Read Susceptibility Distortion Correction of Diffusion MRI with a single Phase-Encoding Direction by Sedigheh Dargahi, Sylvain Bouix✉, Christian Desrosiers (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-13340.txt.

Introduction

Sedigheh Dargahi, Sylvain Bouix, and Christian Desrosiers built a learning tool in 2025 that unwarps brain diffusion scans taken in only one direction. Such scans map the brain's wiring by tracking water movement, but the fast imaging they need bends shapes and brightness. The standard fix demands paired scans taken in opposite directions, which old datasets lack.

Their network takes the single available scan and predicts the corrected image on its own. In experiments, its results matched the paired-scan gold standard closely. That opens the fix to the huge store of past scans taken one way only. The authors pitch the tool as a practical rescue for shared data. It could also shorten new scan sessions where time is tight.

Catalog record

CREATORSedigheh Dargahi, Sylvain Bouix✉, Christian Desrosiers
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE25 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2508-13340

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Susceptibility Distortion Correction of Diffusion MRI with a single Phase-Encoding Direction Sedigheh Dargahi, Sylvain Bouix✉, Christian Desrosiers Abstract Diffusion MRI (dMRI) is a valuable tool to map brain microstructure and connectivity by analyzing water molecule diffusion in tissue. However, acquiring dMRI data requires to capture multiple 3D brain volumes in a short time, often leading to trade-offs in image quality. One challenging artifact is susceptibility-induced distortion, which introduces significant geometric and intensity deformations. Traditional correction methods, such as topup \mathrm{topup} , rely on having access to blip-up and blip-down image pairs, limiting their applicability to retrospective data acquired with a single phase encoding direction. In this work, we propose a deep learning-based approach to correct susceptibility distortions using only a single acquisition (either blip-up or blip-down), eliminating the need for paired acquisitions. Experimental results show that our method achieves performance comparable to topup \mathrm{topup} , demonstrating its potential as an efficient and practical alternative for susceptibility distortion correction in dMRI. 1 Introduction Among neuroimaging techniques, diffusion MRI (dMRI) plays a crucial role in understanding the complex connectivity and microstructural features of the brain [ 1 ] . The acquisition of dMRI data involves two key considerations. First, special gradient fields are applied during data collection to make the image sensitive to diffusion in a specific direction. Second, to acquire the needed information, many separate 3D images of the brain must be obtained, as each 3D image provides information about diffusion in just one direction. Consequently, to acquire dMRI data in a reasonable amount of time--typically a few minutes--fast imaging sequences such as Echo Planar Imaging (EPI) are used. Unfortunately, these fast acquisitions often lead to image artifacts, which need to be addressed in post-processing. One of the main artifacts, known as susceptibility distortion , changes the geometry of the brain along the phase encoding (PE) direction. When dealing with susceptibility-induced distortions, both traditional and deep learning (DL) techniques have been developed. One of the popular strategies is to acquire reversed-phase encoding directions from which a field map can be estimated (the \mathrm{topup} tool in FSL) [ 2 ] . In recent years, several deep learning-based susceptibility distortion correction techniques [ 3 , 4 ] have emerged to correct this kind of distortion faster and more accurately than \mathrm{topup} [ 5 ] . In [ 6 ] , an unsupervised U-Net minimizes the difference between unwarped images at multiple resolutions to accelerate processing. The approach in [ 7 ] uses fiber orientation distributions (FODs) derived from dual-phase dMRI and applies a U-Net (DrC-Net) for correction. FOD estimation is computationally intensive, as it requires fitting high-order spherical harmonic models at each voxel to resolve crossing fibers. When applied to millions of voxels in multi-shell diffusion data, this results in substantial computational demands. [ 8 ] employs PSF-EPI images as ground truth for training a correction network, yet this data is rarely acquired in clinical practice. A common challenge of these methods is the dependence on blip-up and blip-down acquisitions, which are not always available. This reliance limits the broader use of advanced distortion correction techniques. Developing a method that works across different scenarios and data types would thus make distortion correction more accessible and practical for both clinical use and research settings. One of the promising DL method [ 3 ] addresses this problem by synthesizing an undistorted EPI image from a structural T1-Weighted (T1w) scan and a single-blip diffusion image. The single-blip image and synthetized image are then used as input to \mathrm{topup} to estimate a field map. However, training this method relies on having access to a dataset containing undistorted multi-shot diffusion b0 images paired with single-blip data, which are not commonly acquired. Additionally, \mathrm{topup} is still needed to estimate the field map. In this work, we introduce a slice-wise deep-learning method designed to correct susceptibility distortions in dMRI using only a single phase-encoding direction , addressing a limitation in current distortion correction techniques. Our contributions can be summarized as follows. First, unlike traditional approaches such as [ 2 ] , which require paired acquisitions, our method needs only one phase-encoded distorted dMRI image alongside a corresponding structural T1w image. This broadens the practical applicability, particularly for retrospective datasets where dual-phase acquisitions are not available. Second, our model simultaneously predicts both the Voxel Displacement Map (VDM) and the intensity-corrected b0 image in a single forward pass, simplifying the correction workflow. Finally, by integrating these ideas, we reduce processing times from several minutes typically needed by well-known methods such as Synb0 [ 3 ] to mere seconds, facilitating large-scale studies and time-sensitive applications. Experimental results demonstrate that our method not only provides correction quality close to that of dual-phase methods like topup, but also surpasses existing single-phase technique in both accuracy and speed. 2 Method As illustrated in Figure 1 , the proposed model takes as input distorted blip-up or blip-down b0 images 1 1 1 Without loss of generality, we assume in the rest of the paper that blip-up images are given. as well as T1w images, and outputs the voxel displacement map for correcting the b0 image. The following sections detail the network architecture, loss function and preprocessing pipeline of our proposed method. Figure 1: Architecture of the proposed method. 2.1 Model Architecture Our proposed model builds on a U-Net architecture, as illustrated in Figure 1 . The encoder consists of sequential residual blocks, each using 3\times 3 convolutional kernels and skip connections to maintain gradient flow and encourage stable learning. As we progress deeper into the encoder, the number of feature maps increases from 8 to 128, with downsampling performed via max-pooling. The bottleneck features a single residual block with 128 channels, followed by a dropout layer with a rate of 0.2 to help prevent overfitting. The decoder mirrors the encoder’s structure, using transposed convolutions to upsample features and gradually reduce the number of channels from 128 back down to 8. Skip connections between corresponding encoder and decoder layers help retain spatial details. The output is generated by a 1\times 1 convolutional layer, which produces a single-channel VDM. To further mitigate overfitting, we made several architectural and regularization choices. Unlike the original U-Net [ 9 ] , which begins with 64 channels and expands up to 1024 over five downsampling layers, our model is shallower and lighter, starting with just 8 channels and growing to 128 over four levels. To further improve generalization, we introduced dropout (with a probability of 0.2) inside every residual block and after the bottleneck, which is not part of the original U-Net design. Lastly, we apply L1 regularization to penalize large weights, encouraging sparsity in the model parameters. The L1 penalty is added to the total loss with a scaling factor \lambda_{\text{reg}}=10^{-5} . 2.5D Convolutional Approach. While susceptibility distortions only occur along the phase encoding direction within individual 2D slices and are inherently one-dimensional and often localized, our model adopts a 2.5D convolutional strategy to incorporate some 3D context. Instead of using computationally expensive 3D convolutions, we process each slice together with its adjacent neighbors (one slice above and one below) as a 3-channel input. For edge slices (the first and last slices), the nearest slice is duplicated to maintain the three-slice configuration.

Read the complete text