Pointwise Encoding Time reduction with Radial Acquisition (PETRA) to pseudo-CT mapping for precision Focused Transcranial Ultrasound Applications
Maria Miscouridou, Alisa A. Krokhmal, Aaron T. Hess, Jon Campbell, Charlotte J. Stagg, Eleanor Martin, Bradley E. Treeby · 2025
Read Pointwise Encoding Time reduction with Radial Acquisition (PETRA) to pseudo-CT mapping for precision Focused Transcranial Ultrasound Applications by Maria Miscouridou, Alisa A. Krokhmal, Aaron T. Hess, Jon Campbell, Charlotte J. Stagg, Eleanor Martin, Bradley E. Treeby (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2508-01050.txt.
Introduction
Maria Miscouridou and co-authors map a bone-friendly scan type to CT-like images in a 2025 arXiv paper on brain ultrasound care. Plans for sound treatment through the skull now rest on CT scans. CT use adds dose from X-rays, so groups seek stand-ins built from magnet scans. The PETRA scan type shows bone well, so the team paired it with CT scans of people and loose skulls.
A math step found a straight map from PETRA values to CT-like values in bone. Sound field tests on scans of living heads gave small errors in focus spot, peak force, and focus size. Errors on loose skulls matched CT-based ones, which backs the swap.
Catalog record
| CREATOR | Maria Miscouridou, Alisa A. Krokhmal, Aaron T. Hess, Jon Campbell, Charlotte J. Stagg, Eleanor Martin, Bradley E. Treeby |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 43 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2508-01050
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Pointwise Encoding Time reduction with Radial Acquisition (PETRA) to pseudo-CT mapping for precision Focused Transcranial Ultrasound Applications Maria Miscouridou, Alisa A. Krokhmal, Aaron T. Hess, Jon Campbell, Charlotte J. Stagg, Eleanor Martin, Bradley E. Treeby Abstract Ultrasound simulations used for treatment planning in transcranial ultrasound stimulation(TUS) currently depend on converting computed tomography(CT) images to acoustic properties. Aiming to reduce subject exposure to ionising radiation, recent literature focused on generating pseudo-CT images from different magnetic resonance(MR) imaging sequences. Here, the PETRA (pointwise encoding time reduction with radial acquisition) sequence was used because of its stronger ability to image bones. A dataset of paired CT and PETRA scans was acquired separately for human subjects and ex-vivo skulls. Principal component analysis performed on all bone voxels uncovered the affine relationship converting PETRA images to pseudo-CTs. Acoustic simulations based on CTs and pseudo-CTs were performed in k-Plan and k-wave. For in-vivo data, the mean absolute errors in focal position, peak pressure and focal volume were 0.48±0.25mm, 5.1±4.0% and 5.8±4.4%. The similarity of acoustic fields from ex-vivo CTs/pseudo-CTs was compared with experimental data. The corresponding errors were 1.5±1.2 mm, 17.1±14.6% and 32.5±22.5% for CT and 1.6±1.4 mm, 18.2±17.1% and 19.2±15.9% for pseudo-CT. The small errors for in-vivo data and the similarity of the experimental errors for both methods validate the use of PETRA-derived pseudo-CT as an alternative to CT, ensuring precise acoustic field predictions. The conversion tool is available at https://github.com/ucl-bug/petra-to-ct . I Introduction Transcranial ultrasound stimulation (TUS) is an emerging therapeutic technique that leverages ultrasound waves to modulate brain activity ( Darmani et al. 2022 ) . A factor that needs to be taken into account is the aberration caused to the waves by the skull. For this reason ultrasound simulations are currently used to aid with target guidance and dosimetry. Currently, simulations are paired with x-ray computed tomography (CT) images of individual subjects to generate personalised maps of the acoustic properties and predict how the ultrasound waves propagate through the bones ( Aubry et al. 2003 ; Marquet et al. 2009 ) . Although CT images are the gold standard for bone imaging, they are not always available and they expose patients to ionising radiation, which motivates us to explore methods that avoid CT scans. Our approach is to translate from magnetic resonance (MR) images to CT images. So far, classical and machine learning techniques have been used to generate pseudo-CTs (pCT) from a range of MR sequences, including T1-weighted, UTE (ultrashort echo time) and ZTE (zero echo time) ( Miscouridou et al. 2022 ; Su et al. 2020 ; Yaakub et al. 2023 ) . The existing literature on translating MR to CT can be divided into three different approaches. Before the use of machine learning, classical methods have been used to translate MR to pCT. First, piece-wise constant methods segment the MR into brain, skull and skin/background areas and use predefined values in Hounsfield Units for each area to generate a pCT ( Wintermark et al. 2014 ) . The segmentation process usually works quite well and the interfaces between different types of tissue can be identified accurately. However, one value in each segment results in the homogenisation of the internal structures and does not represent the complex microstructure. In particular, trabecular and cortical bone have different acoustic properties and treating them as homogeneous introduces errors in the simulation. Second, deep learning (DL) techniques have been shown to accurately map different types of MR images to pCTs. A more extensive review of such methods can be found in previous work ( Miscouridou et al. 2022 ) . T1-weighted MR images are most commonly used as they are the most prevalent in the medical field. These methods can provide more accurate predictions than classical methods for the smaller and more heterogeneous structures of the bone. However, they suffer from poor generalisation to new data, a common drawback of DL methods. Third, specialised MR sequences such as ZTE or UTE can be used to directly map to CT. These methods involve segmenting the MR and using direct mapping from them to pseudo-CT. Such specialised imaging protocols can capture bone signals with greater success compared to T1-weighted MRIs. Therefore, it is possible to infer an affine relationship between MR values and CT values in the bone. These can then be used to generate pCTs directly from MRIs ( Marquet et al. 2009 ) . Most conventional MRI techniques (such as T1-weighted) struggle to visualise structures such as bone and tendons because of their rapid signal decay. Specialised MRI techniques are used to overcome the challenges associated with imaging these tissues. The most common sequences that have demonstrated bone imaging are UTE Gatehouse and Bydder 2003 and ZTE ( Weiger and Pruessmann 2012 ) because of their short echo times. Another sequence that can be optimised to capture bone signals is PETRA (pointwise encoding time reduction with radial acquisition) ( Grodzki et al. 2012 ) . A low flip angle can be chosen to minimise T1 contrast in PETRA scans, affecting the appearance of tissues such as the cerebrospinal fluid (CSF). In conventional T1-weighted images, CSF appears dark due to its longer T1 relaxation time. By reducing T1 contrast, the CSF appears less dark, improving the visibility of bones. It allows for cortical bone and cortical bone water imaging ( Li et al. 2017 ) , resulting in better contrast between bone and surrounding tissues. Recently, PETRA has proved a valuable tool in musculoskeletal and orthopaedic imaging ( Kim et al. 2018 ) , since it is designed to provide high signal from tissues with very short T2 times, such as bone and tendons. Additionally, PETRA has been shown to reduce metal artefacts in dental imaging, although it can lead to poorer image quality ( Hilgenfeld et al. 2017 ) . While all MRI sequences sample data in k-space, PETRA’s uniqueness lies in how it optimises the acquisition and reconstruction process. PETRA differs from ZTE in how it starts signal acquisition; while ZTE achieves a true zero echo time (TE = 0), it has a gap in the centre of k-space due to receiver dead time, leading to image blurring. PETRA solves this gap issue by sampling the center of k-space with a Cartesian approach. This hybrid Cartesian - radial encoding of PETRA makes it also more efficient than UTE in bone imaging. PETRA encodes the very center of k-space with Cartesian encoding which prevents loss of short-T2* signals. UTE uses fully radial acquisition and is therefore less efficient in capturing short-T2 tissues, such as cortical bone and myelin. Additionally, the sampling strategy in PETRA scans can capture essential low-frequency components more efficiently than ZTE. This leads to better contrast and detail of the bony structures within the skull and minimisation of truncation artefacts such as Gibbs ringing. The radial acquisition pattern used reduces sensitivity to motion artefacts which also makes it a better choice for imaging moving organs like the heart and lungs ( Nozawa K 2019 ) . Other than its advantages in data handling, PETRA is available in Siemens scanners, which are widely used in clinical settings. These features collectively render PETRA a robust option for skull imaging, providing a well-balanced presentation