Microscopic magnetic field imaging with hot atoms via single-pixel imaging

Cyril Torre, Jordan Brass, Sebastien Bisdee, Mohammed T. Rasheed, Giacomo Ferranti, Carrie A. Weidner · 2025

Read Microscopic magnetic field imaging with hot atoms via single-pixel imaging by Cyril Torre, Jordan Brass, Sebastien Bisdee, Mohammed T. Rasheed, Giacomo Ferranti, Carrie A. Weidner (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-13869.txt.

Introduction

Cyril Torre and five co-authors image microscopic magnetic fields using hot atomic vapor and a single-pixel camera in this 2025 paper. Vapor cell sensors are compact and sensitive field meters, used even in the field on living systems. But their images were blurry, limited by the sensor's own size.

The team combined the vapor sensor with single-pixel imaging, which rebuilds a picture from patterned light and one detector. A projector's pattern set the resolution, reaching about sixty micrometers. The lack of magnetic shielding also capped the sharpness. The work shows quantum sensors can deliver microscope-scale field maps. Such maps could serve biology and materials checks where fields vary over tiny distances.

Catalog record

CREATORCyril Torre, Jordan Brass, Sebastien Bisdee, Mohammed T. Rasheed, Giacomo Ferranti, Carrie A. Weidner
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE29 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2508-13869

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Microscopic magnetic field imaging with hot atoms via single-pixel imaging Cyril Torre, Jordan Brass, Sebastien Bisdee, Mohammed T. Rasheed, Giacomo Ferranti, Carrie A. Weidner Abstract In recent years, sensors based on hot atomic vapor cells have emerged as a compact and highly sensitive means of measuring magnetic fields. Such sensors have been deployed in the field for the measurement of, e.g. biological systems, representing a promising practical application of quantum technologies. However, it remains challenging to obtain high-resolution magnetic field images from these sensors, and in most cases the spatial resolution of the system is limited by the sensor size. Here, we demonstrate the combination of single-pixel imaging (SPI) techniques with an atom vapor Faraday magnetometer to achieve microscopic magnetic field imaging. We demonstrate magnetic field imaging with a spatial resolution of ≈ 62.5 µ ​ m \approx\penalty\ $62.5\text{\,}\mathrm{\SIUnitSymbolMicro m}$ , limited only by the resolution of our DMD projection system and the absence of magnetic shielding in our experimental setup. I Introduction Atomic sensors have proven to be among the most sensitive for measuring magnetic fields, achieving subfemtotesla sensitivity Kominis2003 ; Dang2010 ; Ledbetter2008 . High-resolution, high-sensitivity imaging of magnetic fields is thus a logical next step in the development of this technology. A demonstration of magnetic field imaging using ultracold atoms achieved a spatial resolution of 3\text{\,}\mathrm{\SIUnitSymbolMicro m} and a sensitivity of 300\text{\,}\mathrm{pT} BEC_MfieldImaging . However, cold atom systems require relatively complex, bulky experimental systems, and compactification of such systems into something suitable for practical applications remains challenging. In addition, one must trap the cold atoms close enough to the sample in order to sense the magnetic field, rendering biological applications particularly challenging. With the recent emergence of hot atomic vapor cells, the experimental apparatus can be dramatically simplified while maintaining high sensitivity up to a few \text{\,}\mathrm{fT}\text{\,}{\mathrm{}}^{-1} with a miniature millimetre-scale Rubidium (Rb) vapor cell Kitching2007 ; Compact_mag ; Griffith2010 . Vector magnetometry with \text{\,}\mathrm{pT}\text{\,}{\mathrm{}}^{-1} sensitivities have been demonstrated in hot atom vapor Fernholz2019 . Such systems have also been made compact and portable, demonstrating magnetic field sensing from biological sources, such as the brain Brookes2022 , the heart Dawson2023 or the eyes Westner2021 . However, demonstrations of magnetic field imaging using hot atoms have been, to-date, limited. A CCD camera has been used to image atoms and detect magnetic field variations per 10\times$10\text{\,}\mathrm{\SIUnitSymbolMicro m}$ pixel Narducci2009 . Arrays of microfabricated optically-pumped magnetometers (OPMs) have been used for highly sensitive (tens of \text{\,}\mathrm{fT}\text{\,}{\mathrm{}}^{-1} ) magnetic field imaging Knappe2017 , but their resolution is fundamentally limited by the magnetometer system size. Other methods produced images by scanning a 100\text{\,}\mathrm{\SIUnitSymbolMicro m} -scale beam across a vapor cell Riis2023 . Microwave field imaging with micrometer spatial resolution has been achieved in alkali vapor Treutlein2012 ; Treutlein2015 ; Prajapati2024 ; this method was also extended to DC field imaging Mileti2015 . In this work, we propose combining vapor cell magnetometry with single-pixel imaging (SPI) techniques Duarte2008 . In particular, as our measurement is the polarization rotation of light passing through the cell via the Faraday effect Schatz1969 , we implement SPI polarimetry Lancis2012 ; Padgett2015 ; Zhao2020 ; Foreman2020 ; Wang2022 as a means of generating the magnetic field images. A detailed review of SPI can be found in Ref. Gibson2020 . The SPI technique involves measuring the transmitted light intensity through the sample for a series of known patterns projected by a spatial light modulator, usually a digital micromirror device (DMD). The resulting transmitted intensities, recorded on a photodetector, are then weighted according to the corresponding DMD patterns to reconstruct the image Gibson2020 . A key advantage of this method is that DMDs are relatively compact and can be easily integrated to most hot atom vapour magnetometer technologies. Furthermore, photodetector technology is well-established, offering a high quantum efficiency and low noise floor, making this system amenable to eventual use with light sources operating below the shot noise limit Wolfgramm2010 ; Horrom2012 ; Bai2021 . This paper is organized as follows: We present relevant theory in Sec. II before describing the experiment in Sec. III . Results follow in Sec. IV , and Sec. V concludes. II Theory Our chosen basis for the implementation of SPI is the set of differential Hadamard patterns, as they offer a higher signal-to-noise ratio performance compared to other patterns SPIFvsH . These are defined by a series of Hadamard matrices, where the Hadamard matrix of dimension two can be defined by H_{2}=\left(\begin{matrix}1&1\\ 1&-1\end{matrix}\right). (1) To reconstruct an image with a spatial resolution of n\times n pixels, all patterns can be generated using a single Hadamard matrix of dimension n^{2} , where: H_{n^{2}}=\left(\begin{matrix}H_{n^{2}/2}&H_{n^{2}/2}\\ H_{n^{2}/2}&-H_{n^{2}/2}\end{matrix}\right)=H_{2}\otimes H_{n^{2}/2}, (2) and n is a power of 2 . Each pattern corresponds to H_{n^{2}} , a single row of dimension 1\times n^{2} , to be afterward reshaped into a n\times n binary matrix and to be loaded into the DMD. Because the DMD cannot project a negative intensity, each pattern needs to be projected twice, first by projecting the positive value as 1 and negative as 0 , and vice versa. Hadamard matrices are unitary and invertible, forming an orthogonal basis. Therefore, an image s_{n\times n} can be easily mathematically reconstructed from the measured intensities of each pattern, I_{\pm} , which are vectors of dimension n^{2}\times 1 corresponding to the positive and negative patterns, respectively. Hence, we have: s_{n\times n}=(H_{n^{2}}^{+}-H_{n^{2}}^{-})^{-1}.(I_{+}-I_{-}), (3) where s_{n\times n} is a vector of dimension n^{2}\times 1 that needs to be reshaped into an n\times n matrix, representing the reconstructed image of the sample. The magnetic field is sensed via the Faraday effect, also known as Faraday rotation (FR) Schatz1969 . This phenomenon is described by a rotation of the incident linear polarization transmitted through a medium in the presence of a magnetic field. Mathematically, we have \Phi=BLv, (4) where \Phi is the rotation of the polarization of the input light, B the magnetic field, L the length of the medium (here the vapor cell), and v the Verdet constant, which is a wavelength-dependent optical property of a given medium. The Verdet constant needs to be calibrated prior to any magnetic field sensing. It sets the sensitivity of the magnetometer, but is also sensitive to temperature, frequency of the probe, and the external magnetic field Bai2021 . Indeed, if the magnetic field is too strong, the energy levels of the rubidium atoms in the vapor cell will shift, leading to a change in the Verdet constant. Therefore in this work, Helmholtz coils are used to add a bias on the magnetic field surrounding the cell in order to zero the mean field produced by the sample and ensure the same sensitivity within the range of the magnetic field produced by the sample. III Experimental Setup III.1 Experiment description The experimental setup is illustrated in Fig. 1 . A 795\text{\,}\mathrm{nm} pigtailed DBR laser ( DBR795PN , Thorlabs ) is first split by a 90:10 beamsplitter (BS). The 10\% of light that is picked off is used to lock the laser onto the F=2 to F^{\prime}=2 transition of the D1 line of 87 Rb via polarization spectroscopy locking freq_locking (see Appendix A for further details). FIG. 1: Microscopic magnetic field imaging experimental setup. A DBR laser ( DBR795PN ,

Read the complete text