Liquid Helium Cryogenic TEM below 1 Å
Suk Hyun Sung, Maya Gates, Nishkarsh Agarwal, Yang Zhang, William Millsaps, Miti Shah, Emily Rennich, Cong Li, Pu Yu, Miaofang Chi, Benjamin H. Savitzky, Ismail El Baggari, Robert Hovden · 2025
Read Liquid Helium Cryogenic TEM below 1 Å by Suk Hyun Sung, Maya Gates, Nishkarsh Agarwal, Yang Zhang, William Millsaps, Miti Shah, Emily Rennich, Cong Li, Pu Yu, Miaofang Chi, Benjamin H. Savitzky, Ismail El Baggari, Robert Hovden (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-12475.txt.
Introduction
Suk Hyun Sung and 12 co-authors demonstrate atomic imaging at very low temperature in a 2025 paper on cryogenic electron microscopy. Cooling samples below ninety kelvin can protect organic specimens from beam damage and reveal emergent electronic phases in quantum materials. Current side-entry liquid helium stages, however, lack the stability needed for the sharpest imaging.
The team reached sub-Angstrom imaging, resolution finer than the spacing of atoms, with a side-entry stage at specimen temperatures down to about twenty kelvin. They report low stage drift and stable hold times over extended periods. That combination addresses the mechanical and thermal stability problem that limited earlier designs. The result points toward next-generation cryogenic transmission electron microscopes for sensitive materials and biology.
Catalog record
| CREATOR | Suk Hyun Sung, Maya Gates, Nishkarsh Agarwal, Yang Zhang, William Millsaps, Miti Shah, Emily Rennich, Cong Li, Pu Yu, Miaofang Chi, Benjamin H. Savitzky, Ismail El Baggari, Robert Hovden |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 12 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2509-12475
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Liquid Helium Cryogenic TEM below 1 Å Suk Hyun Sung, Maya Gates, Nishkarsh Agarwal, Yang Zhang, William Millsaps, Miti Shah, Emily Rennich, Cong Li, Pu Yu, Miaofang Chi, Benjamin H. Savitzky, Ismail El Baggari, Robert Hovden Abstract Next-generation cryogenic transmission electron microscopes (TEM) aim to achieve high-resolution imaging at ultracold sample temperatures (< 90 K) and over extended hold times. Lower temperatures enable atomic-scale characterization with improved beam and dose resilience for organic specimens and access to emergent electronic phases in quantum materials. Side-entry liquid helium cooling stages presently lack the mechanical and thermal stability required to support sub-Angstrom information transfer in modern TEM. Here we demonstrate sub-Angstrom atomic imaging TEM with a side-entry stage at specimen temperatures down to ∼ \sim 20 K and with low stage drift and stable hold times. 1]The Rowland Institute at Harvard, Harvard University, Cambridge, MA 02138, United States 2]Department of Materials Science and Engineering, University of Michigan, Ann Arbor, MI 48109, United States 3]Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, United States 4]h-Bar Instruments, Ann Arbor, MI 48103, United States 5]State Key Laboratory of Low Dimensional Quantum Physics and Department of Physics, Tsinghua University, Beijing, 100084, China 6]Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN, United States 7]Thomas Lord Department of Mechanical Engineering & Materials Science, Duke University, Durham, North Carolina 27708, United States 8]Department of Chemistry, Brown University, Providence RI, 02912, United States 9]Department of Physics, University of Michigan, Ann Arbor, MI, 48105, United States *]Contributed equally †]e-mail: [email protected], [email protected] \firstAuthorLastName Sung 1 Liquid nitrogen cryogenic transmission electron microscopy (cryo-TEM) has driven atomic‐scale breakthroughs in structural biology [ 1 , 2 ] and, more recently, in materials science [ 3 , 4 , 5 , 6 ] . With liquid nitrogen cooling, sample temperatures in TEM typically reach 90–100 K [ 7 , 8 ] . Next-generation cryo-TEM aims to reach lower temperatures using liquid helium cryogenics, to increase radiation protection [ 9 , 10 , 11 , 12 , 13 , 14 ] and characterize electronic phase transitions in quantum materials [ 15 , 16 , 17 ] . Long hold times, low drift, and atomic resolution at these ultracold temperatures are required to enable such experiments. However, existing cooling methods utilize small cryogenic dewars and are limited by rapid cryogen boil‐off, mechanical vibrations, and thermal drift, which prevent sustained sub‐Angstrom imaging [ 18 ] . Liquid helium is sixty times more volatile than liquid nitrogen [ 19 ] , exacerbating the mechanical and thermal instabilities pervasive in cryo-TEM. In structural biology, Henderson et al. advocate that “the use of a microscope capable of cooling the specimen to liquid helium temperature should give more information from each micrograph” [ 20 ] . Russo’s group recently solved the long-standing specimen movement problem in liquid helium cryo-TEM, using novel Au grids and illumination schemes [ 21 ] , heralding renewed interest in novel biological structure determination through ultracold electron microscopy. Early TEM helium stage designs integrated cryogenic modules within the electromagnetic lenses [ 22 , 15 , 23 , 24 , 25 ] . While offering low base temperatures, this architecture is incompatible with modern aberration-corrected electron microscopes that prioritize side-entry holders and narrow electromagnetic pole pieces for high resolution. For side-entry sample loading, vibrations are ruinous for resolution—structure blurs in real space and high-frequency structural peaks disappear in reciprocal space. In 2007, Klie and colleagues captured atomic resolution images using a side-entry stage during fleeting moments of stability [ 26 ] . Zhu’s group has shown that stable imaging is generally only possible after the cryogen has fully evaporated—typically within 20 minutes—since the mechanical vibrations induced during active cooling are too severe [ 27 , 18 ] . However, once the cryogen is depleted, the sample temperature quickly rises and drift becomes severe [ 18 ] . A recent alternative design using continuous liquid helium flow achieves hold times exceeding 8 hours with high temperature stability, enabling TEM information transfer of 2.3 Å [ 28 ] . In that initial implementation, information transfer below 1 Å at ultracold cryogenic temperatures had not yet been demonstrated. Figure 1: Sub-Angstrom information transfer with ultracold cryogenic TEM imaging. Atomic resolution BF-TEM images of SrTiO 3 taken at 40 K. Inset) Fourier transform of the image shows [510] Bragg peak corresponding to information transfer up to 0.77 Å. Here we report atomic resolution imaging with sub-Angstrom information transfer, using a liquid‐helium TEM sample holder for modern aberration‐corrected transmission electron microscopes. The holder uses a continuous flow of liquid helium through a heat exchanger that thermally connects to the sample [ 28 ] . TEM imaging with sub‐Angstrom information transfer is achieved by leveraging passive vibration isolation of the sample. Through precise temperature regulation the stage achieves low drift—roughly twice lower than commonly used liquid nitrogen stages [ 29 ] . Further, these stable imaging and cryogenic cooling conditions are maintained over extended periods (more than 24 hours), enabling extended data collection. The same stability is also achieved at intermediate temperatures, enabling imaging of structural changes across variable temperatures. This ultracold specimen holder enables uninterrupted atomic‐resolution imaging with wide applicability to beam‐sensitive matter and electronic materials. Figure 1 a shows the atomic structure of a SrTiO 3 membrane taken at 40 K using the ultracold TEM specimen holder. The holder was inserted into a Thermo Fisher Scientific Spectra 300 operating at 300 kV. Bright-field TEM (BF-TEM) images were acquired at 30 ms per frame and aligned using image registration [ 30 ] . The Fourier transform shows information transfer down to 0.77 Å. The sample temperature was tuned to 40 K where a quantum paraelectric phase emerges in SrTiO 3 [ 31 ] . Figure 2 a shows a BF-TEM image of the atomic structure of two-dimensional 2H-NbSe 2 at 23 K, closer to the sample holder’s base temperature. Atomic-scale stability is enabled by two stage vibration isolation separating the specimen from the liquid helium flow in the holder backend (Fig. 2 b). The vibration isolator includes flexible high-vacuum bellows and compressed viscoelastic material for damping. Figure 2 c shows velocity spectra acquired using geophone vibration sensors placed before and after the isolation assembly; vibrations are damped by \sim 12 times, thus enabling TEM imaging at atomic resolution. Beyond vibration, sample drift due to unregulated temperature changes is a persistent limitation in cryo-TEM, causing resolution loss, image distortion, or the sample to shift from the field of view. Figure 2 d shows low sample drift, approximately 0.37 Å/s. Stage drift at cryogenic temperature is due to unregulated temperature changes, from cryogenic boil-off or additional heat loads, leading to thermal expansion and contraction of the sample holder [ 29 , 30 ] . As a point of comparison, high-resolution imaging in conventional side-entry liquid nitrogen cryo-TEM is performed under drift rates \sim 0.6–1 Å/s range [ 5 , 29 ] . For the best imaging resolution and signal-to-noise ratio, cryo-TEM typically leverages fast multi-frame acquisition and image alignment to overcome sample drift and noise in single frames [ 32 , 30 ] . The atomic-scale stability and cryogenic cooling conditions are sustained for extended periods (over 24 hours), as long