Advanced SQUID-on-lever scanning probe for high-sensitivity magnetic microscopy with sub-100-nm spatial resolution
Timur Weber, Daniel Jetter, Jan Ullmann, Simon A. Koch, Simon F. Pfander, Katharina Kress, Andriani Vervelaki, Boris Gross, Oliver Kieler, Ute Drechsler, Priya R. Baral, Arnaud Magrez, Reinhold Kleiner, Armin W. Knoll, Martino Poggio, Dieter Koelle · 2025
Read Advanced SQUID-on-lever scanning probe for high-sensitivity magnetic microscopy with sub-100-nm spatial resolution by Timur Weber, Daniel Jetter, Jan Ullmann, Simon A. Koch, Simon F. Pfander, Katharina Kress, Andriani Vervelaki, Boris Gross, Oliver Kieler, Ute Drechsler, Priya R. Baral, Arnaud Magrez, Reinhold Kleiner, Armin W. Knoll, Martino Poggio, Dieter Koelle (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-01927.txt.
Introduction
Weber and co-authors build a SQUID probe on a lever for fine field shots. SQUIDs are keen field tools that catch weak fields in gear. Shrunk SQUIDs on scan tips give sharp shots at low heat. Their tools are niobium loops with cores down to 10 nm. Loops sit at the tip of flat silicon levers in the build. Wafer print and beam cuts shape the loops in two steps.
The probes beat 100 nm in shot sharp mark in tests. Flux keen marks hit 0.3 in the set scale per root Hz. They work in fields up to near 0.5 T at 4.2 K. Ne or He beam cuts can add a tune line to the probe. A third joint can shift the loop's phase in that build. Tough builds clear past probe caps in the same runs.
Catalog record
| CREATOR | Timur Weber, Daniel Jetter, Jan Ullmann, Simon A. Koch, Simon F. Pfander, Katharina Kress, Andriani Vervelaki, Boris Gross, Oliver Kieler, Ute Drechsler, Priya R. Baral, Arnaud Magrez, Reinhold Kleiner, Armin W. Knoll, Martino Poggio, Dieter Koelle |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 42 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-01927
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Advanced SQUID-on-lever scanning probe for high-sensitivity magnetic microscopy with sub-100-nm spatial resolution Timur Weber, Daniel Jetter, Jan Ullmann, Simon A. Koch, Simon F. Pfander, Katharina Kress, Andriani Vervelaki, Boris Gross, Oliver Kieler, Ute Drechsler, Priya R. Baral, Arnaud Magrez, Reinhold Kleiner, Armin W. Knoll, Martino Poggio, Dieter Koelle Abstract Superconducting quantum interference devices (SQUIDs) are exceptionally sensitive magnetometers capable of detecting weak magnetic fields. Miniaturizing these devices and integrating them onto scanning probes enables high-resolution imaging at low-temperature. Here, we fabricate nanometer-scale niobium SQUIDs with inner-loop sizes down to 10 nm 10\text{\,}\mathrm{nm} at the apex of individual planar silicon cantilevers via a combination of wafer-scale optical lithography and focused-ion-beam (FIB) milling. These robust SQUID-on-lever probes overcome many of the limitations of existing devices, achieving spatial resolution better than 100 nm, magnetic flux sensitivity of 0.3 µ Φ 0 / 0.3\text{\,}\mathrm{\SIUnitSymbolMicro\text{$\Phi_{0}$}}\text{/}\mathrm{} , and operation in magnetic fields up to about 0.5 T at 4.2 K. Nanopatterning via Ne- or He-FIB allows for the incorporation of a modulation line for coupling magnetic flux into the SQUID or a third Josephson junction for shifting its phase. Such advanced functionality, combined with high spatial resolution, large magnetic field range, and the ease of use of a cantilever-based scanning probe, extends the applicability of scanning SQUID microscopy to a wide range of magnetic, normal conducting, superconducting, and quantum Hall systems. We demonstrate magnetic imaging of skyrmions at the surface of bulk Cu 2 OSeO 3 \text{Cu}_{2}\text{OSeO}_{3} . Analysis of the point spread function determined from imaging a single skyrmion yields a full-width-half-maximum of 87 nm. Moreover, we image modulated magnetization patterns with a period of 65 nm. I Introduction Magnetic microscopy – because of its ability to reveal magnetization patterns and current distributions – is crucial for studying the properties of magnetic, normal conducting, and superconducting materials. Unlike bulk measurements, which integrate over entire samples, magnetic imaging reveals information about length scales, inhomogeneities, and interactions. A wide variety of techniques, including scanning probe microscopy, light microscopy, and electron microscopy, are available for an even wider variety of materials and conditions Christensen et al. 2024 . Scanning superconducting quantum interference device (SQUID) microscopy (SSM) is particularly well-suited for sensitive and high-resolution imaging of transport and magnetization at low temperatures. In recent years, SSM has been used to explore magnetism in nanostructures Vasyukov et al. 2018 ; Wyss et al. 2019 , at complex oxide interfaces Bert et al. 2011 ; Christensen et al. 2019 ; Wang et al. 2015 , in topological insulators Lachman et al. 2015 , and in few-layer 2-dimensional (2D) magnets Noah et al. 2023 ; Zur et al. 2023 ; Vervelaki et al. 2024 ; Bagani et al. 2024 , as well as allowing for the imaging of orbital magnetism in bilayer graphene Tschirhart et al. 2021 . SSM was also used to image current flow in both a quantum spin Hall Nowack et al. 2013 and a quantum anomalous Hall insulator Ferguson et al. 2023 , in graphene in the quantum Hall regime Uri et al. 2020a , in magic-angle twisted bilayer graphene Uri et al. 2020b , at oxide domain walls Kalisky et al. 2013 , and in WTe 2 in a regime where electrons flow hydrodynamically Aharon-Steinberg et al. 2022 . In the area of superconductivity, SSM has long been a central tool for discovery, e.g. on the nature of the order parameter symmetry in cuprate superconductors Persky et al. 2022a ; Kirtley 2010 . Most recently, SSM was used to observe the flow of superconducting vortices in a Pb film Embon et al. 2017 and quantum fluctuations near criticality in NbTiN Kremen et al. 2018 . It enabled the discovery of a hidden magnetic phase above the superconducting transition temperature of the van der Waals superconductor 4Hb-TaS 2 Persky et al. 2022b , as well as vortex excitations carrying a temperature-dependent fraction of the flux quantum \Phi_{0} Iguchi et al. 2023 . At the moment, there are two main types of high-resolution SSM. The first is based on a so-called SQUID-on-chip sensor, in which the superconducting device is fabricated via standard lithography on a chip, and a small, spatially separated pick-up loop, often at the corner of the chip, couples the sensor to the sample of interest Kirtley et al. 1995 ; Koshnick et al. 2008 ; Kirtley et al. 2016 . These SQUIDs can be fabricated in large quantities and have the advantage of including on-chip circuitry such as flux modulation coils and a coil for magnetic susceptibility measurements. However, their spatial resolution is typically in the micrometer range, due to the size of the pick-up loop and limitations on the minimum SQUID-to-sample distance Persky et al. 2022a ; moreover, they only function in magnetic fields up to about 10 mT, because of the properties of the Nb/AlO x /Nb Josephson junctions (JJs) Huber et al. 2008 . A second type of sensor, known as a SQUID-on-tip, consists of a SQUID loop that is fabricated directly at the apex of a quartz capillary via a three-step deposition of superconducting material Finkler et al. 2010 ; Vasyukov et al. 2013 . The JJs of these SQUIDs are Dayem bridges (or constriction junctions), allowing for SQUIDs with diameters less than 100 nm and critical fields in the Tesla range Bagani et al. 2019 . This combination results in SSM probes with sub-micrometer spatial resolution that operate in a high magnetic field beyond 1\text{\,}\mathrm{T} . However, the process by which SQUID-on-tips are fabricated precludes the application of conventional wafer-scale processing and the integration of circuitry such as a modulation coil for controlling the flux coupling into the SQUID or for local magnetic susceptibility measurements. Moreover, the choice of superconducting materials is limited by the non-planar surfaces on which they must be deposited or grown. Magnetic flux sensitivities of both types of SSM probes typically range from hundreds of n \Phi_{0}/\sqrt{\text{Hz}} to a few µ \Phi_{0}/\sqrt{\text{Hz}} at 4.2 K José Martínez-Pérez and Koelle 2017 . Recently, nanometer-scale SQUIDs based on Dayem bridge JJs have been realized at the tip of modified commercial Si cantilevers for atomic force microscopy (AFM) using a process based on focused ion beam milling (FIB) Wyss et al. 2022 . Here, we go significantly beyond this initial proof-of-concept by realizing Nb nanoSQUIDs that are integrated on custom-made Si cantilevers. We use wafer-scale thin-film deposition and optical lithography to produce cantilever chips that contain prepatterned Nb microstructures on planar cantilevers. We combine this with a final FIB milling step, to fabricate sensors reproducibly and in large quantities. This process yields robust SQUID-on-lever sensors that allow for a well-controlled surface approach, magnetic imaging with spatial resolution better than 100 nm, a magnetic flux sensitivity of 0.3 µ \Phi_{0}/\sqrt{\text{Hz}} , operation in magnetic fields up to \sim 0.5 T, and the integration of on-tip circuitry, including a modulation line or a third JJ to flux-bias or phase-bias the devices at their optimum working point. We demonstrate the capabilities of these sensors by imaging nanometer-scale magnetic configurations at the surface of the chiral magnet \text{Cu}_{2}\text{OSeO}_{3} . Endowed with the advantages of both SQUID-on-chip and SQUID-on-tip sensors, the resulting probes promise to expand the reach of SSM to a variety