Measurements of enriched 155 Gd and 157 Gd converters with the NMX detector on the n_TOF EAR2 beam line at CERN
N. Zavaritskaya · 2025
Read Measurements of enriched 155 Gd and 157 Gd converters with the NMX detector on the n_TOF EAR2 beam line at CERN by N. Zavaritskaya (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-20756.txt.
Introduction
Pfeiffer and co-authors test enriched gadolinium converters for a neutron detector in a 2025 paper. The NMX instrument, bound for a new European neutron source, now uses natural gadolinium to catch neutrons. Enriched forms of two isotopes might catch more, so the team took a small prototype to a CERN beam line in 2024.
Three runs aimed the beam at natural and at each enriched sample. The enriched 157 form caught far more slow neutrons: at one key wavelength about 60 percent more than natural, though below what models promised. Fog from gamma rays and beam focus likely explain the gap. The team backs the upgrade.
Catalog record
| CREATOR | N. Zavaritskaya |
|---|---|
| YEAR | 2025 |
| COLLECTION | PAPERS |
| FORMAT | TXT |
| FILE SIZE | 26 KB |
| VERSION | 1.0 |
| LICENSE | http://creativecommons.org/licenses/by/4.0/ |
| RIGHTS | CC BY |
| SOURCE | arXiv |
Source: https://arxiv.org/abs/2507-20756
Browse the full library · About the Tower of Babel
Full text
The opening of the work, from the library's hosted text:
Measurements of enriched 155 Gd and 157 Gd converters with the NMX detector on the n_TOF EAR2 beam line at CERN N. Zavaritskaya Abstract The detectors for the NMX instrument at the European Spallation Source (ESS) in Lund use natural Gd as the neutron converter. In 2024, beam time was obtained at the neutron time-of flight experiment (n_TOF) at CERN to study the feasibility of an upgrade to enriched Gd. A 10 x 10 cm 2 prototype of the NMX detector was equipped with two enriched Gd samples ( 157 Gd and 155 Gd) that were attached with copper tape to the natural Gd cathode of the detector. Three sets of measurements were taken, with the beam focused on either the natural Gd, the 157 Gd, or the 155 Gd samples. Using the time-of-flight technique with the subsequent conversion of time-of-flight into energy, the resonant region between 1 eV and 200 eV of the 157 Gd and 155 Gd cross sections was studied. The peaks in the resonant region were clearly visible, having higher ADC values in the ADC spectrum. Additionally, the resonant peaks had a larger number of counts per energy bin. In the thermal neutron energy range, the count rate at the center of the beam was measured for natural Gd, 157 Gd, and 155 Gd. Enriched 157 Gd showed an efficiency that was between 60 − \-- 180 % \% higher, compared to natural Gd, for neutron wavelengths between 0.8 Å and 1.8 Å. The measured 60 % \% increase in efficiency at 1.8 Å is lower than expected from simulations (100 % \% ) and previous measurements with solid state detectors (80 % \% ). Gamma background detection, bad focusing, and saturation effects most likely explain this deviation. An upgrade of the natural Gd converter to enriched 157 Gd would thus lead to an efficiency increase of at least 60 % \% . The measurements presented in this paper are the first successful time-of-flight measurements with the NMX detector prototype and the ESS VMM readout. 1 Introduction The European Spallation Source (ESS) [ 1 ] in Lund, Sweden will become the world’s most intense thermal neutron source with a significantly higher brilliance than at existing reactor or spallation sources. For the 15 neutron instruments that will comprise the initial instrument suite at ESS [ 2 , 3 ] , efficient thermal neutron detectors are a critical component [ 4 ] . The scientific user program for the first group of five instruments is expected to start in spring 2027. The macromolecular single-crystal diffractometer NMX [ 3 ] belongs to this first group, and requires three 51.2 x 51.2 cm 2 detectors with at least reasonable detection efficiency (around 25 \% for cold neutrons in the center of the wavelength range from 1.8 to 10 Å ), sub-mm spatial resolution [ 5 ] and a good ( 0.1 ms) time resolution. The combination of solid neutron converters with micro pattern gaseous detectors (MPGDs) [ 6 , 7 ] is a promising option to achieve these requirements. Currently, the NMX detector consists of a natural gadolinium neutron converter mounted as cathode in a triple GEM detector [ 8 ] with a low material budget x/y strip readout. Since beam time at ESS will be a precious commodity, it is paramount to optimize the neutron detection efficiency and the signal to background ratio of the neutron detectors. To improve the neutron detection efficiency, an upgrade of the natural gadolinium converter to an enriched 157 Gd converter is being considered. The relative improvement in detection efficiency of two samples of enriched 155 Gd and 157 Gd compared to natural gadolinium has been measured during two dedicated beam times at the EAR2 beamline of the n \_ TOF experiment at CERN. In 2024, 39 hours were allocated to us from March 20th to March 22nd and 17 hours from October 24th to October 25th. 2 The NMX detector prototype For the measurements at n \_ TOF, a smaller 10 x 10 cm 2 prototype was used in lieu of the full-size 51.2 x 51.2 cm 2 detector (Figure 1a ). The conversion volume (or drift space) is 10 mm long, and a 25 \mu m gadolinium foil serves as cathode and neutron converter. A drift field of 700 V/cm was chosen to avoid electron attachment to electronegative impurities and the subsequent loss of primary ionization electrons, while keeping the drift velocity smaller than 2.0 cm/ \mu s at atmospheric pressure. The three GEM foils [ 9 ] in the detector are mounted at a distance of 2 mm from each other and powered with a resistor chain. The values of the resistors are stated in Figure 1b . The detector operates at an effective gain of about 5000, and is usually flushed with Ar/CO 2 70/30 mixture at 5 l/h at room temperature and atmospheric pressure. (a) Gd-GEM 10 cm x 10 cm prototype (b) Schematic view of Triple-GEM detector Figure 1 : Gd-GEM neutron detector A schematic drawing of the NMX detector is displayed in Figure 1b . The detector is operated in backwards mode. Neutrons traverse the low material budget detector readout and the three GEM foils, and then impinge on the natural Gd cathode. Natural Gd contains 14.8 \% 155 Gd and 15.7 \% 157 Gd. Both of these isotopes have a very high neutron capture cross section [ 10 ] . After the neutron capture, gadolinium releases prompt gamma particles with an energy of up to 9 MeV and conversion electrons with energies ranging from 29 keV to 250 keV. The signals resulting from these conversion electrons are used to determine the position of the neutron impact on the cathode with the help of the uTPC method [ 11 , 12 ] . The strip pitch of the x/y readout is 400 \mu m. There are 256 strips each in the x - and y -directions, which are read out with two RD51 VMM3a hybrids each in the x -and y -directions (figure 1a ). Two VMM3a ASICs [ 13 , 14 ] with 64 channels per chip are mounted on a RD51 VMM3a hybrid [ 15 , 16 ] , resulting in 128 channels per hybrid. With this small prototype, a detection efficiency of 11.8 \% for neutrons with a wavelength of 2 Å [ 12 ] was measured at IFE [ 17 ] in 2016. For that measurement, the detector used a traditional x/y strip readout that contained an FR4 base [ 18 ] . We replaced this with a low material budget readout that uses a 100 \mu m thick Kapton foil to reduce the neutron scattering from \sim 20~\% to \sim 5~\% . For a Gd-GEM detector with low material budget readout, as used in the n \_ TOF measurements, the detection efficiency at 2.4 Å was simulated with Geant4 10.1 [ 19 ] to be around 15 \% with a threshold of 0 keV. 3 The experimental setup The experimental setup at the n_TOF EAR2 beam line is shown in Figure 2a . The n_TOF experiment uses proton bunches that are first extracted from the PS accelerator, and subsequently hit a spallation