CUTE-MRI: Conformalized Uncertainty-based framework for Time-adaptivE MRI Journal: Medical Image Analysis
Paul Fischer, Jan Nikolas Morshuis, Thomas Küstner, Christian Baumgartner · 2025
Read CUTE-MRI: Conformalized Uncertainty-based framework for Time-adaptivE MRI Journal: Medical Image Analysis by Paul Fischer, Jan Nikolas Morshuis, Thomas Küstner, Christian Baumgartner (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-14952.txt.
Introduction
Fischer and colleagues present in 2025 CUTE-MRI, a framework that lets an MRI scan stop itself once the result is precise enough. Faster scans usually fix the speed-up in advance, risking images too weak for the clinical question. Their system rebuilds images as data arrives and tracks uncertainty in the final measurement, such as cartilage volume or heart ejection fraction. Conformal prediction turns that uncertainty into a calibrated confidence interval.
The scan ends when the interval meets a set precision target. Tested on knee and cardiac data, the method cut scan times versus fixed protocols while keeping statistical guarantees on accuracy.
Catalog record
| CREATOR | Paul Fischer, Jan Nikolas Morshuis, Thomas Küstner, Christian Baumgartner |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 47 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-14952
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
CUTE-MRI: Conformalized Uncertainty-based framework for Time-adaptivE MRI Journal: Medical Image Analysis Paul Fischer, Jan Nikolas Morshuis, Thomas Küstner, Christian Baumgartner Abstract Magnetic Resonance Imaging (MRI) offers unparalleled soft-tissue contrast but is fundamentally limited by long acquisition times. While deep learning-based accelerated MRI can dramatically shorten scan times, the reconstruction from undersampled data introduces ambiguity resulting from an ill-posed problem with infinitely many possible solutions that propagates to downstream clinical tasks. This uncertainty is usually ignored during the acquisition process as acceleration factors are often fixed a priori , resulting in scans that are either unnecessarily long or of insufficient quality for a given clinical endpoint. This work introduces a dynamic, uncertainty-aware acquisition framework that adjusts scan time on a per-subject basis. Our method leverages a probabilistic reconstruction model to estimate image uncertainty, which is then propagated through a full analysis pipeline to a quantitative metric of interest (e.g., patellar cartilage volume or cardiac ejection fraction). We use conformal prediction to transform this uncertainty into a rigorous, calibrated confidence interval for the metric. During acquisition, the system iteratively samples k-space, updates the reconstruction, and evaluates the confidence interval. The scan terminates automatically once the uncertainty meets a user-predefined precision target. We validate our framework on both knee and cardiac MRI datasets. Our results demonstrate that this adaptive approach reduces scan times compared to fixed protocols while providing formal statistical guarantees on the precision of the final image. This framework moves beyond fixed acceleration factors, enabling patient-specific acquisitions that balance scan efficiency with diagnostic confidence, a critical step towards personalized and resource-efficient MRI. 1 Introduction Magnetic Resonance Imaging (MRI) is a cornerstone of modern medical diagnostics. Its ability to non-invasively generate images with exceptional soft-tissue contrast makes it indispensable for the diagnosis, staging, and monitoring of a wide range of diseases, from neurological disorders to musculoskeletal injuries and cardiovascular conditions [ 1 ] . However, the high diagnostic value of MRI is often counterbalanced by its inherently long acquisition times. These lengthy scans can lead to patient discomfort, increase the likelihood of motion artifacts that degrade image quality, and limit patient throughput, thereby increasing operational costs and wait times [ 2 ] . Consequently, accelerated MRI techniques, which aim to reconstruct high-quality images from undersampled k-space data, are of paramount importance for making MRI more efficient, cost-effective, and patient-friendly [ 3 , 4 ] . While accelerated MRI promises to alleviate these challenges, the majority of current methods, both in clinical practice and in research, rely on static acquisition strategies [ 3 , 4 , 5 ] . These approaches employ fixed, pre-determined undersampling rates that are designed offline and are not adapted to the specific patient. This inflexibility represents a central, unaddressed limitation: the acquisition process remains agnostic to the content and complexity of the image being formed. This can lead to a suboptimal use of scanner time, as less data may be sufficient, especially when a specific downstream metric is the primary interest. The evolution of accelerated MRI has been marked by two major paradigms. The first encompasses classic reconstruction techniques, such as parallel imaging and compressed sensing, while the second is defined by the rise of deep learning (DL). Classic methods, rooted in parallel imaging (e.g., SENSE, GRAPPA) and compressed sensing (CS), leverage explicit priors like signal sparsity to recover images from limited data [ 3 , 6 , 7 ] . While they provide a strong theoretical foundation, their performance tends to degrade at high acceleration factors, where severe aliasing artifacts can become diagnostically prohibitive. In contrast, the second paradigm of deep learning has revolutionized the field. Models trained on large datasets learn complex, implicit priors and have demonstrated high-quality reconstructions, even from highly undersampled data [ 8 , 9 , 10 , 11 ] . These methods often outperform traditional techniques in terms of pure reconstruction quality and speed. Despite their impressive performance, deep learning models often function as "black boxes," and their predictions come with no inherent guarantees of correctness. This can lead to a critical problem of misplaced trust, where models may produce plausible-looking but factually incorrect reconstructions, a phenomenon often termed "hallucination" [ 12 , 13 , 14 ] . The risk is particularly acute in the ill-posed problem of MR reconstruction, where uncertainty arises not only from the missing k-space measurements but also from physiological and anatomical variability between patients, pathologies, and motion. This unquantified uncertainty does not just affect the reconstructed image; it can silently propagate to and corrupt downstream clinical tasks, such as segmentation, registration, or disease classification, that rely on these images for diagnosis and treatment planning [ 15 , 16 ] . Recognizing this challenge, a growing body of research has focused on uncertainty quantification (UQ) for deep learning in medical imaging. Various methods, such as Bayesian neural networks, ensembles and variational autoencoder-based methods have been developed to estimate model uncertainty [ 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 ] . Several works have successfully demonstrated how this uncertainty can be propagated from the reconstruction to a downstream task to provide a more complete picture of diagnostic confidence [ 15 , 26 ] . However, while significant research has focused on estimating and propagating uncertainty for post-hoc analysis, its potential to actively guide and optimize the MRI acquisition process itself in real-time remains largely unexplored. Daudé et al. [ 27 ] proposed an adaptive method where scan quality, specifically the Signal-to-Noise Ratio SNR, is estimated periodically during acquisition. The scan is terminated once the SNR surpasses a pre-defined quality threshold, enabling personalized scan durations. However, this approach relies on a classical, signal-based metric and does not account for the reconstruction uncertainty or potential for artifacts, such as hallucinations, common in modern learning-based methods. Pineda et al. [ 28 ] for example analyzed how to find the optimal sampling trajectory for accelerated MR acquisition using reinforcement learning, however they did not consider the effect of downstream applications. Wang et al. [ 29 ] jointly analyzed the influence of k-space acquisition and segmentation quality by iteratively sampling k-space up to a fixed undersampling rate such that segmentation quality is as high as possible. However, this work does not account for the inherent uncertainty in the pipeline, nor does it assess when there is sufficient k-space data.. It becomes apparent that prior work on optimizing scan duration has typically focused on pre-calculating sampling trajectories or defining stopping criteria based on image-level metrics, without considering model confidence along the diagnostic pipeline [ 30 , 31 ] . This reveals a critical gap: current static acquisition protocols are inherently inefficient. They may waste valuable scanner time on anatomically “easy” cases that could have been reconstructed with sufficient quality from fewer measurements, or conversely, they may terminate prematurely for “hard” or unusual cases, yielding diagnostically inadequate images. This one-size-fits-all approach fails to account for the simple fact that some diagnostic tasks or anatomies do not require perfectly reconstructed images to yield clinically reliable results. In this work, we show that by monitoring the uncertainty of a reconstruction model and its downstream clinical application, one can create a patient-specific, adaptive stopping rule for k-space acquisition. The