Computational modeling of Pulsed Field Ablation for pulmonary vein isolation
Ashkan Bagherzadeh, Nagib T Chalfoun, Tong Gao, Lik Chuan Lee · 2025
Read Computational modeling of Pulsed Field Ablation for pulmonary vein isolation by Ashkan Bagherzadeh, Nagib T Chalfoun, Tong Gao, Lik Chuan Lee (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-07133.txt.
Introduction
A newer way to stop erratic heartbeats burns nothing: strong electric pulses kill the faulty tissue around the lung veins while sparing neighbors. Ashkan Bagherzadeh, Nagib Chalfoun, Tong Gao, and Lik Chuan Lee simulate that treatment before it touches a patient in this 2025 paper. Their three-dimensional model, checked against published lab and computer results, rebuilds a real left atrium and runs three commercial catheter shapes through it.
Circle, flower, and basket catheters were compared across voltages on lesion volume, energy efficiency, and how fully the burn crosses the wall. The circular shape delivered energy most efficiently and covered its target best at lower voltages, while the basket made the largest lesions. The authors offer the framework as a planning bench for catheter design and dose choice in this fast-spreading therapy.
Catalog record
| CREATOR | Ashkan Bagherzadeh, Nagib T Chalfoun, Tong Gao, Lik Chuan Lee |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 34 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-07133
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Computational modeling of Pulsed Field Ablation for pulmonary vein isolation Ashkan Bagherzadeh, Nagib T Chalfoun, Tong Gao, Lik Chuan Lee Abstract Pulsed field ablation (PFA) has emerged as a non-thermal alternative to traditional thermal ablation techniques for the treatment of atrial fibrillation (AF). This study presents a patient-specific 3D computational framework to model the effects of PFA on pulmonary vein isolation (PVI). The modeling framework is rigorously validated against published numerical and experimental data, demonstrating strong agreement across a range of scenarios. Using realistic left atrial (LA) anatomy, commercially available circular, flower, and basket catheter configurations are simulated to evaluate lesion formation across different applied voltages. The performance of each catheter type is quantitatively assessed using multiple metrics, including lesion volume, energy delivery efficiency and transmurality. Simulation results show that circular catheters provide the highest energy delivery efficiency and target coverage at lower voltages, while basket catheters produce the largest lesion volumes. This framework offers a useful basis for exploring catheter design and treatment planning in PFA applications. 1 Introduction Atrial fibrillation (AF) is the most common form of arrhythmia that is caused by disorganized electrical impulses in the atria, which leads to irregular and rapid heart rates [ 1 ] . This condition significantly increases the risk of stroke and can contribute to the development of heart failure [ 2 ] . Catheter ablation is known as an effective and minimally invasive treatment method for controlling AF, especially in patients with persistent symptoms or those who do not respond well to medications [ 3 ] . Targeting primarily the pulmonary veins where abnormal electrical signals often initiate AF, the procedure has been shown to improve symptoms and reduce arrhythmia recurrence [ 4 ] . Catheter ablation for AF can be performed using different techniques, each with its own approach of targeting and isolating the sources triggering the arrhythmia. The most widely used techniques for AF ablation are radiofrequency ablation (RFA) [ 5 ] and cryoballoon ablation [ 6 ] , both utilizing thermal energy to ablate tissue. In recent years however, pulsed field ablation (PFA) has emerged as a promising alternative, where high voltage electric pulses are applied to selectively ablate tissue with minimal thermal injury and collateral damage [ 7 ] . In PFA, a catheter is introduced into the heart through a vascular access point, typically via the femoral vein. The catheter is guided to the left atrium with the help of advanced imaging techniques such as fluoroscopy and intracardiac echocardiography. Once it is positioned near the pulmonary veins or other targeted locations, the electrodes are deployed in various geometric configurations to deliver electric pulses. These pulses generate strong electric fields that disrupt cell membranes in the targeted area through a process called electroporation that causes irreversible damage to arrhythmogenic cells while sparing the adjacent tissues, including the nerves, esophagus, and coronary arteries. The non-thermal nature of PFA minimizes the risk of complications such as pulmonary stenosis or collateral injury, making it a promising approach for improving the safety and efficacy of AF ablation. Figure 1 : Schematic of PFA targeting pulmonary vein tissues and the catheter’s path into the left atrium Numerical simulations can play an important role in advancing our understanding and optimization of PFA by offering insights into electric field distribution, lesion predictability, and treatment planning that are difficult to obtain through experimentation alone. Most computational PFA models focus on the tissue or organ scale, assuming homogeneous properties and employing macroscopic electroporation thresholds. Some efforts, such as Krassowska and Filev’s single-cell model [ 8 ] , explore the process at the cellular level, simulating transmembrane voltage dynamics and pore formation. However, clinical decision-making and device optimization typically depend on tissue-scale predictions. At the tissue level, simulation studies have demonstrated how lesion characteristics depend on variables like voltage amplitude and catheter placement. Meckes et al. 2022 showed nonlinear relationships between applied voltage and lesion depth, while Gómez-Barea et al. 2022 reported that PFA lesions are more symmetric and less affected by blood flow compared to thermal methods. Ji et al. 2022 found that sequential pulsing in multielectrode catheters enhances transmural lesion continuity. These findings underscore the utility of computational models in guiding energy delivery protocols and catheter design. Several prior studies have examined the influence of catheter geometry and configuration on electric field patterns. Marino et al. 2021 an open-source simulation platform (openEP) for modeling electroporation with variable tissue and pulse parameters, although its main applications focus on electrochemotherapy. Belalcazar and colleagues [ 13 , 14 ] explored how minor differences in electrode positioning or catheter shape can significantly affect lesion predictability, highlighting the sensitivity of outcomes to design parameters. While simulations provide powerful tools for predicting electric field behavior and guiding PFA design, experimental validation remains essential to confirm their biological relevance. Yao et al. 2017 demonstrated that combining high- and low-voltage pulses significantly enlarges ablation zones and induces measurable thermal effects, highlighting the importance of considering pulse protocol design. Preclinical work by Kawamura et al. 2022 in porcine models confirmed that lesion characteristics vary with catheter orientation and pulse repetition—findings consistent with prior numerical studies. Howard et al. 2022 highlighted the critical role of electrode-tissue proximity, showing that even small offsets can markedly alter lesion formation. Arena et al. 2012 further explored these dynamics in a controlled in vitro setup using a 3D tumor model, quantifying electroporation thresholds in tissue-mimicking materials. The aim of this work is to develop a 3D patient-specific computational modeling framework with anatomically realistic geometries to simulate PFA in clinically relevant scenarios. Particular attention is given to modeling commercially available catheter designs—circular, flower, and basket configurations—with detailed electrode geometries derived from manufacturer specifications to closely match clinical practice. This study also systematically investigates how catheter design and configuration affect performance under similar conditions using different metrics. The framework is rigorously validated against previously published experimental and computational benchmarks, ensuring reliable predictions across various scenarios. This computational framework establishes a foundation for patient-specific PFA simulations in future research. The structure of the paper is as follows: Section 2 outlines the computational framework, encompassing the mathematical formulation of the problem and the geometry. Section 3 focuses on the validation process and the simulation results. In Section 4, the findings are discussed in detail. Finally, Section 5 provides the concluding remarks of the study. 2 Methods Here, we provide an overview of the left atrium (LA) and pulmonary vein geometries as well as catheter design and specifications utilized in this study. Governing equations, thermophysical properties, and simulation settings are also outlined here. 2.1 Left atrium geometry Figure 2 shows the geometry of LA with key anatomical features, which are namely, the left superior pulmonary vein (LSPV), left inferior pulmonary vein (LIPV), right superior pulmonary vein (RSPV), right inferior pulmonary vein (RIPV), left atrial appendage (LAA), and the mitral valve (MV) opening. The simulation domain consists of a region of the LA extending to the LSPV, which has an inlet diameter \sim 14.5 mm and a wall thickness of 1 mm. The ablation target is located in LSPV ostia (see region defined by the blue-dotted line) and has a total volume of 385 mm 3 . Figure 2 : (a) LA geometry with