Polarization-Resolved Chlorophyll Imaging for Non-Invasive Plant Tissue Assessment Using a Silicon-Rich Nitride Metalens Array

Alireza Khalilian, Mehdi Sh. Yeganeh, Konstantin Tsoi, Bowen Yu, Joe Lo, Yasha Yi · 2025

Read Polarization-Resolved Chlorophyll Imaging for Non-Invasive Plant Tissue Assessment Using a Silicon-Rich Nitride Metalens Array by Alireza Khalilian, Mehdi Sh. Yeganeh, Konstantin Tsoi, Bowen Yu, Joe Lo, Yasha Yi (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-14191.txt.

Introduction

Alireza Khalilian and five co-authors build a flat-lens camera for plant health checks in a 2025 paper. Imaging that reads light polarization reveals tissue structure that plain brightness images miss, but the optics are bulky. Their array of tiny lenses, made from a silicon-rich material, captures two polarization directions at once at the exact color where chlorophyll absorbs. Chips are made with standard chip-factory processes.

Fused and difference maps showed structure direction and pigment variation in healthy and stressed leaves. The lenses reach high sharpness and light throughput while staying compact. The team presents the device as a scalable route to early, label-free detection of plant stress.

Catalog record

CREATORAlireza Khalilian, Mehdi Sh. Yeganeh, Konstantin Tsoi, Bowen Yu, Joe Lo, Yasha Yi
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE30 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2508-14191

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Polarization-Resolved Chlorophyll Imaging for Non-Invasive Plant Tissue Assessment Using a Silicon-Rich Nitride Metalens Array Alireza Khalilian, Mehdi Sh. Yeganeh, Konstantin Tsoi, Bowen Yu, Joe Lo, Yasha Yi Abstract Polarization-sensitive imaging enhances contrast and reveals structural features in biological tissues that are often missed by intensity-based methods, but its adoption is limited by bulky optics. We present a compact silicon-rich nitride (SRN) metalens array for high-resolution, polarization-resolved imaging of plant tissue at the chlorophyll absorption peak (660 nm). The array integrates orthogonally sensitive metalenses to simultaneously capture X- and Y-linearly polarized transmission images, enabling real-time, label-free assessment of plant microstructure and stress responses. Polarization fusion and difference mapping reveal structural anisotropy and pigment variation in both healthy and stressed leaves. The SRN metalens, designed via an inverse approach using birefringent meta-atoms and fabricated through CMOS-compatible processes, achieves a large numerical aperture, high transmission, and spectral alignment with biological absorbers. This work demonstrates the feasibility of compact, integrated polarization-resolved imaging, offering a scalable alternative to conventional systems. The approach holds potential for biomedical and agricultural applications, where detecting subtle polarization-dependent changes could enable early diagnosis and tissue characterization. keywords Polarization, tissue imaging, siliocn-rich nitride, Metalens, CMOS compatible Introduction Imaging biological tissue is crucial for identifying early indicators of disease and understanding the progression of physiological disorders. Optical imaging is particularly valuable due to its ability to provide internal insights without causing physical harm. As a non-invasive approach, it enables real-time monitoring in diverse biological and clinical contexts. Over the years, a range of optical imaging techniques has been developed to address this need, including fluorescence microscopy, confocal microscopy, and hyperspectral imaging Xu et al. 2024 ; Lai et al. 2024 . Among current methods, polarization-sensitive imaging is notable for its ability to reveal structural and functional attributes frequently missed by conventional intensity- or spectrum-based techniques Tang and Wang 2020 . Subtle characteristics such as tissue anisotropy, fiber orientation, and stress-induced modifications can be elucidated by examining the impact of polarized light on tissue, encompassing birefringence, depolarization, and dichroism Suzuki et al. 2025 . However, relying solely on intensity or spectral imagery often fail to adequately disclose these attributes Oldenbourg 1996 ; Jermain et al. 2024 . This feature is especially effective for assessing plant health, offering a biologically relevant but experimentally accessible framework to illustrate the benefits of polarization-resolved imaging. Plants exhibit characteristic polarization responses arising from their internal microstructure and natural birefringence, which can change in magnitude or pattern under stress or nutritional deficiencies Rodríguez et al. 2022 ; Li et al. 2022 . Such conditions often alter chloroplast organization, cell wall structure, and pigment content, all of which influence both polarization signatures and photosynthetic performance Van Eeckhout et al. 2021 . Chlorophyll, the primary pigment driving photosynthesis, strongly absorbs light near \lambda=660\,\mathrm{nm} and \lambda=680\,\mathrm{nm} , making these wavelengths particularly suitable for assessing its concentration and spatial distribution Lichtenthaler and Buschmann 2001 . While tools such as SPAD meters and spectrophotometers are frequently used to evaluate chlorophyll content, they have notable limitations. A SPAD (Soil Plant Analysis Development) meter is a handheld device that estimates relative chlorophyll concentration by measuring leaf transmittance at two wavelengths, but it is confined to small, localized measurement areas. Spectrophotometry, in contrast, often requires destructive sample preparation Wicharuck et al. 2024 ; Chazaux et al. 2022 . Hyperspectral imaging systems can provide extensive spectral information; however, their size, cost, and operational complexity often restrict their use to controlled laboratory environments Zolotukhina et al. 2023 . In contrast, polarization-resolved imaging facilitates label-free, spatially resolved evaluations of chlorophyll and tissue structure through the use of compact setups. Even simplified dual-polarization approaches—relying on orthogonal linear states—can uncover significant distinctions through differential analysis methods, such as absolute or signed difference mapping Rodríguez et al. 2022 . The methods emphasize characteristics that traditional techniques might miss, enhancing the contrast between stressed and healthy areas and facilitating subsequent image processing by offering insights into tissue orientation and structural integrity Van Eeckhout et al. 2021 . To improve the accessibility and scalability of polarization-resolved imaging, recent research efforts have focused on metasurface optics. Metalenses—ultrathin optical components made from carefully designed subwavelength nanostructures—offer precise control over the phase, amplitude, and polarization of light, all within a compact and lightweight form factor Li et al. 2025 ; Chen et al. 2025 ; Fu et al. 2025 . Their planar geometry and compatibility with common lithographic fabrication techniques render them especially suitable for integration into portable imaging devices and CMOS-based platforms. Nonetheless, the broader adoption of metalenses has been hindered by material and fabrication limitations. Commonly used materials— such as titanium dioxide (TiO 2 ) Li et al. 2025 , amorphous silicon (a-Si) Zhang et al. 2022 , and gallium nitride (GaN) Chen et al. 2021 , often require fabrication steps that are either too complex or not compatible with standard CMOS processes, making them less suitable for large-scale production. Silicon-rich nitride (SRN) has recently drawn interest as a practical material for metalens fabrication. It offers a high refractive index, minimal optical loss in the visible range, and strong compatibility with standard CMOS processes Goldberg et al. 2024 ; Khalilian et al. 2025 . These features make SRN a compelling choice for creating metalenses that are both efficient and easier to scale—qualities that are important for transitioning from lab-scale demonstrations to real-world applications in research and industry Fröch et al. 2025 ; Ye et al. 2019 . This study presents a high-numerical-aperture (NA) metalens array fabricated using silicon-rich nitride (SRN), carefully designed for dual-polarization imaging utilizing orthogonal linear polarization states (XLP and YLP). We demonstrate its potential via chlorophyll absorption imaging, serving as a proof of concept for non-invasive evaluation of plant tissue characteristics. By combining SRN’s CMOS-compatible fabrication with the structural sensitivity of polarization imaging, the resulting platform offers a lightweight, scalable, and biologically relevant solution with broad applicability in precision agriculture, environmental monitoring, and biomedical diagnostics. 1 Metalens Design Methodology A high-numerical-aperture (NA) metalens was designed to operate at a wavelength of \lambda=660\,\mathrm{nm} . The focusing function was achieved by implementing a spatially varying phase mask, where each point on the lens surface introduces a specific phase delay to shape the transmitted wavefront into a diffraction-limited focus. The target phase distribution follows a hyperboloidal profile (Figure 1 (g)), \Phi(x,y)=\frac{2\pi}{\lambda}\!\left(f-\sqrt{f^{2}+x^{2}+y^{2}}\right), (1) which ensures constructive interference at the focal plane. With \mathrm{NA}=0.5 , the calculated focal length is f\approx 52.7\,\mu\mathrm{m} . Figure 1: (a, c) Simulated phase shift maps for XLP and YLP, and (b, d) transmission maps for the XLP and YLP lens, respectively. (e) Measured refractive index ( n ) and extinction coefficient ( k ) of SRN films for different deposition recipes (R denotes recipe). (f) Schematic of a meta-atom. (g) Target phase profile and 3D lens layout. The lens aperture was divided into a square grid containing 156\times 156 meta-atoms, each separated by a pitch of 390\,\mathrm{nm} , giving an effective aperture diameter of about 60.8\,\mu\mathrm{m} . The meta-atom geometries were parameterized by their lateral dimensions - length ( l ) and width ( w ) with fixed height (H) of 600\,\mathrm{nm} (Figure 1 (f)) - and selected from a simulation library generated using Lumerical FDTD. This library was obtained by sweeping

Read the complete text