) ( Price et al. 2018 ) , Probing Radio Intensity at high-Z from Marion (PRI Z M) ( Philip et al. 2019 ) , Mapper of the IGM Spin Temperature (MIST) ( Monsalve et al. 2023 ) and Radio Experiment for the Analysis of Cosmic Hydrogen (REACH) ( de Lera Acedo et al. 2022 ) . The first experiment to make a claimed detection of the 21-cm signal was the EDGES experiment ( Bowman et al. 2018 ) who found a flattened Gaussian absorption profile of depth 500^{+500}_{-200}\, mK centred at 78\pm 1\, MHz. The unusual depth and shape of this signal however requires exotic physics to explain it ( Barkana 2018 ; Feng & Holder 2018 ) . Recent observations by the SARAS experiment have placed constraints on this signal, ruling out the EDGES detection with 95.3% confidence ( Singh et al. 2022 ) . Concerns have been raised that there is an unmodelled systematic in the EDGES data ( Hills et al. 2018 ; Sims & Pober 2020 ) which is causing a biased fit. Hills et al. 2018 found that comparing the EDGES foreground fit to a physical model resulted in unphysical parameters, noting that the fit improves with the inclusion of a 12.5\, MHz sinusoid. The presence of this sinusoid is supported by the work of Sims & Pober 2020 , who note that this could be the result of a calibration error. As the global 21-cm signal absorption depth is predicted to be small – with an amplitude \lesssim 200\, mK ( Dhandha et al. 2025 ) – while the free-free and synchrotron emission from the galactic foregrounds will be of order 10^{3}-10^{4}\, K ( Shaver et al. 1999 ) , we require highly sensitive experiments to separate the signal from the foregrounds. To do so requires long integration times, with a REACH-like experiment requiring approximately 6.5 hours of integration at minimum to reduce the radiometer noise down to the level at which it can detect the EDGES signal ( de Lera Acedo et al. 2022 ) . As a result of this long integration time, we need to maintain a stable calibration over the observation to achieve the sensitivity necessary to detect the 21-cm signal. Previous calibration methods ( Rogers & Bowman 2012 ; Roque et al. 2021 ) have not considered calibration over time and so require the instrument to be kept stable over the course of the observation. This work will present a new method of calibration for global 21-cm cosmology experiments which fits a frequency-time surface to the calibration parameters, interpolating to the antenna observations between calibrator observations. This work will focus on calibrating the REACH experiment ( de Lera Acedo et al. 2022 ) , introducing the calibration of the receiver system in section 2.1 . In section 2.2 we will introduce a new way of calibrating a receiver to remove parameter degeneracies and in section 2.4 we present the surface fitting method. Section 2.5 outlines the generation of simulated data to test the method and in section 3 we present the results. Finally in section 4 we present the conclusions. 2 Methods 2.1 REACH Receiver Calibration Following Rogers & Bowman 2012 and Monsalve et al. 2017 , calibration of the REACH receiver is done using a combination of Dicke switching ( Dicke 1946 ) and noise wave parameters (NWP) introduced by Meys 1978 . In REACH the Dicke switching is done by switching between a reference source (or the antenna), a noise source with noise temperature T_{\mathrm{NS}}\approx 1400\, K, and a cold load at ambient temperature T_{\mathrm{L}} which are theoretically matched to the low noise amplifier (LNA). Using this noise wave parametrisation we can write the calibrated temperature in terms of the measured power spectral densities (PSD), P , and the reflection coefficients, \Gamma , ( Roque et al. 2021 ) \displaystyle\begin{split}T^{\prime}_{\mathrm{NS}}\left(\frac{P_{\mathrm{s}}-P_{\mathrm{L}}}{P_{\mathrm{NS}}-P_{\mathrm{L}}}\right)+T^{\prime}_{\mathrm{L}}=&T_{\mathrm{s}}\left[\frac{1-|\Gamma_{\mathrm{s}}|^{2}}{|1-\Gamma_{\mathrm{s}}\Gamma_{\mathrm{r}}|^{2}}\right]\\ &+T_{\mathrm{unc}}\left[\frac{|\Gamma_{\mathrm{s}}|^{2}}{|1-\Gamma_{\mathrm{s}}\Gamma_{\mathrm{r}}|^{2}}\right]\\ &+T_{\mathrm{cos}}\left[\frac{\mathrm{Re}\left(\frac{\Gamma_{\mathrm{s}}}{1-\Gamma_{\mathrm{s}}\Gamma_{\mathrm{r}}}\right)}{\sqrt{1-|\Gamma_{\mathrm{r}}|^{2}}}\right]\\ &+T_{\mathrm{sin}}\left[\frac{\mathrm{Im}\left(\frac{\Gamma_{\mathrm{s}}}{1-\Gamma_{\mathrm{s}}\Gamma_{\mathrm{r}}}\right)}{\sqrt{1-|\Gamma_{\mathrm{r}}|^{2}}}\right],\end{split} (1) where T_{\mathrm{unc}} , T_{\mathrm{cos}} , T_{\mathrm{sin}} are the frequency-dependent ‘noise wave parameters’ which are unknowns and are fitted for. Here P_{\mathrm{s}} and \Gamma_{\mathrm{s}} are the source received power and reflection coefficient respectively, \Gamma_{\mathrm{r}} is the LNA reflection coefficient, P_{\mathrm{NS}} is the power received from the noise source and P_{\mathrm{L}} is the cold load power. We measure the power with a spectrometer and the reflection coefficients with a vector network analyser (VNA), both of which are in the REACH receiver allowing full in-situ measurements of the system. Here we also fit for an effective noise source temperature, T^{\prime}_{\mathrm{NS}} ,

Read the complete text