Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment
2025
Read Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-07846.txt.
Introduction
A large T2K team presents a new time calibration method for multi-channel particle detectors, in a paper from two thousand twenty-five. Kit like that in the T2K neutrino experiment reads out through many channels. Each channel has its own electronics. Small gaps in timing from one channel to the next cap how sharp the time readings can be.
The new method works step by step and rests on Markov chain ideas. It fixes tiny gaps in sync across channels, and it does so with little waste. The team shows it at work on two T2K detectors, SuperFGD and the time-of-flight system. Good timing counts for a lot here. Such experiments rebuild events from the exact times at which hits arrive. A method that squeezes out offsets helps the whole detector do its best work. Staff from many sites took part in the work.
Catalog record
| YEAR | 2025 |
|---|---|
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 57 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-07846
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment Abstract Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability. 1 1 footnotetext: Corresponding author(s). 1 Introduction Large-scale ionisation detectors typically employ a substantial number of readout channels organised into multiple independent electronics units, synchronised through use of a common primary clock signal. Contemporary examples can be found in scintillator detectors used as active targets for neutrino experiments, where light is conveyed to the optical sensor via optical fibres [ 1 , 2 , 3 , 4 , 5 , 6 ] . In these systems, secondary clock phase-locking mis-synchronisation, imperfect cable length and trace matching, and comparator switching delays can result in fixed offsets in the hit times recorded by different channels that can negatively affect the resultant time resolution of the detector. Great progress is being made to reduce the time resolution of individual channels, both in terms of enhancing the readout electronics performance, and in development of fast scintillating materials [ 7 , 8 , 9 ] . As the time resolution of individual readout channels improve, it becomes imperative to address the mis-synchronisation between multiple channels, in order to prevent that becoming the limiting factor in a detector’s resultant time resolution. Therefore, it is common practice in these detector systems to perform a time calibration in order to compensate for inter-channel mis-synchronisation. This consists of finding a fixed time offset T^{(0)} , for each readout channel, such that: t_{\text{meas}}+T^{(0)}=t_{\text{exp}}=t_{\text{ref}}+t_{\text{transit}}, (1.1) where t_{\text{meas}} is the time measured by the channel, t_{\text{exp}} is the expected time that the signal was created, t_{\text{transit}} is the time expected to elapse between the reference time t_{\text{ref}} and the recording of the signal, depending on the detector geometry, light propagation and light readout methods. This traditional method requires the estimation of the reference time through reconstruction of ionising particle tracks in the detector using uncalibrated data [ 10 ] . This adds complexity to the problem and potentially introduces track reconstruction biases, which can be avoided with the method we describe in section 3 , due to its iterative nature and independence from a fixed reference time. We present a general calibration method that exploits the correlation between different channels of the detector, and iteratively finds the time offsets for all the detector channels without requiring any reference time, making the time offset calibration computationally easier and unbiased. Similar concepts of exploiting pairs of hits in different detector channels have been used in other contexts as a time calibration method [ 11 , 12 ] ; in this work we present the mathematical principle on which our time calibration method stands, demonstrating its consistency and verifying its effectiveness by means of numerical simulations. We then present two real-life applications in high energy physics experiments where this method is used to enhance the time resolution performance. The applications presented are in the context of the T2K Near Detector (ND280): a fine-grained scintillating cubes based active neutrino target (Super Fine-Grained Detector, or SuperFGD), and a time-of-flight scintillating bars detector (ToF) [ 13 , 14 , 15 ] . 2 Pairs of hits highly correlated in time The method presented in this manuscript is based on the signal correlation between different readout channels in the detector. It is therefore important to introduce the concept of highly correlated hit pairs, or ‘matching hit pairs’ . When an ionising particle crosses a detector, it typically generates a signal (a ‘hit’) in multiple readout channels. Normally, if the same particle leaves a signal in two channels ch_{1} and ch_{2} respectively at times t_{1} and t_{2} , it is possible to compute the expected time difference between the two hits based on simple geometrical arguments, and without reconstructing the track inside the detector. This can be done, for example, by knowing the position of the readout units, or exploiting the adjacency of scintillating units read by different channels. If an estimation of the expected time difference can be performed for a pair of hits, the time of the two hits are highly correlated, and the pair is designated as a matching hit pair . In the ideal case where each single detector time measurement is unbiased, there is no discrepancy between the measured and expected time difference between matching hits. The calibration method here proposed is based on the global minimisation of the discrepancy between measured and expected time differences over a sample of hit pairs measured by any pair of readout channels in the detector. We define this discrepancy as \Delta : \Delta=\Delta t_{\text{meas}}-\Delta t_{\text{exp}}=(t_{1}-t_{2})-(s_{1}-s_{2}), (2.1) where t_{1} and t_{2} are the measured hit times, and s_{1} and s_{2} are the expected hit times, for the first and second hits respectively from a matching hit pair . The global minimisation of \Delta is performed iteratively and simultaneously for all channels, as outlined in the following. It is important to stress that, throughout the treatment presented here, the measured times and the expected times always appear respectively in the differences t_{1}-t_{2} and s_{1}-s_{2} , eliminating the need of a global reference time estimation. 2.1 Matching hits in the SuperFGD The SuperFGD is an active neutrino target composed of nearly two million optically isolated scintillating cubes of 1 cm side. It has 3D tracking and calorimetry capabilities and was recently installed in the near detector of the T2K experiment [ 13 ] . The scintillating material is polystyrene doped with 1.5 % paraterphenyl (PTP) and 0.01 % POPOP. Each cube is crossed by three wavelength-shifting (WLS) optical fibres, oriented along the three Cartesian directions, that guide the light to the surface of the detector where Silicon PhotoMultipliers (SiPMs) read the light signals out. The fibres cross the entire detector so that each fibre can carry the light generated in multiple cubes. A scheme of the detector geometry is provided in figure 1 . The importance of having an accurate time resolution in the SuperFGD is primarily motivated by the physics goal of measuring the kinetic