Error Accumulation using Linearized Models for Aggregating Flexibility in Distribution Systems
Yanlin Jiang 2 , Xinliang Dai 1 , Frederik Zahn 2 , Yi Guo 3 , and Veit Hagenmeyer 2 · 2025
Read Error Accumulation using Linearized Models for Aggregating Flexibility in Distribution Systems by Yanlin Jiang 2 , Xinliang Dai 1 , Frederik Zahn 2 , Yi Guo 3 , and Veit Hagenmeyer 2 (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-04382.txt.
Introduction
Yanlin Jiang and co-authors wrote this power systems paper, published in two thousand twenty-five, on summing up the flexibility of a local grid with simple linear models. Grid operators use such sums to know how much a district's demand and solar output can shift.
The paper lays out the theory behind several linear flow models and the assumptions each one hides, from network shape to voltage limits and line losses. Simulations run on a real campus network in Germany, fed with measured demand and solar data. The linear models tend to understate line losses, the authors find. The errors also pile up at the link point with the wider grid and grow over long time spans. The study warns planners that cheap linear stand-ins can drift far from the true system.
Catalog record
| CREATOR | Yanlin Jiang 2 , Xinliang Dai 1 , Frederik Zahn 2 , Yi Guo 3 , and Veit Hagenmeyer 2 |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 23 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-04382
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Error Accumulation using Linearized Models for Aggregating Flexibility in Distribution Systems 1 Corresponding Author: X. Dai ([email protected]). Yanlin Jiang 2 , Xinliang Dai 1 , Frederik Zahn 2 , Yi Guo 3 , and Veit Hagenmeyer 2 Abstract This paper investigates flexibility aggregation approaches based on linear models. We begin by examining the theoretical foundations of linear AC power flow, two variants of so-called DC power flow, and the LinDistFlow model, along with their underlying assumptions. The discussion covers key system details, including network topology, voltage constraints, and line losses. Simulations are conducted on the KIT Campus Nord network with real demand and solar data. Results show that, in the absence of negative losses, line losses are generally underestimated by linear models. Furthermore, line losses errors tend to accumulate both at the point of common coupling (PCC) and over extended time horizons. I Introduction In recent decades, the integration of distributed energy resources (DERs) into power systems has grown rapidly, with most of these resources being decentralized and connected to distribution networks. This shift requires closer TSO-DSO collaboration to ensure efficient and secure DERs ’ mangement [ 1 , 2 ] . While a centralized management approach could, in theory, optimize the entire power system, it is impractical due to computational limits, privacy concerns, and high communication demands [ 3 , 4 , 5 ] . As an alternative, flexibility aggregation provides a non-iterative distributed coordination framework: each DSO independently determines its implicit feasible set of net power exchange with the TSO , within which safe operation of the distribution system can be ensured [ 6 ] . However, accurately characterizing this feasible set is challenging because of the nonlinearity in AC power systems, making the dispatch problem NP-hard even for radial networks [ 7 ] . Several linear models have been developed to simplify the power flow problem. Among them, the DC power flow model [ 8 ] is one of the most widely used. However, this model is lossless and primarily designed for transmission systems, where voltage and angle differences are minor, and branch reactances dominate over resistances; these assumptions are typically not valid in distribution networks. Another lossless approach is the LinDistFlow model, a simplification of the DistFlow model that neglects power losses [ 9 ] . LinDistFlow is formulated explicitly for radial distribution networks, reflecting their typical topological characteristics. To incorporate power losses into linear models, two main approaches are typically used: either the power losses themselves are linearized, or the full AC power flow equations are linearized directly. For the former, the enhanced DC model is proposed [ 10 ] . 1 1 1 The model introduced in [ 10 ] is referred to as the linearized optimal power flow model. To distinguish it from other linear models discussed in this paper, we refer to it as the enhanced DC power flow model. This model adopts the common assumptions of small voltage magnitude and angle differences to eliminate trigonometric functions, and power losses are explicitly linearized. By contrast, the linearized AC power flow model is derived without relying on such assumptions. Instead, once a power flow solution is obtained, the system Jacobian is used to capture the relationship between system variables and demand [ 11 ] . Leveraging the convexity of the linear models, different flexibility aggregation methods have been introduced to aggregate flexibility. These include outer approximations [ 12 ] , inner approximations [ 13 , 14 , 15 ] , boundary detection techniques [ 6 , 16 ] , data-driven approaches [ 17 ] , and projection-based methods such as Fourier-Motzkin elimination [ 18 ] . Building on this, [ 19 ] employs a temporal decomposition strategy, allowing the feasible region at each time step to be computed independently and in parallel. However, both the omission of line losses and the use of linearized models can lead to significant inaccuracies in flexibility aggregation. As shown in [ 9 , 20 ] , flexibility derived from the LinDistFlow model often deviates from results based on the exact AC model. Additionally, linearization of losses may even result in physically unrealistic outcomes, such as negative losses. To mitigate this, [ 10 ] proposes adding a penalty term to the objective function. However, such techniques are difficult to incorporate into flexibility aggregation frameworks. The approach in [ 20 ] aggregates flexibility at a specific time point. We build on these results to reveal the impact of system losses on the multiperiod scheduling problem. To this end, we first provide a comprehensive review of linear models used for flexibility aggregation. A real distribution network is then used to evaluate different models for flexibility aggregation and solve the corresponding scheduling problem. Our results show that, in open-loop scheduling scenarios, underestimated power losses accumulate over time. This leads to over-discharging of the energy storage systems (ESS) , highlighting the importance of incorporating real-time feedback or correction mechanisms into the scheduling process. II AC Power Flow Models This section presents two variants of AC power flow equations for power systems, both derived from the complex power flow formulation. II-A Preliminaries A power system can be represented as a graph \mathcal{S}=(\mathcal{N},\mathcal{L}) , where \mathcal{N} denotes the set of buses and \mathcal{L} the set of branches. The subsets \mathcal{L}^{f} and \mathcal{L}^{t} correspond to the from-side and to-side branches, respectively. The AC power flow equations describe the fundamental relationships among key quantities in the power system, namely current I , voltage V , admittance Y , and power S . Three fundamental electrical principles underpin these equations. First, Kirchhoff’s Current Law (KCL) states that the sum of currents flowing into and out of a bus must be balanced. Mathematically, this is expressed as \qquad\qquad I_{i}=\sum_{(i,j)\in\mathcal{L}}I_{ij},\qquad\qquad\forall i\in\mathcal{N} (1) where I_{i} denotes the current injection from devices, including load and generator, at bus i , and I_{ij} is the current along branch (i,j) . Second, Ohm’s Law relates the current along a branch to the voltage difference between its terminals: \qquad\qquad I_{ij}=Y_{ij}(V_{i}-V_{j}),\qquad\qquad\forall(i,j)\in\mathcal{L} (2) with Y_{ij} being the admittance of the branch between buses i and j . For more on the admittance matrix Y , see [ 21 , Sec. 4] . Third, the definition of AC power specifies the complex power flow \qquad\qquad S_{ij}=Y_{i}I^{*}_{ij},\qquad\qquad\forall(i,j)\in\mathcal{L} (3) where V_{i} is the voltage at bus i and I^{*}_{ij} is the complex conjugate of the branch current. By combining these properties, we obtain the standard AC power flow model. The power balance at each bus i is \displaystyle S_{i}= \displaystyle\sum_{(i,j)\in\mathcal{L}}S_{ij}, \displaystyle\forall i\in\; \displaystyle\mathcal{N} (4a) and the power flow along branch (i,j) is \displaystyle S_{ij}= \displaystyle\quad Y^{*}_{ij}V_{i}V_{i}^{*}-Y_{ij}^{*}V_{i}V_{J}^{*},\; \displaystyle\forall(i,j)\in\; \displaystyle\mathcal{L}, (4b) Collectively, these nonlinear equations ( 4 ) form the foundation for many power system applications, governing nodal power balance and power flows across the network. II-B AC Power Flow Equations in Polar Coordinates When voltages are represented in polar coordinates, \displaystyle V_{i}=v_{i}e^{\,\textbf{j}\theta_{i}},\quad\forall i\in\mathcal{N}, (5) the AC power flow equations ( 4 ) can be reformulated in terms of these polar coordinates: \displaystyle p_{i}=v_{i}\sum_{j\in\mathcal{N}}v_{j}\left(g_{ij}\cos\theta_{ij}+b_{ij}\sin\theta_{ij}\right), \displaystyle\forall i \displaystyle\in\mathcal{N}, (6a) \displaystyle q_{i}=v_{i}\sum_{j\in\mathcal{N}}v_{j}\left(g_{ij}\sin\theta_{ij}-b_{ij}\cos\theta_{ij}\right), \displaystyle\forall i \displaystyle\in\mathcal{N}, (6b) where v_{i} and \theta_{i} are the magnitude and angle of the complex voltage V_{i} , g_{ij} and b_{ij} are the real and imaginary parts of the admittance