Cryogenic RF-to-Microwave Transducer based on a DC-Biased Electromechanical System
Himanshu Patange, Kyrylo Gerashchenko, Rémi Rousseau, Paul Manset, Léo Balembois, Thibault Capelle, Samuel Deléglise, Thibaut Jacqmin · 2025
Read Cryogenic RF-to-Microwave Transducer based on a DC-Biased Electromechanical System by Himanshu Patange, Kyrylo Gerashchenko, Rémi Rousseau, Paul Manset, Léo Balembois, Thibault Capelle, Samuel Deléglise, Thibaut Jacqmin (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-01066.txt.
Introduction
Patange and co-authors report in 2025 a cold device that converts radio frequency signals into microwaves in two stages. A tuned electrostatic pre amplifier joins a superconducting electromechanical cavity. A metal coated membrane forms one plate of a capacitor inside that cavity.
A steady voltage across the gap turns small radio signals into a force scaled by that voltage, which gives gain set by a dial. The device ran at near absolute zero in tests. At a set bias it reached a fine charge sensitivity. Forecasts for thinner gaps and better membranes point to far finer sensitivity, toward quantum grade radio sensing.
Catalog record
| CREATOR | Himanshu Patange, Kyrylo Gerashchenko, Rémi Rousseau, Paul Manset, Léo Balembois, Thibault Capelle, Samuel Deléglise, Thibaut Jacqmin |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 39 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-01066
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Cryogenic RF-to-Microwave Transducer based on a DC-Biased Electromechanical System Himanshu Patange, Kyrylo Gerashchenko, Rémi Rousseau, Paul Manset, Léo Balembois, Thibault Capelle, Samuel Deléglise, Thibaut Jacqmin Abstract We report a two-stage, heterodyne rf-to-microwave transducer that combines a tunable electrostatic pre-amplifier with a superconducting electromechanical cavity. A metalized Si 3 N 4 membrane (3 MHz frequency) forms the movable plate of a vacuum-gap capacitor in a microwave LC resonator. A dc bias across the gap converts any small rf signal into a resonant electrostatic force proportional to the bias, providing a voltage-controlled gain that multiplies the cavity’s intrinsic electromechanical gain. In a flip-chip device with a 1.5 µm gap operated at 10 mK we observe dc-tunable anti-spring shifts, and rf-to-microwave transduction at 49 V bias, achieving a charge sensitivity of 87 µe/ Hz \sqrt{\mathrm{Hz}} (0.9 nV/ Hz \sqrt{\mathrm{Hz}} ). Extrapolation to sub-micron gaps and state-of-the-art Q > 10 8 Q>10^{8} membrane resonators predicts sub-200 fV/ Hz \sqrt{\mathrm{Hz}} sensitivity, establishing dc-biased electromechanics as a practical route towards quantum-grade rf electrometers and low-noise modular heterodyne links for superconducting microwave circuits and charge or voltage sensing. 1 Introduction Bridging the gap between radio-frequency (rf) and microwave-frequency electrical signals is a longstanding challenge in quantum electronics and precision sensing. If an rf signal can be up-converted without adding noise, it can be processed by near-quantum-limited amplifiers that are available in the microwave frequency band. In a typical electro-mechanical transducer, an rf charge modulation drives a mechanical mode into motion. The motion is then converted into a microwave sideband that can be measured with sub-nV/ \sqrt{\mathrm{Hz}} sensitivity. Such a device can also be used as a sensitive electrometer. The seminal electrometer of Knobel and Cleland exploits a radio-frequency single-electron transistor to measure the motion of a suspended beam and achieves a charge sensitivity of 12 µe/ \sqrt{\mathrm{Hz}} [ 1 ] . Subsequent transport-based devices—rf-SETs [ 2 , 3 , 4 , 5 , 6 , 7 ] , rf-QPC [ 8 ] , quantum dots [ 9 , 10 , 11 ] , gate-based devices [ 12 ] , and fluxonium qubits [ 13 , 14 ] —have pushed sensitivities below 10 µe /\sqrt{\mathrm{Hz}} . A parallel track replaces the electronic detector with an optical or microwave cavity coupled to a high-Q mechanically compliant capacitor. In such schemes, one exploits the high susceptibility of the resonant mechanical system to probe an external force, such as an electrostatic modulation, with high sensitivity. Cavity-enhanced microwave read-out of a nanobeam was obtained at room temperature [ 15 ] . Additionally, ground-state cooling and imprecision at the standard quantum limit have been achieved in both microwave [ 16 , 17 , 18 ] and optical [ 19 , 20 , 21 , 22 ] domains, while ultracoherent Si 3 N 4 membranes with Q>10 9 [ 23 , 24 , 25 , 18 ] for mechanical modes in the 100 kHz range, now suppress thermomechanical force noise to the zeptonewton level [ 18 , 24 ] . Meanwhile, cavity electro-optomechanical converters have linked microwave and optical photons [ 26 , 27 , 28 , 29 , 30 ] . In most cavity-based converters the microwave cavity alone supplies the gain. The linearized coupling grows with the intracavity photon number, so that achieving higher conversion efficiency requires strong pumps—at the cost of photon shot-noise or heating. Here we report on a two-stage architecture that sidesteps that trade-off by pre-amplifying the rf signal electrostatically before it reaches the cavity. More precisely, we propose a heterodyne rf-to-microwave converter based on a dc-biased membrane. It consists of a metalized Si 3 N 4 membrane whose fundamental drum mode lies near 3 MHz. The membrane forms one plate of a vacuum-gap capacitor in a superconducting lumped-element LC resonator at 6 GHz, such that its motion modulates the microwave resonance frequency. A dc bias applied across the gap converts any small rf signal on the same line into a time-varying electrostatic force that scales linearly with the bias voltage [ 28 , 31 , 32 , 14 ] . This electrostatic stage adds a voltage - tunable pre - amplification to the RF signal before it is up-converted by the LC microwave resonator. Because the two stages act in series, their gains multiply, boosting the overall RF - to - microwave conversion. A related scheme was demonstrated at room temperature in Ref. [ 28 ] , where a sub - MHz rf voltage is converted to an optical carrier with a voltage sensitivity of a few pV/ \sqrt{\mathrm{Hz}} . In the present cryogenic implementation, we demonstrate a flip-chip assembly that realises a 1.5 µm vacuum gap, and observe dc-controlled frequency shifts on the mechanical modes — a static effect known as anti-spring effect [ 31 , 28 , 14 ] . With a 49 V bias, the device achieves a charge sensitivity of 87 µe/ \sqrt{\mathrm{Hz}} ( 0.9 nV/ \sqrt{\mathrm{Hz}} ), currently limited by bias-line noise. With sub-micrometer gaps and Q>10^{8} membranes already demonstrated [ 33 , 25 , 18 ] , our model predicts that sub-200 fV/ \sqrt{\mathrm{Hz}} sensitivity is within reach, paving the way towards quantum-grade rf electrometers and heterodyne links that integrate seamlessly with microwave quantum circuits. 2 Transduction principle Figure 1: Top: illustration of the transducer amplification chain, where the electrical spectrum S_{\mathrm{VV}} (signal \delta V_{s} at frequency \Omega_{\mathrm{RF}} plus white noise of spectral density S_{\mathrm{VV}}^{n} , indicated in purple) undergoes transduction to position spectrum S_{\mathrm{xx}} with the electrostatic gain \mathcal{G}_{\mathrm{V}} (electrical noise contribution appears in purple, and thermal noise contribution in orange) followed by transduction to microwave sideband spectrum S_{\mathrm{SB}} via the electromechanical gain \mathcal{G}_{\mathrm{em}} (detection noise contribution is indicated in light green). Bottom: proposed implementation of the transducer. An LC microwave resonator (red) of resonance frequency \omega_{\mathrm{c}} is coupled to a metalized free standing membrane acting as a mechanically compliant capacitor. The red part of the circuit is electrically floating. The membrane electrode (yellow) is biased through a capacitor C_{\mathrm{b}} , connected to a bias tee (pink rectangle) that combines the dc bias and an rf signal to drive membrane modes on resonance. The two halves of the membrane electrode behave as C_{m}(x)/2 capacitors that are connected in parallel for the microwave LC resonator, and in series for the bias-line, so that the bias circuit sees the full membrane capacitance C_{m}(x) whereas the resonator adds only C_{m}(x)/4 in parallel with the stray capacitance C_{\mathrm{s}} . The LC resonator is inductively coupled to a read-out line (green). A probe tone \alpha_{\mathrm{in}} at the red - detuned frequency \omega_{\mathrm{d}}=\omega_{\mathrm{c}}-\Omega_{\mathrm{m}} is sent into the resonator, and the reflected field \alpha_{\mathrm{out}} is monitored with a vector spectrum analyser. In this scheme, the mechanical mode of amplitude \delta x , is driven on resonance by the rf source, and amplified by the dc source with a gain \mathcal{G}_{V} . It is then upconverted and amplified with a gain \mathcal{G}_{\mathrm{em}} at microwave frequencies by the electromechanical system operating in the resolved sideband regime. It appears as a sideband of the reflected microwave carrier \alpha_{\mathrm{out}} . The proposed design, described in Fig. 1 , consists of a metalized membrane oscillator (mode frequency \Omega_{\mathrm{m}}/2\pi of a few MHz, and effective mass m_{\mathrm{eff}} ), dispersively coupled to a superconducting lumped-element