Enhancing Neutron Measurement Accuracy with Bubble Detectors at Laser-Driven Neutron Sources
Stefan Scheuren, M. Ángeles Millán-Callado, Jonas Kohl, Tim T. Jäger, Markus Roth, Christian Rödel, Aaron Alejo, Florian Kroll, Karl Zeil, Arnd Junghans, Carlos Guerrero, Benedikt Schmitz · 2025
Read Enhancing Neutron Measurement Accuracy with Bubble Detectors at Laser-Driven Neutron Sources by Stefan Scheuren, M. Ángeles Millán-Callado, Jonas Kohl, Tim T. Jäger, Markus Roth, Christian Rödel, Aaron Alejo, Florian Kroll, Karl Zeil, Arnd Junghans, Carlos Guerrero, Benedikt Schmitz (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-14463.txt.
Introduction
Stefan Scheuren and co-authors write a 2025 paper on measuring neutrons from laser-driven sources. Bubble detectors count neutrons well even amid fierce gamma rays and electric pulses. Their response shifts with neutron energy, though, which can skew the flux readings that labs report.
The team rebuilt the detector response as a function of energy using a fitted surrogate model. Blending that curve with the expected neutron spectrum gives one clean response value for a shot. On data from a petawatt laser, the new method cut flux estimates by up to about thirty percent versus older practice. Results matched deep simulations within ten percent. The authors also flag scattering as a large share of what the detectors see.
Catalog record
| CREATOR | Stefan Scheuren, M. Ángeles Millán-Callado, Jonas Kohl, Tim T. Jäger, Markus Roth, Christian Rödel, Aaron Alejo, Florian Kroll, Karl Zeil, Arnd Junghans, Carlos Guerrero, Benedikt Schmitz |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 64 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-14463
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Enhancing Neutron Measurement Accuracy with Bubble Detectors at Laser-Driven Neutron Sources Preprint: AIP/123-QED Stefan Scheuren, M. Ángeles Millán-Callado, Jonas Kohl, Tim T. Jäger, Markus Roth, Christian Rödel, Aaron Alejo, Florian Kroll, Karl Zeil, Arnd Junghans, Carlos Guerrero, Benedikt Schmitz Abstract Bubble detectors are widely used to measure neutron flux from laser-driven sources employing a pitcher-catcher setup, due to their insensitivity to intense γ \gamma -ray backgrounds and strong electromagnetic pulses (EMP). This paper presents a method to account for the neutron energy-dependent response of bubble detectors, enabling accurate conversion of bubble counts into neutron flux at the detector location. The proposed method is based on the accurate reconstruction of the response function using a surrogate model. The resulting model is convoluted with the (normalized) expected/measured neutron spectrum to obtain an effective measure of the bubble detector’s response, herein referred to as effective c c or c eff c_{\text{eff}} . This effective value for the response is energy-independent after the convolution. In this way, our approach includes the spectral distribution of neutrons arriving at the detector to determine the integral neutron flux. Analyzing our experimental results obtained at the DRACO PW laser and comparing the results to previously used methods to obtain neutron fluxes from bubble detectors returns a reduction in neutron flux of up to 31 % 31\text{\,}\% . Results from the method detailed in this paper agree with in-depth experimental setup Monte Carlo simulations, with deviations of less than 10 % 10\text{\,}\% . We furthermore discuss the inherent limitations of our method with regard to its uncertainty and highlight the influence of neutron scattering in bubble detector measurements. For our experimental setup at the DRACO laser, up to 47 % 47\text{\,}\% of the detected neutrons arrive at the detector after undergoing at least one scattering event. I Introduction Laser-driven neutron sources (LDNS) have made great strides forward in recent years Alvarez et al. 2014 ; Alejo et al. 2016 ; Yogo et al. 2023a with first demonstrations of non-destructive sample analysis, employing different neutron measurement techniques Zimmer et al. 2022 ; Yogo et al. 2023b . LDNS commonly use the pitcher-catcher scheme Lancaster et al. 2004 , in which protons are accelerated by directing an ultrahigh-intensity laser pulse onto a laser target, usually a thin (nm to \upmu m thickness) metal or plastic foil, the so-called pitcher. In this way, protons can be accelerated to several tens of \mathrm{M}\mathrm{e}\mathrm{V} through the so-called target normal sheath acceleration Snavely et al. 2000 ; Wilks et al. 2001 (TNSA) mechanism. It needs to be mentioned that TNSA does not generate a pure proton beam. Instead, due to the complex acceleration mechanics, other ion species can also be accelerated, and MeV electrons and photons accompany the ion beam Passoni, Bertagna, and Zani 2010 ; McKenna et al. 2013 . Subsequently, the ions are directed onto a suitable converter material Kar et al. 2016 (the catcher), often beryllium Roth et al. 2013 ; Kleinschmidt et al. 2018 ; Yogo et al. 2023b , copper Roth et al. 2013 ; Pomerantz et al. 2014 , or lithium-fluoride Lancaster et al. 2004 ; Zimmer et al. 2022 , where neutrons are generated via nuclear reactions. Due to their unique characteristics, such as small form factor, high peak flux, and short primary neutron pulse duration, these sources have been of immense interest as a promising alternative to high-intensity conventional accelerator-based neutron sources Alvarez et al. 2014 ; Alejo et al. 2016 ; Yogo et al. 2023a . One drawback of LDNS is the high noise environment they generate, such as a prompt electromagnetic pulse (EMP) interfering with detection and data acquisition systems Bradford et al. 2018 ; Seimetz et al. 2020 or the high x-ray/ \gamma -ray background, as many different interaction processes take place within the laser pulse duration (typically \lesssim$1\text{\,}\mathrm{p}\mathrm{s}$ ). Also important to note is that due to its short acceleration time all of the generated neutrons come at once generating a high instantaneous neutron flux and results in a pile up inside of electronic detectors. Since the current repetition rate of laser systems is relatively low, only single shot diagnostics are necessary to be used so far. Due to this high noise environment interfering with the measurement, it remains a challenge to determine absolute neutron numbers accurately at these sources within reasonable time frames. To circumvent these limitations, the community has adopted Bubble Detectors Ing and Birnboim 1984 ; Ing, Noulty, and McLean 1997 (BDs) manufactured by Bubble Technology Industries (BTI) to measure the integral fast neutron flux per solid angle. The radiation field outside of the vacuum chamber only consists of neutron and gamma signals, while ions and charges particles are stopped in the chamber walls. The BDs’ are insensitive to gamma radiation, because they rely on a kinematic detection approach. In short, BDs are filled with a polymer gel which contains super-heated halogen and/or hydrocarbon droplets. When a neutron interacts with a BD, energy is deposited inside the gel. The droplet vaporizes if the deposited energy exceeds a threshold, leaving a visible bubble behind. The energy threshold is dependent on the manufacturing process and can range from 10\text{\,}\mathrm{keV}10\,000\text{\,}\mathrm{keV} Bubble Technology Industries 2023 . Gammas do not deposit as much energy inside the gel, such that they can be assumed to be insensitive to gammas Smith et al. 2014 ; Bubble Technology Industries 2023 . The generated bubbles can therefore be counted and translated into a neutron dose. Their original purpose was to be used as a personal neutron dosimeter. However, the kinetic approach to detection makes the detectors highly suitable for the environment present at laser-driven neutron sources. Therefore, bubble detectors have emerged as on of the most used diagnostic for measuring and comparing neutron yields at LDNS Mirfayzi et al. 2015 ; Yogo et al. 2023a . They are insensitive to these sources’ harsh \gamma noise environment and their dominant EMP, as their deposited energy is too low to trigger the bubble formation inside the contained superheated liquid. To calculate the neutron number \hat{N} from a count of bubbles b , Equation 1 is used Kleinschmidt et al. 2018 \displaystyle\hat{N}=\frac{b\cdot d^{2}}{\hat{c}_{\text{avg}}\cdot s_{0}},\text{ with }\left[\hat{N}\right]=\frac{1}{\text{sr}}, (1) where d is the distance from the source to the detector in cm, s_{0} is the sensitivity of the bubble detector in bubbles per mrem and \hat{c}_{\text{avg}} is based on the neutron energy-dependent response function \hat{c}(E_{\text{n}}) of the bubble detector. However, since BDs measure the integral neutron flux, the energy distribution of the neutrons at the position of the detector is unknown. For this reason \hat{c}(E_{\text{n}}) is commonly approximated by averaging the response function over the energy region of interest, with often-used values ranging from \hat{c}_{\text{avg}}=$3.03.5\text{\,}\mathrm{b}\mathrm{u}\mathrm{b}\mathrm{b}\mathrm{l}\mathrm{e}\mathrm{s}\cdot\mathrm{c}\mathrm{m}^{2}\mathrm{/}\mathrm{n}\mathrm{e}\mathrm{u}\mathrm{t}\mathrm{r}\mathrm{o}\mathrm{n}$ Pomerantz et al. 2014 ; Kleinschmidt et al. 2018 ; Treffert 2023 for 1\text{\,}\mathrm{b}\mathrm{u}\mathrm{b}\mathrm{b}\mathrm{l}\mathrm{e} per mrem Jung et al. 2013 . This approach can result in the incorrect estimation of neutron numbers, as the calculation neglects the influence of the spectral distribution of the generated neutron beam. As shown later, the amount of scattered neutrons is also to be considered since this leads to multiple counts of the same neutrons with different bubble counts. In this work, we present a method to account for the energy dependence of the