CONCERTO: forward modeling of interferograms for calibration
A. Lundgren, A. Beelen, G. Lagache, F.-X. D e ´ \rm\acute{e} sert, A. Fasano, J. Macias-Perez, A. Monfardini, P. Ade, M. Aravena, E. Barria, A. Benoit, M. B e ´ \rm\acute{e} thermin, J. Bounmy, O. Bourrion, G. Bres, C. De Breuck, M. Calvo, A. Catalano, C. Dubois, C.A Dur a ´ \rm\acute{a} n, T. Fenou · 2025
Read CONCERTO: forward modeling of interferograms for calibration by A. Lundgren, A. Beelen, G. Lagache, F.-X. D e ´ \rm\acute{e} sert, A. Fasano, J. Macias-Perez, A. Monfardini, P. Ade, M. Aravena, E. Barria, A. Benoit, M. B e ´ \rm\acute{e} thermin, J. Bounmy, O. Bourrion, G. Bres, C. De Breuck, M. Calvo, A. Catalano, C. Dubois, C.A Dur a ´ \rm\acute{a} n, T. Fenou (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-04929.txt.
Introduction
Setting the scale of a telescope instrument that maps ionised carbon emission needs a model that can replay its own observations. A. Lundgren, lead author with thirty-eight co-authors, present a forward model for the CONCERTO instrument in a 2025 astronomy paper. CONCERTO, a Fourier-transform spectrometer on the APEX telescope in Chile, observed a field in COSMOS to study early cosmic line changes.
Their model simulates the spectral response and raw interferograms for each scan under known inputs. A pipeline built for the task describes raw data across varied sky conditions. With the model, the team measure how scans line up and how strongly each part responds. That supports setting the true brightness scale of the spectra.
Catalog record
| CREATOR | A. Lundgren, A. Beelen, G. Lagache, F.-X. D e ´ \rm\acute{e} sert, A. Fasano, J. Macias-Perez, A. Monfardini, P. Ade, M. Aravena, E. Barria, A. Benoit, M. B e ´ \rm\acute{e} thermin, J. Bounmy, O. Bourrion, G. Bres, C. De Breuck, M. Calvo, A. Catalano, C. Dubois, C.A Dur a ´ \rm\acute{a} n, T. Fenou |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 51 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2509-04929
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
CONCERTO: forward modeling of interferograms for calibration A. Lundgren, A. Beelen, G. Lagache, F.-X. D e ´ \rm\acute{e} sert, A. Fasano, J. Macias-Perez, A. Monfardini, P. Ade, M. Aravena, E. Barria, A. Benoit, M. B e ´ \rm\acute{e} thermin, J. Bounmy, O. Bourrion, G. Bres, C. De Breuck, M. Calvo, A. Catalano, C. Dubois, C.A Dur a ´ \rm\acute{a} n, T. Fenouillet, J. Garcia, G. Garde, J. Goupy, C. Hoarau, W. Hu, J.-C. Lambert, F. Levy-Bertrand, J. Marpaud, R. Parra, G. Pisano, N. Ponthieu, L. Prieur, D. Quinatoa, S. Roni, S. Roudier, D. Tourres, C. Tucker, M. Van Cuyck Abstract Context. The CarbON [CII] line in post-rEionisation and ReionisaTiOn epoch (CONCERTO) instrument is a low-resolution mapping Fourier-transform spectrometer, based on lumped-element kinetic inductance detector (LEKID) technology, operating at 130–310 GHz. It was installed on the 12-meter APEX telescope in Chile in April 2021 and operated until December 2022. CONCERTO’s main science goal is to constrain the [CII] line fluctuations at high redshift. To reach that goal CONCERTO observed 1.4 deg 2 in the COSMOS field. Aims. To ensure accurate calibration of the data, we have developed a forward model capable of simulating both the spectral response and the corresponding interferograms for each scan of observation in the COSMOS field. We present the modeling approach that enables us to reproduce the expected instrument outputs under controlled input conditions and provides a framework for the different calibration steps, including the absolute brightness calibration of the spectra. Methods. We constructed a dedicated analysis pipeline to characterize the raw interferometric data (interferograms) obtained under a broad range of atmospheric conditions at APEX. Using the forward model, we measured the interferogram alignment with the optical path difference (zero path difference, ZPD) and the relative response of each KID (flatfield). Together, these elements enable a robust characterization of the instrument’s spectral brightness calibration. Results. We demonstrate that the zero path difference systematically varies with elevation and across detectors, due to small optical misalignments and elevation-dependent mechanical deformations of the optics structure. The full measurement of these variations allow us to construct a data base that is used to accurately determine the zero path difference for each measured individual interferogram. The flatfield shows systematic variations with detector position but is extremely stable with time and atmospheric contribution. The accurate determination of the zero path differences and flatfields allows us to construct spectral cubes that combine all detectors and all blocks of data. Finally we present an novel method to calibrate the absolute brightness of those spectral cubes, which is immune to the exact knowledge of the bandpasses and directly applicable to extended emission. Conclusions. Our analysis establishes a framework for precise calibration directly from on-sky data. This approach ensures reliable performance for cosmological and astrophysical applications and can be readily adapted to future LEKID-based spectrometers. 1 Introduction Modern astrophysics increasingly relies on instruments of high complexity, designed to address demanding scientific objectives with unprecedented accuracy. Meeting these objectives requires not only advances in hardware but also a detailed understanding of instrumental behavior. Comprehensive modeling has thus become indispensable: it enables the prediction of performance, the identification and mitigation of systematic effects, and the validation of data analysis pipelines. In the (sub-)millimeter, Fourier spectroscopy (FTS) mapping meets the requirements for wide-area coverage and low-resolution spectroscopy in astronomical observations. By recording interferograms generated from the superposition of two optical beams and applying Fourier analysis, FTS delivers spectral information with broad frequency coverage, modest spectral resolution (with R \sim 100-500), and full FoV sampling in a single measurement. This combination has proven particularly valuable in studies of the Cosmic Microwave Background (CMB), as exemplified by the FIRAS instrument ( Mather et al. 1999 ) and other space-borne instruments such as SPIRE ( Griffin et al. 2010 ). It has also been adopted as a baseline for several proposed above-the-atmosphere experiments, including PIXIE ( Kogut et al. 2025 ) and BISOU ( Maffei et al. 2024 ). For ground-based observations, atmospheric fluctuations require the use of fast detectors, with kinetic inductance detectors (KIDs) representing a well suited technology available in large-format arrays at mm wavelengths ( Catalano et al. 2020 ). KIDs have already been deployed in photometric mm-instruments such as NIKA ( Monfardini et al. 2010 ) and NIKA2 ( Adam et al. 2018 ), which were both installed at the IRAM 30-m telescope at Pico Veleta (and in the case for NIKA2, still is). A particularly well-suited implementation of FTS in this context is the Martin–Puplett Interferometer (MPI, Martin & Puplett 1970 ), which has already been employed in experiments such as KISS ( Fasano et al. 2020 ) and OLIMPO ( Masi et al. 2008 ), and constitutes the core design of the CONCERTO spectrometer. The CONCERTO project ( Monfardini & Lagache 2021 , Concerto Collaboration et al. 2020 ) was conceived as a pathfinder to demonstrate wide-field spectroscopic mapping of the mm sky using an MPI-based FTS coupled to KID arrays. To maximize its scientific potential, CONCERTO is accompanied by a modular and parameterized instrument model that incorporates key instrumental and environmental effects, including detector noise, atmospheric fluctuations, and scan-induced systematics. As shown in Fasano et al. to be submitted , this framework successfully reproduces major aspects of CONCERTO’s performance when compared with observational data, and it provides a powerful tool for assessing systematics, optimizing observing strategies, and guiding the design of future mm-wave spectroscopic instruments, both ground- and space-based. The CONCERTO instrument was installed on the APEX telescope ( Güsten et al. 2006 ) in April 2021. Commissioning runs were conducted shortly thereafter, and regular science operations took place between July 2021 and December 2022. The main scientific program is a line-intensity mapping survey of the COSMOS field ( Scoville et al. 2007 ) , complemented by dedicated observations of the Sunyaev–Zeldovich effect in galaxy clusters, star-forming regions (including the Galactic Center) and evolved stars carried out during open time. For a comprehensive description of the observing campaign and operational procedures, we refer the reader to Hu et al. 2024 . The first scientific exploitation of CONCERTO data has recently been reported, with observations of the Orion Nebula revealing both CO(2–1) and water emission lines alongside the continuum. These results showcase the instrument’s spectral capabilities; see Désert et al. 2025 for a detailed discussion. The purpose of this paper is to introduce a forward model for CONCERTO interferograms, describing its components, architecture and implementation, and validation on real data. The model allows us to isolate, quantify, and correct for the impact of specific instrumental and environmental systematics, thereby supporting robust data interpretation. The paper is organized as follows. Section 2 presents briefly the CONCERTO instrument. Section 3 describes the observations we used in our analysis. In Sect. 4 , we provide a summary of the data reduction that is needed for our work. Section 5 develops the forward data model of CONCERTO raw interferograms, accounting for atmospheric emission, reference-source and stray-light contributions. In Section 6 , we report on the measurements of the zero path difference and the instrumental response from interferogram timelines for each detector. In sect. 7 , we focus on an original method to derive the absolute brightness calibration of spectra. Finally, Sect.