Read Nonlinear refrigerator with a finite-sized cold heat bath by I. Iyyappan, Yuki Izumida, Sibasish Ghosh (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-21333.txt.

Introduction

Iyyappan, Yuki Izumida, and Sibasish Ghosh study a refrigerator that cools a finite reservoir in a 2025 paper. Everyday fridges draw from an endless cold side in theory, but real cold baths are small and warm up tasks change them. Efficiency limits shift once the cold bath itself changes temperature during cooling.

Their setup links a finite cold bath to an endless hot one under nonlinear response. Work input pushes heat uphill while the cold bath falls toward a target temperature. Minimizing the work yields the best path for that temperature drop. The performance coefficient is expressed against average input power. Bounds come from extreme dissipation cases. Results depend strongly on how the finite bath stores heat.

Catalog record

CREATORI. Iyyappan, Yuki Izumida, Sibasish Ghosh
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE21 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2508-21333

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Nonlinear refrigerator with a finite-sized cold heat bath I. Iyyappan, Yuki Izumida, Sibasish Ghosh Abstract We study the refrigerator working between a finite-sized cold heat bath and an infinite-sized hot heat bath (environment) in the nonlinear response regime. We assume that the initial temperature T i T_{i} of the finite-sized cold heat bath satisfies T i ≤ T h T_{i}\leq T_{h} , where T h T_{h} is the temperature of the hot heat bath. By consuming the input power, the refrigerator transfers the heat from a finite-sized cold heat bath to the hot heat bath. Hence, the temperature of the finite-sized cold heat bath decreases until it reaches the desired low-temperature T f T_{f} . By minimizing the input work for the heat transport process, we derive the optimal path for temperature change. We calculate the coefficient of performance as a function of average input power. We also obtain the bounds for the coefficient of performance by applying the asymmetric dissipation limits. I Introduction Optimizing the performance of heat engines and refrigerators is a problem that has been studied for centuries. Efficiently utilizing limited energy resources is vital to fulfilling the power demands of our present world. The first optimization of energy conversion from heat to work goes back to 1824 by Sadi Carnot carn . He showed that the efficiency of a heat engine attains its maximum when it works reversibly, and it is given by the Carnot value \eta_{\rm C}=1-T_{c}/T_{h} . Here, T_{c} and T_{h} are the temperatures of the cold and hot heat baths, respectively. The inverse operation of a heat engine is called the refrigerator which transports heat from the cold heat bath to the hot heat bath by consuming the input work. The maximum coefficient of performance (COP) of the refrigerator is given by \varepsilon_{\rm C}=T_{c}/(T_{h}-T_{c}) cal . Carnot devices are impractical. In the case of heat engines, it delivers zero power output, and for refrigerators, it provides zero cooling power. Exactly, half a century ago in 1975, Curzon and Ahlborn constructed a finite-time Carnot heat engine (endorevesible heat engine) and showed the efficiency at maximum power as \eta_{\rm CA}=1-\sqrt{T_{c}/T_{h}} cur22 . This simple and elegant result opens up a new field of study called finite-time thermodynamics and208 ; and157 ; rub127 ; sal211 ; dev570 ; sal354 . Later, the COP of endorevesible Carnot refrigerators at maximum cooling power was studied by Agrawal and Menon agr531 . In 2005, Van den Broeck investigated the generic heat engine using linear irreversible thermodynamics (LIT) without invoking any specific heat transfer law to calculate the heat injection and rejection van190 . Subsequently, de Cisneros et al. studied the performance of linear irreversible refrigerators jim057 . For refrigerators, the LIT framework can be described as follows. When the temperature difference between the hot and cold heat baths, \Delta T=T_{h}-T_{c} is very small compared to the reference values (i.e., T_{h}\approx T_{c} ), and the external mechanical force F applied to the refrigerator is also very small, then, the Onsager relations can be written as jim057 ; ons226 J_{1}=L_{11}X_{1}+L_{12}X_{2}, (1) J_{2}=L_{21}X_{1}+L_{22}X_{2}. (2) Here, L_{ij} ( i,j=1,2 ) is the Onsager coefficient. We defined the mechanical thermodynamic force X_{1}=F/T_{h} , and the corresponding flux (e.g., velocity of the piston), J_{1}=\dot{x} . We also defined the thermal thermodynamic force X_{2}=1/T_{h}-1/T_{c} , and the corresponding heat flux J_{2}=\dot{Q_{c}} , which is absorbed from the cold heat bath at temperature T_{c} . The input power is given by P=F\dot{x}=T_{h}J_{1}X_{1}. (3) The second law of thermodynamics imposes a constraint on the Onsager coefficients, L_{11}\geq 0,\;L_{22}\geq 0,\;L_{11}L_{22}-L_{12}L_{21}\geq 0. (4) In our study, we assume the reciprocity relation, L_{12}=L_{21} cal . In real heat devices, they operate at a finite rate, and hence heat dissipation is unavoidable. To include the heat dissipation beyond the framework of LIT, Izumida, and Okuda added the nonlinear term to the heat flux, J_{2} izu100 . It is named a minimally nonlinear irreversible model. One can show that the minimally nonlinear irreversible model includes the low-dissipation model as a special case izu100 ; esp150 . The minimally nonlinear irreversible heat devices were widely studied in the literature izu1000 ; she012 ; lon062 ; she022 ; lon052 ; izu052 ; lon0521 ; iyy012 ; liu717 . In addition to the finite-time constraint, practical heat devices have finite-sized energy source or sink, which have significant consequences on their operation and performance ond681 ; ond472 ; and270 ; and266 ; lef701 ; yan811 . Izumida and Okuda investigated the heat engine working between the finite-sized hot heat source and an infinite-sized cold heat bath using the linear irreversible thermodynamics izu180 . Inspired by their study, several authors focused on finding the finite-sized bath effects on the efficiency of heat engines wan062 ; wan012 ; joh100 ; joh012 ; iyy500 ; ma100 ; yua022 ; hua125 . Refrigerators were used in several places. For example, food storage at home, industrial manufacturing, research labs, space stations, medical fields, etc. Whenever we want to cool the system, it always has a finite size. For example, consider air inside the fridge or the living room, which acts as a cold bath. It contains only a finite number of molecules and hence its heat capacity becomes finite. The absorbed heat from the cold bath is rejected to the environment, which is extremely large compared to the cold bath size. Therefore, we consider the environment as a hot heat bath with infinite heat capacity. Despite its practical significance, we found little study on refrigerators working with a finite-sized cold heat bath and an infinite-sized hot heat bath except for ron040 . Therefore, in this work, we investigate the nonlinear irreversible refrigerator which includes the dissipation effect working with a finite-sized cold heat bath and an infinite-sized hot heat bath. We assume that initially the temperature of the finite-sized cold heat bath satisfies T_{i}\leq T_{h} , which we may encounter in our everyday life. A refrigerator starts transporting heat from the finite-sized cold heat bath to a hot heat bath by consuming the input work/power. We assume that the lowest temperature the finite-sized cold heat bath can reach is T_{f}<T_{i} . We optimize the input work required to reach the desired low-temperature T_{f} , and study the performance of the refrigerator. This paper is organized as follows. In Sec. II, we briefly describe the nonlinear irreversible refrigerator model, and in Sec. III, we apply the finite-sized cold heat bath effect to this model. In Sec. IV, we discuss the optimization method, and in Sec. V, we present our results. Finally, we conclude in Sec. VI. Figure 1: The schematic diagram of a minimally nonlinear irreversible refrigerator working with a finite-sized cold heat bath and an infinite-sized hot heat bath. II Non-linear Refrigerator The schematic diagram of a minimally nonlinear irreversible refrigerator is given in Fig. 1 , where we denote the temperature of the finite-sized cold heat bath by T instead of T_{c} , and C_{V} is the heat capacity at constant volume. In our work, we assume that the volume of the cold heat bath does not change during the heat transfer process. Izumida and Okuda explicitly added a second-order term in the heat flux in Eq. ( 2 ). Therefore,

Read the complete text