AST-n: A Fast Sampling Approach for Low-Dose CT Reconstruction using Diffusion Models
Tomás de la Sotta, José Manuel Saavedra, Héctor Henríquez, Violeta Chang, Aline Xavier · 2025
Read AST-n: A Fast Sampling Approach for Low-Dose CT Reconstruction using Diffusion Models by Tomás de la Sotta, José Manuel Saavedra, Héctor Henríquez, Violeta Chang, Aline Xavier (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-09943.txt.
Introduction
Tomas de la Sotta and co-authors present a 2025 method to speed up computer repair of low-dose CT scans. Low-dose scans cut radiation but add noise that can shake a doctor's trust in the image. A class of AI models can clean such scans by slow, step-by-step refinement. Their method starts that process part-way, at a middle noise level. It uses stronger math solvers so fewer steps are needed. Tests used a public challenge set of head, belly, and chest scans.
With just twenty-five steps, the guided version matched the quality of slow standard runs. It cut the time per slice from about sixteen seconds to under one second. A version without guidance lost much quality, which shows guidance matters. An extra inversion trick gained little and doubled the time. The authors say fast cleaning like this could fit real clinic flow.
Catalog record
| CREATOR | Tomás de la Sotta, José Manuel Saavedra, Héctor Henríquez, Violeta Chang, Aline Xavier |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 20 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-09943
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
AST-n: A Fast Sampling Approach for Low-Dose CT Reconstruction using Diffusion Models Tomás de la Sotta, José Manuel Saavedra, Héctor Henríquez, Violeta Chang, Aline Xavier Abstract Low-dose CT (LDCT) protocols reduce radiation exposure but increase image noise, compromising diagnostic confidence. Diffusion-based generative models have shown promise for LDCT denoising by learning image priors and performing iterative refinement. In this work, we introduce AST-n, an accelerated inference framework that initiates reverse diffusion from intermediate noise levels, and integrate high-order ODE solvers within conditioned models to further reduce sampling steps. We evaluate two acceleration paradigms—AST-n sampling and standard scheduling with high-order solvers—on the Low Dose CT Grand Challenge dataset, covering head, abdominal, and chest scans at 10–25 % of standard dose. Conditioned models using only 25 steps (AST-25) achieve peak signal-to-noise ratio (PSNR) above 38 dB and structural similarity index (SSIM) above 0.95, closely matching standard baselines while cutting inference time from ∼ \sim 16 s to under 1 s per slice. Unconditional sampling suffers substantial quality loss, underscoring the necessity of conditioning. We also assess DDIM inversion, which yields marginal PSNR gains at the cost of doubling inference time, limiting its clinical practicality. Our results demonstrate that AST-n with high-order samplers enables rapid LDCT reconstruction without significant loss of image fidelity, advancing the feasibility of diffusion-based methods in clinical workflows. 1 Introduction Radiological imaging has become one of the most essential tools for diagnosing pathologies, monitoring disease progression, and guiding therapeutic interventions. Among these, ionizing radiation-based diagnostic modalities constitute one of the main sources of radiation exposure in the general population, accounting for approximately 50% of total exposure to ionizing radiation, including both natural and anthropogenic sources [ 8 ] . In recent decades, the number of radiological examinations has increased considerably, contributing to faster and more accurate diagnoses and reducing the reliance on invasive, high-risk procedures. Computed tomography (CT) has emerged as one of the most widely used modalities due to its excellent diagnostic performance and rapid acquisition. However, it is also considered the single largest contributor to medical radiation exposure [ 2 ] . For example, while a chest X-ray delivers an effective dose of approximately 0.1 mSv—roughly equivalent to 10 days of natural background exposure—a CT scan typically delivers between 1.5 and 15.4 mSv, depending on the anatomical region, protocol complexity, and the number of acquisition phases [ 1 ] . In specific cases, doses can reach up to 37 mSv. The biological effects of ionizing radiation are cumulative and may include damage to genetic material, increasing the risk of radiation-induced neoplasms. Although estimating this risk is complex, Brenner et al. [ 2 ] suggest that between 1.5% and 2.0% of neoplasms may be attributable to current CT usage, with risks being notably higher for younger individuals. Consequently, minimizing dose exposure while maintaining diagnostic quality remains a pressing challenge, particularly in pediatric and young adult populations. To address this, low-dose CT (LDCT) protocols attempt to reduce radiation exposure by decreasing X-ray intensity. However, this reduction often results in significant image noise, adversely affecting diagnostic reliability. Although traditional denoising and iterative reconstruction methods can partially mitigate these effects, their performance tends to deteriorate under extreme low-dose conditions. In recent years, deep learning has emerged as a powerful tool for medical image enhancement, including LDCT reconstruction. Multiple neural-network-based approaches have demonstrated strong results [ 3 , 13 , 14 ] , particularly those employing diffusion-based generative models, which leverage learned image priors and iterative refinement processes [ 7 , 5 , 4 ] . Despite the rapid progress in this field, several key limitations remain unaddressed. Although diffusion-based models have achieved excellent reconstruction quality, they often require long inference times, which are frequently incompatible with the time-sensitive nature of CT examinations. In clinical settings, CT is valued precisely for its speed, and introducing reconstruction latencies of several seconds per volume can hinder its practical deployment. Furthermore, many existing models are optimized to predict residual noise rather than directly reconstruct the image content, a strategy that has been shown to be suboptimal in restoration tasks [ 11 ] . In this study, we explore the use of existing diffusion-based generative models for low-dose CT reconstruction by incorporating two complementary strategies to reduce inference time and enhance clinical applicability. First, we implement a low-dose conditioning scheme based on slice-level input concatenation, which provides anatomical context to guide the generative process. Second, we adopt AST-n, a timestep reduction strategy that initiates the reverse diffusion from intermediate noise levels instead of pure Gaussian noise, leading to a significant reduction in inference time. Our main contribution lies in the systematic integration of AST-n sampling into an existing conditioned generative diffusion framework for LDCT reconstruction—without modifying the model architecture or requiring additional training. This enables previously trained models to be retrofitted with accelerated inference capabilities at minimal computational cost, enhancing their usability with almost no degradation in the model’s performance. By substantially reducing the number of sampling steps, our approach lowers inference time by an order of magnitude, moving diffusion-based reconstruction closer to real-time applicability. Clinically, this not only increases the feasibility of high-quality LDCT imaging in time-critical scenarios—ultimately contributing to safer diagnostic practices by making dose-reduction strategies more accessible in healthcare—but also enables faster image availability and improved workflow efficiency, especially in contexts where diagnostic speed is essential. For clarity and ease of reading, the remainder of this paper is structured as follows. Section 2 reviews related work on LDCT reconstruction using generative models. Section 3 presents our proposed approach, including dataset details, model architecture, and acceleration strategies. Section 4 reports and discusses the experimental results. Finally, Section 5 concludes the paper and outlines directions for future research. 2 Related Work The generation of high-quality images from low-dose CT (LDCT) acquisitions has become a prominent challenge in radiological imaging. While reduced radiation protocols are crucial for minimizing patient risk, particularly in repeated scans and vulnerable populations, they significantly degrade image quality due to low signal-to-noise ratios. To address this, numerous deep learning approaches have been proposed in recent years, aiming to reconstruct full-dose-equivalent images from noisy LDCT inputs. One of the earliest efforts in this direction was proposed by Chen et al. [ 3 ] , who used a convolutional neural network to directly map low-dose images to their full-dose counterparts. This line of work laid the foundation for supervised denoising in CT using image-to-image learning. More recent approaches have explored diffusion-based generative models, leveraging their strong prior modeling capabilities and iterative refinement properties. Xia et al. [ 13 ] applied Denoising Diffusion Probabilistic Models (DDPMs) to LDCT reconstruction and introduced an acceleration scheme based on modeling the reverse process with ordinary differential equations (ODEs), following the formulation of Lu et al. [ 9 ] . Their model, conditioned on the low-dose image, achieved substantial improvements in reconstruction quality while reducing inference time by up to 20×. In a complementary approach, Huang et al. [ 7 ] addressed the problem in the sinogram domain. They trained a diffusion model to infer the ideal sinogram from low-dose projections, using low-rank Hankel priors to regularize the reconstruction. This strategy allowed them to operate in the raw projection space before applying traditional image reconstruction techniques. Gao and Shan