Operational machine learning for park-scale irrigation to support urban cooling

Mesut Koçyiğit, Bahman Javadi, Russell Thomson, Sebastian Pfautsch, Oliver Obst · 2025

Read Operational machine learning for park-scale irrigation to support urban cooling by Mesut Koçyiğit, Bahman Javadi, Russell Thomson, Sebastian Pfautsch, Oliver Obst (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-11700.txt.

Introduction

Mesut Koçyiğit and co-authors run a live smart watering system for a city park that aims at cooling, not just saving water. Parks can blunt urban heat, yet watering is usually tuned for thrift. Their 2025 report describes SIMPaCT, which forecasts soil moisture zone by zone and sets overnight watering points. It draws on 202 soil sensors, fifty air sensors, and thirteen weather stations.

A simple neighbor-based forecaster runs per sensor on short rolling windows. Screen rules catch dead or stuck sensors, and a stand-in virtual sensor fills gaps. Forecast error averaged under one percent, rivaling heavier models. Operators review the settings daily before they apply. The authors share the recipe for other parks.

Catalog record

CREATORMesut Koçyiğit, Bahman Javadi, Russell Thomson, Sebastian Pfautsch, Oliver Obst
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE13 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2508-11700

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Operational machine learning for park-scale irrigation to support urban cooling Mesut Koçyiğit, Bahman Javadi, Russell Thomson, Sebastian Pfautsch, Oliver Obst Abstract Urban parks can mitigate local heat, yet irrigation control is usually tuned for water savings rather than cooling. We report on SIMPaCT (Smart Irrigation Management for Parks and Cool Towns), a park-scale deployment that links per-zone soil-moisture forecasts to overnight irrigation set-points in support of urban cooling. SIMPaCT ingests data from 202 soil-moisture sensors, 50 temperature-relative humidity (TRH) nodes, and 13 weather stations, and trains a per-sensor k-nearest neighbours (kNN) predictor on short rolling windows (200-900 h). A rule-first anomaly pipeline screens missing and stuck-at signals, with model-based checks (Isolation Forest and ARIMA). When a device fails, a mutual-information neighbourhood selects the most informative neighbour and a small multilayer perceptron supplies a “virtual sensor” until restoration. Across sensors the mean absolute error was 0.78%, comparable to more complex baselines; the upper-quartile error (P75) was lower for kNN than SARIMA (0.71% vs 0.93%). SIMPaCT runs daily and writes proposed set-points to the existing controller for operator review. This short communication reports an operational recipe for robust, cooling-oriented irrigation at city-park scale. Keywords: urban cooling; digital twin; smart irrigation; soil moisture; anomaly detection; mutual information 1 Motivation and contribution Urban green spaces are an important tool for mitigating the urban heat island effect ( Pfautsch 2022 ; Azmeer et al. 2024 ) and require careful environmental monitoring to maintain their ecological and social benefits ( Pfautsch 2022 ; Ge et al. 2025 ) . Large parks act as natural air conditioners; however, irrigation systems are often designed for water conservation rather than cooling. We address the operational gap with SIMPaCT (Smart Irrigation Management for Parks and Cool Towns), by linking short-horizon soil-moisture forecasts to overnight irrigation set-points at zone level in a live 40 ha park (Bicentennial Park, Sydney Olympic Park). Recent microclimate measurements in the same precinct found a mean park–urban air-temperature differential of about -0.4\,^{\circ}\mathrm{C} across summer 2022/23, with frequent night-time cooling exceeding 5\,^{\circ}\mathrm{C} and daytime cooling of approx. 1-2 {}^{\circ}\mathrm{C} on hot days ( Pfautsch et al. 2023 ) . Related work in brief Most ML-irrigation studies optimise water use rather than cooling ( Nosratabadi et al. 2019 ; Sharma et al. 2020 ) . Experimental field systems often couple small multi-sensor sets with classical learners such as kNN, logistic regression, SVM, naïve Bayes, and simple neural nets ( Tace et al. 2022 ; Rajan et al. 2023 ; Bhanu et al. 2020 ; Munir et al. 2021 ) . Others use SVR or clustering over humidity, temperature and soil-moisture inputs ( Ramya et al. 2020 ; Vij et al. 2020 ) . Deep sequence models have been trialled in orchards or across a few sites ( Gao et al. 2022 ; Kashyap et al. 2021 ) , and ensemble regressors on mixed soil-air variables with UV radiation have also been reported ( Singh et al. 2019 ) . These systems are typically small-scale, agriculture-focused, or lab/experimental. We report a live, park-scale pipeline that retrains daily from short windows, integrates with legacy controllers, and remains operable under device faults via an information-theoretic “virtual sensor”. Contributions. (i) A per-sensor kNN predictor trained from one week of data provides useful next-day soil-moisture forecasts. (ii) A hybrid anomaly pipeline combines simple rules with model-based checks. (iii) An information-theoretic neighbourhood selects a backup source so a small multilayer perceptron (MLP) can act as a temporary “virtual sensor” when devices fail. Forecasts of per-zone proposals are visualised and can be accepted or overridden by operators. This short communication focuses on the operational ML layer: forecasting, anomaly screening, and the information-theoretic backup. System architecture, dashboards, and the broader digital-twin workflow are documented in the companion paper ( Cressall et al. 2023 ) . 2 System in brief SIMPaCT operates 202 soil-moisture sensors, 50 temperature-relative humidity (TRH) sensors and 13 weather stations that transmit data via LoRaWAN (Long Range Wide Area Network)/4G. Weather stations were mounted on lamp posts at \sim 3 m with short outriggers, sampled at 15 min cadence, and forwarded via 4G to the Fieldmouse platform; the deployment protocol and siting are detailed in ( Pfautsch et al. 2023 ) . The SIMPaCT platform, built on Senaps ( Mac Coombea et al. 2017 ) , ingests sensor streams and Bureau of Meteorology forecasts, maintains a per-zone digital twin and produces forecast soil moisture and proposed overnight runtimes. Proposals are posted to the existing irrigation network controller that operates the about 200 controllable sprinkler stations; accepted runtimes are logged. Figure 1 shows the station layout and network. A companion paper documents the digital-twin architecture, dashboards and end-to-end workflow in more detail ( Cressall et al. 2023 ) . Figure 1 : Park context: sensor placement (left, orange); part of the irrigation network (right, blue lines). Operational constraints and integration Irrigation is constrained by public access, pressure management and event blackouts. Only one main line runs at a time, watering in short overnight windows. SIMPaCT writes per-zone set-points to the legacy irrigation network controller and logs executed runtimes. Catch-can field tests provided runtime-to-application-rate factors so scheduled minutes can be compared with forecast precipitation on a common mm h -1 scale. Virtual sensor and backup predictor Sensor faults are inevitable in long-running deployments ( Jurdak et al. 2011 ) . When a sensor is flagged faulty by the rules or model checks, SIMPaCT activates a temporary “virtual sensor”. We precompute an information-theoretic neighbourhood by estimating pairwise mutual information (MI) between the continuous sensor time series using the Kraskov–Stögbauer–Grassberger k -NN estimator as implemented in JIDT ( Kraskov et al. 2004 ; Lizier 2014 ) . We use the standard definition of mutual information (natural logs): I(X;Y)\;=\;\mathbb{E}_{p_{XY}}\!\left[\log\frac{p_{XY}(x,y)}{p_{X}(x)\,p_{Y}(y)}\right]. (1) This yields a connectivity matrix; for each target we retain the single most-informative neighbour (top-1 by I , Eq. 1 ). On activation, a small multilayer perceptron (one hidden layer, 10 ReLU units) is trained on the recent history (200–900 h) to map the neighbour’s series to the target. The virtual sensor outputs values at the same cadence as the failed device and is refreshed daily until the physical sensor returns. This keeps the architecture simple, avoids chaining many dependencies, and limits drift, while providing continuity for forecasting and set-point generation. The MI matrix is computed offline and refreshed infrequently; at runtime this paper’s contribution is the MI-selected neighbour plus a small MLP backup predictor that maps the neighbour’s series to the target, while visualisation and operator workflow are handled by the platform described in ( Cressall et al. 2023 ) . For Fig. 2 and Fig. 3 we used a 13-sensor subset resampled to hourly cadence from device readings between 2022-11-15 and 2023-01-17 ( Koçyiğit et al. 2025 ) ; in production the MI matrix covers the full network. Neighbour choice We retain only the most informative neighbour per target (top-1 by MI). This keeps the backup graph sparse, limits cascading dependencies if another device fails, and allows a small MLP to train quickly on the fly. In practice, a monthly MI matrix recomputation (or after topology changes) was sufficient because inter-sensor relationships were stable. Rule-based anomaly checks We apply simple rules before model-based detectors: - Missingness

Read the complete text