Read Scalable Ion Fluorescence Collection Using a Trap-Integrated Metalens by Hae Lim, Johannes E. Fröch, Christian M. Pluchar, Arka Majumdar, Sara L. Mouradian (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-23071.txt.
Introduction
Hae Lim and co-authors demonstrate a tiny lens built into an ion trap in 2025 for quantum computers. Trapped-ion machines read their qubits by catching the faint glow ions give off. Scaling up needs that light caught over a wide area without bulky optics.
Their metalens, a flat lens etched with nanoscale posts, sits on the back of the trap chip. Light passes through a slit and the lens lines it up for a sensor. A small slit caught under one percent of the light in tests. Widening the slit in simulation reached over three percent, on par with a good standard lens. Arrays of such zones could read many qubits in parallel.
Catalog record
| CREATOR | Hae Lim, Johannes E. Fröch, Christian M. Pluchar, Arka Majumdar, Sara L. Mouradian |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 21 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-23071
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Scalable Ion Fluorescence Collection Using a Trap-Integrated Metalens Hae Lim, Johannes E. Fröch, Christian M. Pluchar, Arka Majumdar, Sara L. Mouradian Abstract A scaled trapped-ion quantum computer will require efficient fluorescence collection across a large area. Here we propose and demonstrate a compact monolithically integrated system featuring a metalens fabricated on the backside of a surface ion trap. A 40 × 100 \times 100 μ \mu m aperture enables a simulated point-source collection efficiency of 0.91% and a measured point-source detection efficiency of 0.58%. Increasing the aperture area to 40 × 600 \times 600 μ \mu m boosts the simulated collection efficiency to 3.17%—comparable to that of a conventional objective with a numerical aperture of 0.35. Further improvements are possible by co-optimizing the electrode and aperture geometry. An undercut of the electrode substrate at the aperture ensures a large distance between the ion and dielectric substrate without compromising collection efficiency. The metalens directly collimates the collected fluorescence, eliminating the need for a high numerical aperture objective. An array of such readout zones will offer a compact, scalable solution for high-fidelity parallel readout in next-generation trapped-ion quantum processors. Quantum computers capable of demonstrating practical quantum advantage are projected to require hundreds of logical qubits Lekitsch et al. 2017 ; Reiher et al. 2017 , corresponding to millions of physical qubits with current error correction codes Low et al. 2020 . Trapped ions are a leading platform for quantum computation Bruzewicz et al. 2019 ; Png et al. 2022 ; Schwerdt et al. 2024 , but even the largest platforms Chen et al. 2024a ; DeCross et al. 2025 are currently limited to tens of ions. It is thus necessary to build systems that support scaling to millions of physical qubits while preserving high fidelity initialization, gate execution, and state discrimination. Here, we consider the quantum charge coupled device (QCCD) architecture Kielpinski et al. 2002 where millions of ions will be trapped in short linear chains and shuttled between initialization, control, and readout zones on a cm-scale chip. In particular, we focus on achieving high fidelity, fast state discrimination of trapped-ion qubits which relies on efficient fluorescence detection. Achieving scaled, high-fidelity state discrimination thus necessitates the development of advanced optical systems capable of high collection efficiency and uniform performance across multiple readout zones on a cm-sale device. Currently, most trapped-ion quantum computing demonstrations use a single objective to collect ion fluorescence as depicted in Fig. 1 (a). While it may be possible to design an objective that provides high collection efficiency over a cm-scale field of view, such as the objectives used for photolithography Zheng et al. 2021 , this is likely to be bulky and difficult to integrate with the full trapped-ion apparatus. Thankfully, high numerical aperture (NA) readout is only necessary in dedicated readout zones in a QCCD architecture,, and not continuously across the chip as in a conventional imaging system. Previous works have exploited this to create dedicated detection zones with diffractive mirrors Ghadimi et al. 2017 ; Connell et al. 2021 , detectors Todaro et al. 2021 ; Reens et al. 2022 ; Setzer et al. 2021 or collection-optimized grating couplers Knollmann et al. 2024 ; Smedley et al. 2025 directly integrated with the surface ion trap electrodes, achieving collection efficiencies of a few percent. Here, we take a different approach and design a system with small high-NA lenses directly integrated with the readout zones of a surface ion trap, as pictured in Fig. 1 (b). These integrated lenses collimate the ion fluorescence at each zone. This system can be paired with a focusing system and detector for state detection. Our device decouples the field of view and NA of the system, enabling a readout area limited only by the number of readout zones and the size of the focusing system and detector. We design, fabricate, and test one unit cell of such a device, demonstrating that it provides the same collection efficiency as a conventional objective, but with an expanded field of view limited only by the size of the focusing system and detector. Figure 1: (a) Conventional objective-based optical system used to image trapped-ion fluorescence (not to scale). (b) Scalable fluorescence collection with collimating metalenses integrated at each readout zone (not to scale). Previous efforts have mechanically integrated lenses with surface ion traps Brady et al. 2011 ; Streed et al. 2011 ; Clark et al. 2014 . In contrast, our approach involves fabricating a lens, specifically a metalens, directly on the backside of the trap itself. Metalenses enable direct integration and provide a smaller footprint and lower volume than refractive lenses Engelberg and Levy 2020 ; Kuznetsov et al. 2024 ; Shen et al. 2021 ; Huang et al. 2019 . This class of diffractive optical elements consists of sub-wavelength scale scatterers. Each scatterer imparts a specific phase delay, based on its physical dimension Arbabi et al. 2015 . Thus, arbitrary phase profiles, such as a high-NA focusing profile Paniagua-Dominguez et al. 2018 , extended depth of focus Huang et al. 2020 , or polarization-multiplexed focusing Fröch et al. 2025 , can be implemented in a single layer of a dielectric material. A single metalens device can also be designed to have different functions at different wavelengths, which are necessary for the optical control of atomic qubits Park et al. 2024 . Moreover, metalens fabrication relies on standard cleanroom or foundry processes Yang et al. 2025 and can thus be integrated with high accuracy with respect to the trap. This delivers a single chip solution with both trap and optical elements, making post-fabrication alignment obsolete Hu et al. 2022 ; Hsu et al. 2022 ; Ropp et al. 2023 ; Holman et al. 2024 ; Chen et al. 2024b . Figure 2: (a) Cross-section view of the device (not to scale). (b) Top view of the device, showing the alignment and relative sizes of the aperture (black), undercut (red), and metalens (black). (c) Simulated collection efficiency and normalized y -radial trap frequency as function of aperture width. The yellow dashed line indicates the aperture width of the fabricated device. (d) Simulated collection efficiency and normalized y -radial trap frequency with the undercut as function of aperture length. The yellow dashed line indicates the aperture length of the fabricated device. We begin with a standard surface trap design Chiaverini et al. 2005 and modify it to enable fluorescence collection through the trap. This enables direct integration with fabrication-limited alignment tolerances and will be directly applicable to multi-wafer trap designs Wilpers et al. 2012 ; Ragg et al. 2019 ; Decaroli et al. 2021 which may be necessary in a large-scale architecture Nguyen et al. 2025 . To facilitate light collection, an aperture is patterned into the ground electrode, allowing a fraction of the ion’s fluorescence to pass through the trap and reach the integrated lens. This backside lens collimates the transmitted fluorescence, which is then relayed to a global focusing system and ultimately onto a detector. For our analysis, we assume the ion emits photons uniformly in all directions, though note that the actual collection efficiency would depend on the dipole orientation. We define the collection efficiency as the percentage of total emitted light that successfully