QUEST-DMC Collaboration, E. Leason, L. V. Levitin, S. Autti, E. Bloomfield, A. Casey, N. Darvishi, N. Eng, P. Franchini, R. P. Haley, P. J. Heikkinen, A. Jennings, A. Kemp, J. March-Russell, A. Mayer, J. Monroe, D. Münstermann, M. T. Noble, J. R. Prance, X. Rojas, T. Salmon, J. Saunders, J. Smirnov, · 2025

Read Development of superfluid helium-3 bolometry using nanowire resonators with SQUID readout for the QUEST-DMC experiment by QUEST-DMC Collaboration, E. Leason, L. V. Levitin, S. Autti, E. Bloomfield, A. Casey, N. Darvishi, N. Eng, P. Franchini, R. P. Haley, P. J. Heikkinen, A. Jennings, A. Kemp, J. March-Russell, A. Mayer, J. Monroe, D. Münstermann, M. T. Noble, J. R. Prance, X. Rojas, T. Salmon, J. Saunders, J. Smirnov, (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-10602.txt.

Introduction

The QUEST-DMC team describes detectors made of superfluid helium-3 that could sense very light dark matter particles. At ultra-low temperatures the fluid takes almost no heat to warm, so even a tiny particle hit could register. Their 2025 paper builds the sensing around vibrating wires, some thinner than a hair, read out by sensitive superconducting amplifiers.

The detector holds two wires, which lets the team inject known heat pulses for calibration and cross-check real events. Matching signals on both wires confirm a shared response. A proof-of-concept run shows several wires can share one readout line by frequency. The authors present the work as groundwork for a future low-threshold dark matter search.

Catalog record

CREATORQUEST-DMC Collaboration, E. Leason, L. V. Levitin, S. Autti, E. Bloomfield, A. Casey, N. Darvishi, N. Eng, P. Franchini, R. P. Haley, P. J. Heikkinen, A. Jennings, A. Kemp, J. March-Russell, A. Mayer, J. Monroe, D. Münstermann, M. T. Noble, J. R. Prance, X. Rojas, T. Salmon, J. Saunders, J. Smirnov,
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE28 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2508-10602

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

Development of superfluid helium-3 bolometry using nanowire resonators with SQUID readout for the QUEST-DMC experiment QUEST-DMC Collaboration, E. Leason, L. V. Levitin, S. Autti, E. Bloomfield, A. Casey, N. Darvishi, N. Eng, P. Franchini, R. P. Haley, P. J. Heikkinen, A. Jennings, A. Kemp, J. March-Russell, A. Mayer, J. Monroe, D. Münstermann, M. T. Noble, J. R. Prance, X. Rojas, T. Salmon, J. Saunders, J. Smirnov, R. Smith, M. D. Thompson, A. Thomson, A. Ting, V. Tsepelin, S. M. West, L. Whitehead, D. E. Zmeev Abstract Superfluid helium-3 bolometers can be utilised for dark matter direct detection searches. The extremely low heat capacity of the B phase of the superfluid helium-3 at ultra-low temperatures offers the potential to reach world leading sensitivity to spin dependent interactions of dark matter in the sub-GeV/c 2 mass range. Here, we describe the development of bolometry using both micron scale and sub-micron diameter vibrating wire resonators, with a SQUID amplifier-based readout scheme. Characterisation of the resonators and bolometer measurements are shown, including the use of non-linear operation and the corresponding corrections. The bolometer contains two vibrating wire resonators, enabling heat injection calibration and simultaneous bolometer tracking measurements. Coincident events measured on both vibrating wire resonators verify their response. We also demonstrate proof of concept frequency multiplexed readout. Development of these measurement techniques lays the foundations for the use of superfluid helium-3 bolometers, instrumented with vibrating nano-mechanical resonators, for future low threshold dark matter searches. 1 Introduction The QUEST-DMC programme uses a superfluid helium-3 bolometer for dark matter direct detection searches. This detection scheme, described in Ref. QUESTSens24 , is suited to sub-GeV/c 2 dark matter masses and has the potential to reach world leading sensitivity to dark matter interactions in this mass range QUESTESE ; QUESTEFT . The bolometer exploits the extremely low heat capacity of the B phase of the superfluid helium-3 at ultra-low temperatures below 0.4 mK, where most quasiparticles are bound into Cooper pairs. Vibrating wire resonators are utilised primarily to measure the strongly temperature-dependent quasiparticle density and secondly as heaters for calibration. This technique was originally developed by the ULTIMA collaboration Winkelmann2007 . In QUEST-DMC we expect several orders of magnitude improvement in sensitivity as a result of two key developments: novel vibrating wire resonators with sub-micron diameter and Superconducting QUantum Interference Device (SQUID) readout. We demonstrate the reliable SQUID readout of the bolometer with resonators in the non-linear regime close to the critical velocity. We show the use of a second vibrating wire as a heater, with much lower power heat injection than previously. Having two vibrating wires also allows for simultaneous tracking and coincident bolometer events are measured on both, verifying the response of the wires. The energy calibration with low-energy gamma rays and a study of noise performance of the bolometer will be subject of a separate report. Our circuit contains no additional cryogenic components apart from the vibrating wire and integrated SQUID current sensor Drung2007 , in comparison to more complex schemes developed previously BradleySQUID2000 ; MartikainenSQUIDVWR01 . This simplicity lends itself to scaling up by running an array of bolometers in parallel. Furthermore we demonstrate multiplexing by reading out two resonances with one SQUID simultaneously. Figure 1: Schematic drawing of the bolometer cell mounted on a nuclear demagnetisation refrigerator. The cell includes the silver sinter heat exchanger, reservoir of superfluid 3 He (2 cm 3 ) and bolometer opened to the reservoir via a small orifice. The base of the cell is in good thermal contact with the copper demagnetisation stage, precooled by an Oxford Instruments Kelvinox 400 dilution refrigerator (DR). The bolometer is equipped with thermometer/heater vibrating wires, connected to SQUID sensors with integrated drive transformers, mounted at the 1 K pot plate of DR. The magnetic fields for the operation of vibrating wires is provided by a small superconducting magnet, separate from the large demagnetisation magnet situated in the 4 He bath of the cryostat. The bolometer and cell walls include gamma ray transparent windows for energy calibration using a 55 Fe source located outside the cell. 2 Experimental setup The experimental assembly is illustrated in Fig. 1 . A wet commercial dilution refrigerator was extended with a large copper nuclear demagnetisation stage. The bolometer is situated inside a mostly metallic cell filled with helium-3, mounted on top of the demagnetisation stage. Helium-3 in the main reservoir of roughly 2 cm 3 is cooled by a silver sinter heat exchanger of estimated surface area 20 m 2 . The superfluid helium-3 bolometer is a 7\times 5\times 5 mm cuboid open to the main reservoir via a 0.3 mm diameter orifice, which provides the cooling of the superfluid helium-3 target. A well-defined bolometer volume is essential to establishing a reliable energy calibration. To this end the bolometer cavity was machined out of a solid copper puck, with the upper and lower walls constructed from flat copper foils. This essentially metallic construction ensures no heating of the bolometer due to heat release in disordered materials such as paper and epoxies, traditionally used in construction of helium-3 bolometers. Minimal amounts of Stycast 1266 and Araldite epoxies were used to seal the joints between the puck and foils and for the vibrating wire feedthroughs. The main materials used have been screened in the Boulby Underground Germanium Screening facility to ensure acceptable levels of radiopurity QUESTBg24 . Figure 2: A 400 nm nanowire photographed through an optical microscope. Araldite epoxy beads stabilises the extruded superconducting cable at both ends of the wire. In the section between the beads all filaments but one were removed after etching away the copper matrix. The bolometer contains NbTi vibrating wires of two diameters: the 4500 nm wires were obtained commercially as filaments of a multifilament superconducting cable in copper matrix; the 400 nm nanowires, Fig. 2 , were produced by drawing such cable through a series of dies, similar to the procedure described in Ref. QUESTlongwires . Sections of complete cable at both ends of the vibrating wires served as ‘legs’ and were mounted in the bolometer wall using Araldite epoxy. The vibrating wires are connected to SQUID current sensors, installed on the 1 K pot plate of the dilution refrigerator. Transformers integrated into the SQUIDs were used to drive the vibrating wires ( Drung2007 ) . The electrical connections to the cell are minimal: a single NbTi twisted pair shielded inside a Nb tube per vibrating wire. This electrical circuit and its performance are discussed in Sec. 3 below. The magnetic field for electrical excitation and readout of the mechanical resonators is provided by a small superconducting magnet suspended off the mixing chamber plate of the dilution refrigerator. The nuclear stage is also rigidly attached to this plate, minimising relative motion of the bolometer and the magnet. In the earlier Lancaster-style design QUESTSens24 the bolometer is embedded inside an assembly of sintered nuclear stages, to reach exceptionally low helium temperatures. In contrast, here we can alter the sample field independent of the demag field, in order to investigate the performance of the SQUID readout. In addition to direct heat injection, our approach to energy calibration will use low energy deposition from a well-characterised 55 Fe source. The standard packaging of commercial

Read the complete text