A Mathematical Model of Hybrid Microgrid With Pole Placement Controller Using State Feedback For Stability Improvement
Yangyadatta Tripathy, Barjeev Tyagi · 2025
Read A Mathematical Model of Hybrid Microgrid With Pole Placement Controller Using State Feedback For Stability Improvement by Yangyadatta Tripathy, Barjeev Tyagi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2509-01749.txt.
Introduction
Yangyadatta Tripathy and Barjeev Tyagi build a full math model of a hybrid microgrid, a small power network that mixes direct and alternating current parts. The model joins converters, which change power from one form to another, with their controls and loads. Inputs come from sources like solar cells, batteries, or fuel cells at a steady direct voltage. Filters smooth the output before it reaches the lines.
Each converter type is modeled with its own states and inputs, then three of each are combined. Network and load models complete the hybrid system. Tests of the model eigenvalues, which flag stable or unstable modes, guide a controller design. Placing those values by feedback steadies the grid.
Catalog record
| CREATOR | Yangyadatta Tripathy, Barjeev Tyagi |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 40 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2509-01749
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
A Mathematical Model of Hybrid Microgrid With Pole Placement Controller Using State Feedback For Stability Improvement Yangyadatta Tripathy, Barjeev Tyagi Abstract This paper presents the development of a mathematical model of a converter state space model for a hybrid microgrid. The hybrid model combines the models of components such as DC-Converters, DC-AC converters, and their individual controllers, as well as loads. The input to the converter is considered a constant DC voltage, assumed to originate from distributed generations like solar, battery storage, or fuel-cells. The converter output is connected to a DC line through an LCL filter. The controller circuitry is designed to regulate the voltage, current, and power from the converter. Sensors are strategically placed to measure the currents, voltages, and power, and calculate the reference pulse signal using PWM for the switch. Similarly, the DC-AC converter is modeled. In the state space domain the converter models is used to design overall microgrid system. A single DC converter has six states and two inputs, with all states as outputs. A single DC-AC converter has thirteen states and three inputs, with all states as outputs. Three such converters of each type are considered to develop the DC microgrid and AC microgrid, which are then combined using mathematical analysis to model a hybrid microgrid. For the hybrid microgrid development, network and load models were also included. Eigenvalue analysis has been conducted to study the small signal stability of the considered system. The complete state space model of the hybrid microgrid has been programmed, and a pole-placement controller has been designed to enhance the stability of the system. I Introduction The usage of renewable energy sources is being popular due to low carbon footprint and to minimize environmental polution [ 1 ] resulting to slowdown climate change. The integration of the energy sources like solar and wind energy etc. with the conventional energy sources is required. Microgrid infrastructure has been a promising solution to augment conventional plant stability and offering efficient energy distribution. Microgrids offer several advantages, such as higher efficiency [ 2 ] , natural integration of renewable-based generation and storage devices, and compatibility with consumer electronics. Renewable-based generations coupled with storage devices in microgrids [ 3 ] can be made dispatchable, which is an essential feature of this technology. With the rise of electronic components in domestic loads, the compatibility with consumer electronics is also another benefit [ 2 ] . As a result, microgrids have gained popularity and are often considered for various applications, including community-based systems in remote and developing regions. In microgrids, storage systems are employed as dispatchable units alongside renewable generations to enable voltage regulation and stability retention. However, the widespread adoption of storage systems is often hindered by their high capital cost, which remains a significant barrier. Nevertheless, the integration of storage systems with renewable-based generation in microgrids remains a crucial strategy for enhancing the efficiency, reliability, and flexibility of power distribution systems. Storage systems are used as dispatchable units alongside renewable generation for applications like voltage regulation and stability retention in microgrids. However, the primary barrier to the widespread use of storage for these applications is its high capital cost [ 4 ] . As microgrids become more widely deployed, controllers are essential for maintaining system stability. Integrating controllers ensures the system states remain within acceptable bounds, improving stability in complex dynamic situations. Several research papers have reported stability studies [ 5 ] , [ 6 ] on DC microgrid operations, discussing small-signal stability, also known as dynamic or steady-state stability. These studies observe the behavior of system states in response to small perturbations to validate small-signal stability. For broader analyses, such as transient or fault analysis, large-signal studies are conducted. Microgrids are susceptible to instability when subjected to constant power loads (CPL) due to the negative impedance characteristics of these loads. In [ 5 ] , the voltage stability issue is addressed by modeling the system’s stability as a parallel impedance curve. The presence of CPL introduces unstable poles, which degrade the system’s stability. To mitigate this instability, methods such as filtering, load shedding, or appropriate control strategies are required. The parallel operation of microgrids necessitates droop control, which can lead to low-frequency instabilities that demand prompt attention. In [ 6 ] , the correction of low-frequency oscillations in DCMGs is explored. Virtual impedance is employed in [ 7 ] to enhance stability for constant power loads. CPL is identified as the primary cause of dynamic interactions in DCMGs, with distributed generators, load dynamics, and various resonant phenomena influencing high-frequency voltage and current oscillations. A detailed analysis of high-frequency dominant modes and their damping is presented in [ 7 ] . Furthermore, an eigenvalue-based study on the small-signal model of a community DC microgrid that integrates distributed DC electric springs is conducted [8]. DC electric springs, which are demand-side management technologies, help reduce storage needs in a microgrid. This study evaluates the destabilizing effects of CPLs and performs a sensitivity analysis of frequency modes in response to control parameter variations. For large load variations or faults in a microgrid, large signal analysis becomes essential. This approach uses nonlinear mathematical methods to assess the system’s behavior under significant disturbances. Large signal analysis covers a broader domain than small signal analysis and depends on the system’s order. In [ 8 , 9 , 10 ] , large signal analysis is applied, and islanded DCMG modeling is performed. For various load types, including constant impedance, constant current, and constant power in parallel boost-converter-based DC microgrids, a current-limiting droop controller is designed in [ 11 ] . This controller ensures closed-loop stability and power sharing. However, the main limitation of current-limiting controllers is their ineffectiveness during transient conditions, as they are saturation-based. This leads to issues like integrator windup, where the integral control action exceeds the saturation limits of the control element, preventing reliable closed-loop stability. In research papers, the small-signal analysis of microgrids, around the operating points, the low-frequency oscillations are present. To address these issues of low-frequency instabilities, a robust state feedback controller is required to integrate in the proposed model [ 12 ] . The state feedback controller plays an important role for placing the poles of unstable system in desired locations within 10% accuracy which makes the system Lyapunov stable. The proposed model ensures closed-loop stability during load-transients. The aim and contribution of the paper are as follows. 1. A DC microgrid state space model is developed considering the dynamics of DC-DC converter and filter and connector as power circuit and current and voltage controllers. 2. An AC microgrid model is developed considering the dynamics of ac converters and filters as well as bus-connecting lines and loads. An interlinking converter was modeled implementing swing equation and power controller for bidirectional power flow between ac and dc microgrids. 3. A State feedback pole-placement controller was implemented to make unstable poles of the modelled system stay in the desired locations for stability. Stability region with respect to droop control gains were established. I-A Organisation of the paper This paper is organized as follows. In section II, the small signal model for a complete DC Microgrid components i.e. DC-DC converter is developed, representing the dynamics of