Coaxial Dipole Array with Switching Transmit Sensitivities for ultrahigh field MRI
Dario Bosch, Georgiy A. Solomakha, Felix Glang, Martin Freudensprung, Nikolai I. Avdievich, Klaus Scheffler · 2025
Read Coaxial Dipole Array with Switching Transmit Sensitivities for ultrahigh field MRI by Dario Bosch, Georgiy A. Solomakha, Felix Glang, Martin Freudensprung, Nikolai I. Avdievich, Klaus Scheffler (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-10205.txt.
Introduction
Dario Bosch, Georgiy Solomakha, Felix Glang, Martin Freudensprung, Nikolai Avdievich, and Klaus Scheffler wrote this paper in two thousand twenty-five. It builds an MRI antenna array whose transmit pattern can switch mid-pulse, to even out the flip angle at ultrahigh field.
Eight coaxial dipoles carry PIN diodes and inductors that reshape the current along each stick. That shifts the field between the top and base of the brain by a fair step in models. Fired fast during a pulse, the switch can more than double flip angle evenness in one scheme. A built array shows the effect too, though weaker than the models. The trick adds a new knob without more costly transmit channels.
Catalog record
| CREATOR | Dario Bosch, Georgiy A. Solomakha, Felix Glang, Martin Freudensprung, Nikolai I. Avdievich, Klaus Scheffler |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-10205
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Coaxial Dipole Array with Switching Transmit Sensitivities for ultrahigh field MRI Dario Bosch, Georgiy A. Solomakha, Felix Glang, Martin Freudensprung, Nikolai I. Avdievich, Klaus Scheffler Abstract Purpose: To investigate dipole antennas with electronically switchable transmit field patterns to improve flip angle homogeneity in ultra-high field MRI Methods: An array of eight coaxial dipoles with electronically switchable B 1 + B_{1}^{\!+} field profiles was constructed. Alteration of the field profiles was accomplished by modulating the currents along the dipoles using a combination of PIN diodes and lumped inductances. The behavior of these reconfigurable elements was studied in numerical electromagnetic simulations and 9.4T MRI measurements, investigating rapid switching of transmit sensitivities during excitation pulses in both single-channel and pTx mode operation. Results: For the simulated dipole elements, modulating the current densities along the dipole’s axis causes a ∼ \sim 30% change of the B 1 + B_{1}^{\!+} field between superior and inferior regions of the brain. When rapidly switched during excitation pulses, this degree of freedom can improve flip angle homogeneity, e.g. by a factor of ∼ \sim 2.2 for a two kT points pTx pulse. For the constructed prototype array, the switching effect was observable but weaker, causing ∼ \sim 10% superior-inferior B 1 + B_{1}^{\!+} variation. Conclusion: The proposed coaxial dipole array with switchable transmit sensitivities offers a novel degree of freedom for designing excitation pulses. The approach has the potential to improve flip angle homogeneity without necessitating an expensive increase in the number of independent transmit channels. keywords RF-shimming, pTx, kT-points, dipoles, arrays † † equal-contributors: These authors contributed equally to this work. † † equal-contributors: These authors contributed equally to this work. 1 Introduction In ultra-high field MRI (UHF MRI, \geq 7 Tesla), the transmit (Tx) radio-frequency (RF) field (usually referred to as B_{1}^{\!+} field) is inherently inhomogeneous due to its short wavelength compared to the sample size ladd2018pros ; cao2015numerical . To compensate these inhomogeneities, state-of-the-art UHF MRI systems are often equipped with parallel transmit (pTx) systems deniz2019parallel . These systems allow driving a set of Tx RF-elements independently with usually 8 or 16 independent channels ladd2018pros , thus giving control over the interference pattern of the RF field generated by the Tx elements by adapting the magnitude and phase of the waveform delivered to each individual element. This is generally referred to as ”RF shimming” mao2006exploring . Having individual RF amplifiers for each Tx channel allows modifying the RF magnitude and phase dynamically, as opposed to building a dedicated power splitter for an array of Tx elements that could provide only one fixed phase and amplitude excitation for the array. This is employed, for example, in slice-by-slice RF shimming, or for optimized composite pulses such as spokes pulses or kT-points cloos2012kt , where an optimized RF shim is computed for each individual sub-pulse. The number of degrees of freedom in this process can be increased by increasing the number of Tx channels of the MRI system. However, due to the high technical complexity and cost, very few MRI systems are equipped with more than 8 Tx channels. If an RF-coil with 16-channels is available, 8 elements can be driven by a power splitter symmetrically or asymmetrically yan2018ratio-adjustable ; sappo2024optimizing , so that 2 or more elements are driven by each single Tx channel. This does not increase the number of degrees of freedom, since the power splitters have a fixed behavior defined by their hardware. It does, however, allow for improved Tx array designs that offer, for example, larger coverage. Another way of driving a large number of Tx elements is Tx multiplexing avdievich_transceiver-phased_2011 . Here, multiple Tx elements are connected to a single Tx channel by an electronically controlled switch that allows routing the RF power to a specific element at a time and change that setting within a very short time, i.e. less than 1 µs. This method, however, introduces additional complexity since not only a larger number of elements need to be built, but also switches that can handle the high RF power and still switch fast and reliably. In the past years, multiple projects used receive (Rx) loop glang2022accelerated and dipole nikulin2023reconfigurable ; solomakha2024dynamic elements with switchable sensitivities to boost parallel imaging performance pruessmann1999sense and reduce the geometrical factor, which describes the noise amplification due to parallel imaging reconstruction. Additional electronic components within the Rx element allow changing the spatial distribution of its sensitivity. The sensitivities were switched back and forth during the signal acquisition phase of an MRI pulse sequence, multiplexing the two states of the Rx elements. The two Rx sensitivity states were then treated like different coil images in SENSE pruessmann1999sense parallel imaging reconstruction. Inspired by this previous work, we adapted the approach of RF elements with switchable sensitivities to transmit elements. A coaxial dipole element was previously proposed by van Leeuven et al. van2022coax and evaluated as array element for 9.4T head imaging by Solomakha et al. solomakha2024evaluation . Such an array element has a current distribution that is symmetrical around its feed point, causing the generated B_{1}^{\!+} field to have the same symmetry. To control the current distribution, two lumped inductors can be placed at the end of the dipole, between the shield and the central conductor of the coaxial cable. If one end of the dipole is made capacitive (or open circuit) instead of inductive, the current distribution is skewed towards that end, causing the B_{1}^{\!+} field to be skewed accordingly. The goal is then to use these distinct time-varying transmit sensitivities as additional degree of freedom for RF pulse design. In this work, we investigate such reconfigurable transmit dipoles based on numerical simulations, demonstrating the potential of this approach to improve flip angle homogeneity. For that, the transmit sensitivities are rapidly switched in between the sub-pulses of both CP mode and optimized kT points excitation pulses. In addition, we perform an experimental proof-of-concept with a self-built prototype 8-element coil array applied for human brain imaging. Preliminary simulation results of this approach have been presented on previous conferences bosch_txloom_2023 ; bosch_txloom_2024 . 2 Methods 2.1 Design and Numerical Simulations of the Element Figure 1: Illustration of functioning principle of the switchable dipole element. (A) View of the numerical model of a single switchable coaxial dipole antenna. (B) Switchable unit circuit for high power operation. (C) Numerically simulated B_{1}^{\!+} field for “down” and “up” configuration of switchable coaxial dipole antenna. (D) Ratio between down and up field configuration. First, single dipoles were simulated to demonstrate how the B_{1}^{\!+} field pattern changes with changing load impedance at the dipole’s end. This was done in CST Studio 2021 (Dassault Systèmes, France), using the finite-element method in the frequency domain. A single coaxial dipole was constructed from coaxial cable with a center conductor diameter of 1 mm and a shield diameter of 3.4 mm, similar to previous publications solomakha2024dynamic ; solomakha2024evaluation . Both central conductor and shield were made from copper. Inner and outer coaxial cable diameters were doubled compared to the real coaxial cable to increase the accuracy of the numerical simulation. The total length of the coaxial dipole was 17 cm with slots located at 20 mm distance from the dipole’s ends. The dipole element was loaded to