Read Enhanced beam transport via space charge mitigation in a multistage accelerator for fusion plasma diagnostics Journal: \NF by M. Nishiura, K. Nakamura, K. Ueda, A. Shimizu, H. Takubo, M. Kanda, T. Ido, M. Okamura (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-20948.txt.
Introduction
Nishiura and seven co-authors improve the beam used to probe hot fusion plasma in a 2025 paper. The probe fires heavy ions into the plasma to measure its electric potential, but the beam's own charge pushes it apart.
That spreading is worst for heavy ions such as gold, and it cuts the beam that reaches the machine. The team reshaped how voltage is shared across the beam's acceleration stages, which added a lens effect that holds the beam together. Computer models and tests on a real device on the Large Helical Device agreed. The beam current entering the accelerator rose two to three times, with no mechanical changes. Measurements could then reach denser plasmas with a clearer signal.
Catalog record
| CREATOR | M. Nishiura, K. Nakamura, K. Ueda, A. Shimizu, H. Takubo, M. Kanda, T. Ido, M. Okamura |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 27 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-20948
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Enhanced beam transport via space charge mitigation in a multistage accelerator for fusion plasma diagnostics Journal: \NF M. Nishiura, K. Nakamura, K. Ueda, A. Shimizu, H. Takubo, M. Kanda, T. Ido, M. Okamura Abstract Efficient transport of high-current negative ion beams is critical for accurate plasma potential diagnostics using heavy-ion beam probe (HIBP) systems in magnetically confined fusion plasmas. However, strong space-charge effects often degrade transport efficiency, particularly for heavy ions such as Au - . In this study, we demonstrate a substantial improvement in beam transport by introducing an electrostatic lens effect through optimized voltage allocation in a multistage acceleration system. Numerical simulations using IGUN, supported by experiments with the LHD-HIBP system, show that this approach effectively suppresses space-charge-induced beam divergence and loss. Without requiring mechanical modifications to the beamline, the optimized configuration enables a 2–3 fold increase in Au - beam current injected into the tandem accelerator. Consequently, plasma potential measurements were extended to higher-density plasmas, reaching line-averaged electron densities up to 1.75 × 10 19 1.75\times 10^{19} m -3 with improved signal-to-noise ratio. This technique offers a compact, practical, and highly effective solution for transporting high-current heavy-ion beams under space-charge-dominated conditions. Beyond its impact on plasma diagnostics, the method is broadly applicable to a wide range of accelerator systems, including those used in scientific and industrial applications where high-intensity beam transport is required. July 2025 Keywords : beam transport, space charge, multistage accelerator, heavy ion beam probe 1 Introduction Advancing fusion power generation requires the development of both plasma physics understanding and diagnostic instrumentation. Among various diagnostics, the heavy ion beam probe (HIBP) has been developed to measure plasma electric potential and its fluctuations, which are closely related to confinement performance through the radial electric field. In the Large Helical Device (LHD), a strong magnetic field of approximately 3 T necessitates the use of MeV-class heavy ion beams to access the plasma core. The LHD-HIBP system employs a tandem accelerator capable of applying a nominal terminal voltage of 3 MV to produce the Au + probe beams with energies up to 6 MeV. The primary beams are injected into the plasma, where collisions with electrons and ions ionize them to the secondary beams of Au 2+ . The resulting secondary beam passes through the plasma. An energy analyzer allows the evaluation of the plasma potential from the energy difference from the initial beam [ 1 , 2 ] . Zonal flows have been observed in CHS [ 3 ] , and potential fluctuations associated with GAMs and Alfvén eigenmodes have been reported in the T-10 and TJ-II tokamaks [ 4 ] . The HIBP system in the LHD has been successfully used for measurements of radial electric fields during impurity transport [ 1 ] , energetic particle-driven geodesic acoustic modes (EGAM) [ 5 ] , and particle transport studies [ 6 ] . In LHD deuterium experiments [ 7 ] , the threshold power for the formation of an electron internal transport barrier is lower in deuterium plasmas than in hydrogen plasmas, accompanied by a clear potential transition observed with HIBP [ 8 ] . To enhance the performance of the LHD-HIBP system, a plasma sputter-type negative ion source was developed to improve the injection beam current and has been successfully utilized for many years. Subsequently, to validate the ionization efficiency from Au - to Au + in a gas cell of the tandem accelerator, the relevant ionization cross sections were theoretically derived and evaluated both experimentally and theoretically. The measured conversion efficiencies were obtained with the theoretical predictions [ 9 , 10 ] . It was also clarified that the dominant ionization processes differ depending on the beam energy: in the keV range, electron impact ionization prevails, while in the MeV range, ionization due to collisions with protons and highly charged ions becomes dominant. This energy dependence of ionization mechanisms is a distinguishing feature of the LHD-HIBP system, setting it apart from conventional HIBPs used in smaller devices. In this study, we report the implementation of a new cesium sputter-type negative ion source that improves the signal-to-noise ratio (S/N) and enables the use of multiple sputtering targets. The ion source was first characterized on a test stand and then installed in the LHD-HIBP system. However, the beam current measured at the entrance of the tandem accelerator was significantly lower than that obtained on the test stand, indicating substantial beam losses along the low-energy beam transport line. These results highlight that simply increasing the extracted negative ion beam current is insufficient to improve the injected or transmitted beam current in the tandem accelerator. Therefore, it is essential to identify the cause of these transport losses and to develop a solution to mitigate them. To address this issue, we investigated the origin of the beam loss and developed a method to improve the transport efficiency on the injection side of the tandem accelerator. Specifically, an electrostatic lens effect was introduced by optimizing the electrode voltage allocation in the multistage accelerator tube. Both numerical simulations and beam transport experiments confirmed that this approach effectively mitigates beam divergence caused by space-charge effects, particularly for low-energy, high-current heavy ion beams. As a result, the negative ion beam current injected into the tandem accelerator was significantly increased without requiring any mechanical modifications to the beamline. Using the optimized beam transport configuration, plasma potential measurements in the LHD were successfully demonstrated. 2 HIBP system for plasma diagnostics in the LHD 2.1 Negative ion beam extraction on test stand The cesium sputter-type negative ion source (High Voltage Engineering, Model 860C Multi Sample Source) produces cesium ions by thermionic emission from a heated filament. These ions bombard a metal target, producing negative ions via sputtering. The source is equipped with a revolver-type holder capable of loading up to ten metal targets, each embedded with Au or Cu and used as a sputtering material. This ion source has previously demonstrated an Au - beam output of up to 290 \mu A at Brookhaven National Laboratory [ 11 ] . Prior to integration into the LHD-HIBP system, the beam extraction characteristics of the ion source were evaluated at a dedicated test stand. The distance from the extraction electrode of the ion source to the Faraday cup used for these measurements was 591 mm, matching the corresponding distance to FC0 in the LHD-HIBP system. Figure 1 shows the dependence of the extracted negative ion beam current on the extraction voltage for the Model 860C source. The Einzel lens located at the exit of the ion source was tuned to maximize the beam current measured at the Faraday cup. While a direct comparison with the previously used plasma sputter-type negative ion source [ 9 ] is not straightforward due to differences in beam energy and operational conditions, comparable performance was observed, with Au - and Cu - beam currents reaching approximately 65 \mu A and 135 \mu A, respectively. Following confirmation of stable operation and favorable beam extraction characteristics on the test stand, the negative ion source was installed on the tandem accelerator for implementation in the LHD-HIBP system. Figure 1: Comparison of negative ion beam currents between the old plasma sputter type and the new cesium sputter type