4D operando X-ray nano-holo-tomography reveals multiscale chemomechanics in Silicon-Graphite anode

Victor Vanpeene, Olga Stamati, Francois Cadiou, Quentin Jacquet, Julie Villanova, Sandrine Lyonnard · 2025

Read 4D operando X-ray nano-holo-tomography reveals multiscale chemomechanics in Silicon-Graphite anode by Victor Vanpeene, Olga Stamati, Francois Cadiou, Quentin Jacquet, Julie Villanova, Sandrine Lyonnard (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-06413.txt.

Introduction

Victor Vanpeene and co-authors film a battery anode at work, in four dimensions and at nano scale, in a 2025 paper. The anode blends silicon and graphite, a high-capacity mix whose swelling and cracking shorten cell life. Their tool is live X-ray holo-tomography at a synchrotron, paired with a method that tracks how each speck of the material moves between frames. One formation cycle gets watched.

The film sorts what truly drives local action. Fast diffusion channels rule, balancing the depth bias set by slow ion and electron travel. Particle shape, seat in the layer, nearness to silicon clusters, wetting by the liquid, and strain each play a part, but not equal parts. The team ranks the factors on one scale of sway. That ranking, they say, hands makers a practical order of attack: fix the channels first.

Catalog record

CREATORVictor Vanpeene, Olga Stamati, Francois Cadiou, Quentin Jacquet, Julie Villanova, Sandrine Lyonnard
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE87 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2508-06413

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

4D operando X-ray nano-holo-tomography reveals multiscale chemomechanics in Silicon-Graphite anode Victor Vanpeene, Olga Stamati, Francois Cadiou, Quentin Jacquet, Julie Villanova, Sandrine Lyonnard Abstract Linking electrode microstructure to electrochemical performance is essential for optimizing Li-ion batteries. However, this requires mechanistic 4D observations at ultimate spatio-temporal scales, which remains elusive. Here we demonstrate the use of operando synchrotron X-ray nano-holo-tomography combined with Digital Volume Correlation to track chemomechanical dynamics at both particle (local) and electrode (averaged) scales. Quantitative scale-bridging image analysis is applied to a high-capacity silicon-graphite anode during its formation cycle. Our findings reveal that local diffusion properties, graphite particle morphology and position in the electrode, distance to silicon clusters, surface contact with electrolyte and mechanical deformations, all have a direct impact on the local electrochemical activity and irreversibility - but these parameters are not equally important. Particularly, we identify fast diffusion channels that play a key role and counterbalance intrinsic depth-dependent reaction heterogeneities due to ionic/electronic diffusion limitations. The various structural factors that determine Gr-Si battery performance beyond ensemble properties are classified using a scale of influence, providing a practical framework for the optimization of materials and electrode manufacturing. keywords operando, phase contrast, X-ray nano-tomography, digital volume correlation, graphite silicon composite electrode 1 Introduction Degradation and irreversible morphological changes in Li-ion battery electrodes are complex intertwinned phenomena, involving cracking and disconnections of particles, pore clogging, solid electrolyte interphase (SEI) growth, localized strains and deformations, resulting overtime in continuous loss of cyclable lithium and anticipated cell failure. Narayan et al. 2022 The heterogeneity and amplitude of these degradation mechanisms mainly depend on the electrode microstructure and active material properties, highlighting the need to reversely optimize the electrode microstructures to achieve the required electrochemical performance and durability. However, precisely controlling and tailoring the porous microstructure of an electrode is very difficult. It depends on both the mixed materials - active particles, binders, coatings and additives - and the manufacturing process, Chouchane et al. 2019 from slurry preparation, film casting, drying, calendaring, to cell assembly. Franco et al. 2019 ; Ngandjong et al. 2021 Consequently, current state-of-the-art electrode optimization relies on tuning empirically a limited set of averaged parameters, such as active particle size distribution, volume fractions, macroscopic porosity, averaged tortuosity and electrode thickness. These parameters have a direct influence on electronic and ionic transport/transfer mechanisms, thereby affecting the efficiency and reversibility of electrochemical reactions. However, they do not capture the 3D multiscale complexity of electrode structures, their evolving topology and local mechanics, as well as the spatial distribution of solid and liquid phases. Therefore, to establish the structure-performance relationship beyond trial-and-error approaches, understanding the intricate chemomechanical interactions and how they regulate electrochemical activity is crucial. de Vasconcelos et al. 2022 Analysing the coupling between structure, morphology, stress, reactions and transport pathways requires advanced methodologies to simultaneously monitor the electrode dynamics and chemomechanical evolution at both particle (local) and electrode (averaged) scales. Experimentally, this is challenging due to (i) the need to spatially resolve heterogeneities spanning over multiple length scales, (ii) the difficulty to detect and quantify poorly-contrasting phases, typically porous network, binder and other organic species/layers, Cadiou et al. 2020 and (iii) the evolving nature of the microstructure during cycling. Hence, 3D space-resolved approaches with ultimate/tuneable resolutions are needed to determine the electrode hierarchical structure, Scharf et al. 2022 ; Lu et al. 2020 in combination with representative operando conditions to capture the dynamic changes during electrode (de)lithiation. Liu et al. 2019 Several techniques are available, each typically specializing in tackling one of the three aforementioned challenges - but none of them is capable of taking them simultaneously. High resolution studies probing heterogeneities at the particle scale were reported by STEM-EELS, Boniface et al. 2016 ; Xiong et al. 2022 optical microscopy, Pandya et al. 2023a ; Pandya et al. 2023b ; Kim et al. 2023 STXM, Li et al. 2020 ; Zhao et al. 2023 Ptychography, Müller et al. 2020 XRD-CT Finegan et al. 2019 ; Pietsch et al. 2016 or BCDI Martens et al. 2023 ; Vostrov et al. 2025 . They provided key insights into lithiation mechanisms by imaging reaction front propagations, interfacial transfer mechanisms, local strains and phase/species spatial distributions. However, with these techniques, only limited selections of active particles in given states of charge (SoC) are randomly measured, raising concerns about representativeness and universality of the findings. FIB-SEM has also been used to probe electrode microstructures in 3D with nanoscale resolution, analyzing SEI and particle morphology evolutions induced by charging and discharging Liu et al. 2025 ; Perrenot et al. 2024 ; Heitz et al. 2025 . Coupling with chemical information was brought by using complementary techniques as ToF-SIMS Bordes et al. 2016 ; Sui et al. 2015 and XPS. Li et al. 2010 Nevertheless, the probed volumes remain small due to hours-long acquisition time and the technique itself is quasi exclusively restricted to ex situ analyses, as FIB milling is destructive. Alternatively, X-ray computed tomography (CT) techniques offer the advantage of being non-invasive, 3D by nature, versatile towards analyzing a wide range of chemistries, Scharf et al. 2022 ; Pietsch and Wood 2017 ; Vanpeene et al. 2025 probing representative volumes and reaching excellent spatio-temporal resolutions when used at a synchrotron facility (from \mu m down to several hundreds of nm , from hours to minutes). Synchrotron micro-CT has been widely used in the battery community primarily at the cell and component level. Pietsch and Wood 2017 ; Bond et al. 2025 ; Finegan et al. 2015 Recent studies reported defects in cylindrical geometries due to manufacturing or aging, Lübke et al. 2024 ; Jnawali et al. 2024 geometry-dependent electrolyte motions, Bond et al. 2025 component distortions and delaminations, Jnawali et al. 2024 etc . In combination with far-field high-energy diffraction microscopy, micro-CT was also used to monitor grain-level strain responses in garnet-type solid electrolytes, revealing a stochastic failure mechanism affected by local microstructural heterogeneity. Dixit et al. 2022 Advanced chemomechanical quantification can be also obtained by applying 3D image analysis techniques in timeseries CT data. For example, Digital Volume Correlation (DVC), Bay et al. 1999 ; Geers et al. 1996 allows for the measurement of 3D kinematic fields, displacements and the derived strains, which can in turn be decomposed into an isotropic ( i.e. , spherical) and deviatoric part, enabling analysis of volume and shear distortions. The DVC approach has been applied to different types of battery electrode materials, such as {LiMn_{2}O_{4}} Eastwood et al. 2014 and graphite Pietsch et al. 2016 yielding information about mechanical failure modes at mesoscopic scales. More recently Valisammagari et al. Valisammagari et al. 2025 applied it to Gr-Si electrodes at the mesoscopic scale and found a relationship between the local strain distribution and the electrode microstructure, but the restricted spatial resolution used did not allow establishing a comprehensive relationship between local microstructure rearrangement and electrode activity/reversibility. Despite these advances, reported works at the electrode/cell level generally lack submicron information due to their limited spatial resolution, which is mandatory for particle-scale analysis. X-ray nano-computed tomography Scharf et al. 2022 overcomes this limitation. In particular, the propagation-based phase-contrast approach Cloetens et al. 1999 ; Zabler et al. 2005 (so-called X-ray nano-holo-tomography, nano-CT) provides phase segmentation capabilities for low-attenuating materials, relevant for

Read the complete text