An on-sky investigation into factors limiting the performance of Keck-NIRC2 for conducting infrared high-contrast imaging

Rachel Bowens-Rubin, Maissa Salama, Jayke S. Nguyen, William Thompson, Philip Hinz · 2025

Read An on-sky investigation into factors limiting the performance of Keck-NIRC2 for conducting infrared high-contrast imaging by Rachel Bowens-Rubin, Maissa Salama, Jayke S. Nguyen, William Thompson, Philip Hinz (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-07138.txt.

Introduction

On-sky tests of the Keck telescope's NIRC2 camera are reported by Rachel Bowens-Rubin and 4 co-authors in 2025. NIRC2 is a near-infrared imager used to photograph planets and brown dwarfs next to bright stars, a task called high-contrast imaging. Three effects that may limit its performance at wavelengths of 3 to 5 micrometers are put under the microscope.

First, the team measures how much light a vortex coronagraph, a device that blocks starlight, lets through in two filters. Second, using a recent electronics upgrade, they find the sky background changes in under 30 seconds, which could improve background removal. Third, they track how the image derotator makes the background uneven across the frame. Practical advice for future surveys ends the report, so observers can plan around each effect.

Catalog record

CREATORRachel Bowens-Rubin, Maissa Salama, Jayke S. Nguyen, William Thompson, Philip Hinz
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE32 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2509-07138

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

An on-sky investigation into factors limiting the performance of Keck-NIRC2 for conducting infrared high-contrast imaging Rachel Bowens-Rubin, Maissa Salama, Jayke S. Nguyen, William Thompson, Philip Hinz Abstract The most common instrument used by the exoplanet/brown dwarf direct imaging community at the W.M. Keck Observatory is currently the NIRC2 near-infrared imager. We performed on-sky testing to investigate three effects which may be limiting the performance of NIRC2 when conducting high-contrast imaging observations from 3 − 5 ​ μ 3-5\mu m First, we report the measurements of an on-sky test of the throughput of the L/M vector vortex coronagraph. We quantify the throughput and additional background flux penalties, noting that the performance effects of using the vector vortex coronagraph in the Ms-filter are greater than in the Lp-filter. Second, we utilize the recently commissioned NIRC2 electronics upgrade to measure the sky variability at sub-second speeds. We find that the background varies at timescales of less than 30 s, indicating that the electronics upgrade may open an opportunity to improve the sky-background subtraction of future surveys. Third, we document the contribution of the image derotator to the spatial non-uniformity in the background flux. We conclude by giving a set of recommendations of how the Keck-NIRC2 high-contrast imaging community can adapt their observing strategies to improve the sensitivity of future surveys. a]University of California Santa Cruz, 1156 High St, Santa Cruz CA, USA b]University of California San Diego, Astronomy & Astrophysics Department, 9500 Gilman Dr., San Diego CA 92092, USA c]University of Victoria d]University of California Observatories, 1156 High St, Santa Cruz CA, USA keywords Coronagraphy, Infrared imaging, Exoplanets † † authorinfo: Further author information: (Send correspondence to R. Bowens-Rubin) R.B.R.: E-mail: [email protected] 1 INTRODUCTION The NIRC2 near-infrared imager 1 1 1 NIRC2 documentation: https://www2.keck.hawaii.edu/inst/nirc2/ is currently the workhorse instrument for the exoplanet/brown dwarf direct imaging community at the W.M. Keck Observatory. NIRC2 is a 1Kx1K Aladdin-3 detector that can operate from 1-5 \mu m. It is positioned behind the adaptive optics bench on Keck-II telescope. Direct imaging observations of exoplanets and brown dwarfs are commonly completed with NIRC2 using Lp filter (3.776 \pm 0.700 \mu m) [ 1 , 2 , 3 ] or the Ms filter (4.670 \pm 0.241 \mu m) [ 4 , 5 , 6 , 7 , 8 ] . These are the two reddest filters available using NIRC2. 2 2 2 NIRC2 filter list: ( https://www2.keck.hawaii.edu/inst/nirc2/filters.html Using the 3-5\mu m wavelength range allows for the greatest discovery spaced of cold companions ( <500 K). These wavelengths are also used to distinguish between atmospheric models to measure the disequilibrium carbon chemistry and metallicity [ 9 ] . In 2023, the readout electronics were upgraded on NIRC2 to decrease the full frame transfer time to save a fits file from 12s to 0.5s, increasing the observing efficiency from 30% to 75%. [ 10 ] This upgrade also enabled a high-speed subframing readout. For each science frame, the individual coadds are packaged into a .unp file can be viewed as an image cube. Typical integration times for coadd frame are between 0.1 - 0.5s with a total image integration time of 30s. The upgrade makes these sub-second timescales available when previously the sampling would only occur on timescales of >30s . NIRC2 was historically operated with a frame size of of 512 \times 512 pixels (5.090 arcsec \times 5.090 arcsec; pixel scale = 0.009942 \pm 0.00005 arcsec/pixel, Keck General Specs ). However, since the electronics upgrade, observers can now experience little penalty for using the full frame size (1024 x 1024 pixels). If the central star is bright and high-contrast is required at small inner working angles ( <0.5 arcsec) to accomplish the science objective, observers often elect to use the vector vortex coronagraph (VVC) installed at Keck-II to suppress the central starlight [ 11 ] . The first VVC was installed on NIRC2 in March 2015 3 3 3 Vortex User Manual . Two VVCs have been offered to NIRC2 observers over the past decade, one optimized for K band ( vortexlk ) and another optimized for L/M-band ( vortexlm ). The centering of the vortex is controlled using the QACTIS software package [ 12 ] . Each QACITS sequence consists of a set of (1) calibration images to acquire an off-axis star PSF and sky images, (2) optimization images to center the star on the vortex and stabilize the tip/tilt in the adaptive optics system, (3) a series of science images. When the VVCs is used in the optical pathway, observers use the “fixedhex” pupil stop which was designed specifically for use with the VVC. To enable angular differential imaging (ADI) post-processing analysis methods with the VVC, NIRC2 observers typically operate Keck in vertical angle mode (with PA =4.43^{\circ} ). In this proceeding, we investigate three effects which have been suspected to be limiting the performance of high-contrast imaging with NIRC2 in Lp and Ms filters using on-sky testing: • Section 2 is concerned with the sensitivity impacts introduced by the vector vortex coronagraph. We document the throughput loss and additional background flux suspected to be introduced by including the coronagraph in the optical path. This effect limits our ability to detect and study colder/smaller/older exoplanets and brown dwarfs at separations >0.5 arcsec orbiting bright host stars ( >5 mag). • The measurements presented in Section 3 are concerned with the speed of the temporal variability in a uniform background due to the changing sky background flux level. An improved sky background flux correction could expand the set of colder/smaller/older exoplanets and brown dwarfs that we can study using NIRC2 around both bright and dim stars. • Section 4 documents the added spatial variability caused by the Keck-II image derotator. Understanding and correcting this spatial variability would improve our ability to study cold extended sources such as protoplanetary disks. 1.1 Background sensitivity expected for NIRC2 with and without coronagraph The W.M. Keck Observatory provides an online tool to help observers plan their NIRC2 observations, the NIRC2 SNR and Efficiency Calculator . This tool provides a theoretically predicted estimate for the SNR of detecting an object of a user-defined magnitude and total exposure time. The efficiency measurement reported by this tool is no longer accurate as of the 2023 electronics upgrade, but it can still be utilized to assess the expected signal-to-noise ratio. The SNR estimate assumes an object is in a background-limited regime of the image and is not affected by another source in the field. Thus, the NIRC2 calculator is not a good predictor of a high-contrast imaging observation at inner working angles tight enough to be in the contrast-limited regime and cannot provide performance estimates when using the vector vortex coronagraph mask. Modified signal-to-noise equations that incorporate the use of the vortexlm are presented in the appendix of Bowens-Rubin et al 2023 [ 6 ] . Observers planning to use the Lp filter in conjunction with the vortexlm can utalize the Vortex Imaging Contrast Oracle (VICO) [ 13 ] to predict the expected contrast as a function of separation. VICO’s contrast predictions are based off a training set of 304 targets observed between 2015 to 2018. Because this tool is trained on real data, VICO produces more