Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments Journal: Nucl. Instrum. Methods Phys. Res. A
T. J. Roosendaal, C. T. Overman, G. S. Ortega, T. D. Schlieder, N. D. Rocco, L. K. S. Horkley, K. P. Hobbs, K. Harouaka, J. L. Orrell, P. Acharya, A. Amy, E. Angelico, A. Anker, I. J. Arnquist, A. Atencio, J. Bane, V. Belov, E. P. Bernard, T. Bhatta, A. Bolotnikov, J. Breslin, P. A. Breur, J. P. Bro · 2025
Read Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments Journal: Nucl. Instrum. Methods Phys. Res. A by T. J. Roosendaal, C. T. Overman, G. S. Ortega, T. D. Schlieder, N. D. Rocco, L. K. S. Horkley, K. P. Hobbs, K. Harouaka, J. L. Orrell, P. Acharya, A. Amy, E. Angelico, A. Anker, I. J. Arnquist, A. Atencio, J. Bane, V. Belov, E. P. Bernard, T. Bhatta, A. Bolotnikov, J. Breslin, P. A. Breur, J. P. Bro (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-08230.txt.
Introduction
Roosendaal and co-authors wrote a paper from 2025 on ultra-pure nickel as a building material for the most sensitive physics detectors. Rare-event hunts, such as those for dark matter, need frames that are strong yet nearly free of radioactive traces. Even faint traces can swamp the rare signals they seek. The team tested nickel grown as a vapor on metal sheets, a method that can leave the metal very clean.
The grown nickel proved far stronger than standard nickel in pull tests. Welding and heat, though, cut that strength back to standard levels. Pores in the welds likely played a part in the loss. Fine chemical assays measured the traces of two key radioactive elements in the bulk metal. The work weighs the gain in purity against the loss in strength after joining. It gives detector builders a firmer base for picking frame materials.
Catalog record
| CREATOR | T. J. Roosendaal, C. T. Overman, G. S. Ortega, T. D. Schlieder, N. D. Rocco, L. K. S. Horkley, K. P. Hobbs, K. Harouaka, J. L. Orrell, P. Acharya, A. Amy, E. Angelico, A. Anker, I. J. Arnquist, A. Atencio, J. Bane, V. Belov, E. P. Bernard, T. Bhatta, A. Bolotnikov, J. Breslin, P. A. Breur, J. P. Bro |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 47 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-08230
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments Journal: Nucl. Instrum. Methods Phys. Res. A T. J. Roosendaal, C. T. Overman, G. S. Ortega, T. D. Schlieder, N. D. Rocco, L. K. S. Horkley, K. P. Hobbs, K. Harouaka, J. L. Orrell, P. Acharya, A. Amy, E. Angelico, A. Anker, I. J. Arnquist, A. Atencio, J. Bane, V. Belov, E. P. Bernard, T. Bhatta, A. Bolotnikov, J. Breslin, P. A. Breur, J. P. Brodsky, E. Brown, T. Brunner, B. Burnell, E. Caden, L. Q. Cao, D. Cesmecioglu, S. A. Charlebois, D. Chernyak, M. Chiu, T. Daniels, L. Darroch, R. DeVoe, M. L. di Vacri, M. J. Dolinski, B. Eckert, M. Elbeltagi, A. Emara, W. Fairbank, B. T. Foust, D. Gallacher, N. Gallice, W. Gillis, A. Gorham, G. Gratta, C. A. Hardy, S. C. Hedges, M. Heffner, E. Hein, J. D. Holt, A. Iverson, A. Karelin, I. V. Kotov, A. Kuchenkov, A. Larson, M. B. Latif, S. Lavoie, K. G. Leach, B. G. Lenardo, D. S. Leonard, K. K. H. Leung, H. Lewis, X. Li, Z. Li, C. Licciardi, R. Lindsay, R. MacLellan, S. Majidi, C. Malbrunot, M. Marquis, J. Masbou, M. Medina-Peregrina, S. Mngonyama, B. Mong, D. C. Moore, X. E. Ngwadla, K. Ni, A. Nolan, S. C. Nowicki, J. C. Nzobadila Ondze, A. Odian, L. Pagani, H. Peltz Smalley, A. Pena-Perez, A. Piepke, A. Pocar, S. Prentice, V. Radeka, R. Rai, H. Rasiwala, D. Ray, S. Rescia, G. Richardson, V. Riot, R. Ross, P. C. Rowson, R. Saldanha, S. Sangiorgio, S. Sekula, T. Shetty, L. Si, J. Soderstrom, F. Spadoni, V. Stekhanov, X. L. Sun, S. Thibado, T. Totev, S. Triambak, R. H. M. Tsang, O. A. Tyuka, E. van Bruggen, M. Vidal, M. Walent, Y. G. Wang, Q. D. Wang, M. P. Watts, M. Wehrfritz, L. J. Wen, S. Wilde, M. Worcester, X. M. Wu, H. Xu, H. B. Yang, L. Yang, O. Zeldovich Abstract The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ∼ \sim 600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232 Th, 238 U, and nat {}^{\text{nat}} K at the levels of ∼ \sim 70 ppq, ≲ \lesssim 100 ppq, and ∼ \sim 900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ∼ \sim 10 μ \mu m beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments. 1 Introduction nEXO is a concept for a tonne-scale neutrinoless double beta decay experiment consisting of 5 tonnes of liquid xenon, enriched to 90% 136 Xe, and operated as a time projection chamber for detection of radiation-induced ionization events [ 1 ] . Observation of neutrinoless double beta decay would imply neutrinos are Majorana fermions [ 2 ] , which would be a unique characteristic among the particles within the Standard Model. This observation would also demonstrate the existence of lepton number violation and have potential ramifications for understanding the matter/antimatter asymmetry of the universe [ 3 ] . A critical design characteristic for nEXO is the use of construction materials that are extremely low in radioactive contaminants which may generate backgrounds to the observation of the rare double beta decay events of 136 Xe [ 4 ] . In this report, the investigation of ultra-pure chemical vapor deposition (CVD) nickel (Ni) is presented. In particular, the nEXO experiment initially pursued use of CVD Ni for the construction of the inner and outer vessels of the cryostat used to maintain the detector volume at liquid xenon temperatures. The spherical inner and outer vessels have nominal diameters of 3.4 m and 4.5 m, respectively. The purpose and size of these components implies the need for both strength and low levels of radioactive contaminants of the CVD Ni. To the authors’ best knowledge, the first (and last to date 1 1 1 The SNO NCDs were repurposed for the HALO experiment [ 5 ] . ) use of ultra-pure CVD Ni for low-radioactive background rare-event searches in nuclear and particle physics, was in the construction of the Sudbury Neutrino Observatory’s (SNO’s) [ 6 , 7 ] Neutral Current Detectors (NCDs) [ 8 , 9 ] . The SNO NCDs were cylindrical 3 He proportional counters with 5.08 cm outer diameter and lengths ranging from 200–300 cm. A key factor in the choice of CVD Ni was the low concentrations of radioactive 232 Th- and 238 U-decay chain nuclides which could contribute to a background event rate in the SNO experiment. However, as noted by the SNO Collaboration [ 8 ] , the CVD Ni tubes were produced on Al mandrels, and that Al (as well as trace materials within the Al) can be incorporated into the surface of the CVD Ni. Thus, the SNO Collaboration used post-production electropolishing and etching as a surface cleaning step. The CVD Ni was produced by the Canadian company Mirotech, Inc. and later Chemical Vapour Deposition Systems, Inc., which acquired Mirotech [ 9 ] . Further details of the physical properties and radioactivity concentrations of the SNO NCD CVD Ni are referenced later in this report for comparison purposes. This report first briefly describes the production of samples from the CVD Ni obtained by the nEXO Collaboration for analysis (Sec. 2 ). The contents of this report focus on key measured physical properties (Sec. 3 ) and trace radioactive contamination levels (Sec. 4 ). The physical property analyses focus on tensile strength before and after both welding and heat treatment, where comparison is provided against commercial off the shelf (COTS) Ni samples. The trace radioactive contamination analysis focuses on determining the bulk and surface concentrations of 232 Th, 238 U, and, for the first time reported, 40 K. To place this report’s results in context, at the end of both the physical properties and trace radioactive contamination sections (Sec. 3 and Sec. 4 , respectively), comparisons to the information available from the SNO Collaboration’s experience with CVD Ni are presented. A brief conclusion (Sec. 5 ) summarizes the results and recommendations for further development of CVD Ni as a generic ultra-pure construction material for use in future nuclear and particle physics