A continuous-wave vacuum ultraviolet laser for the nuclear clock

Qi Xiao, Gleb Penyazkov, Xiangliang Li, Beichen Huang, Wenhao Bu, Juanlang Shi, Haoyu Shi, Tangyin Liao, Gaowei Yan, Haochen Tian, Yixuan Li, Jiatong Li, Bingkun Lu, Li You, Yige Lin, Yuxiang Mo, Shiqian Ding · 2025

Read A continuous-wave vacuum ultraviolet laser for the nuclear clock by Qi Xiao, Gleb Penyazkov, Xiangliang Li, Beichen Huang, Wenhao Bu, Juanlang Shi, Haoyu Shi, Tangyin Liao, Gaowei Yan, Haochen Tian, Yixuan Li, Jiatong Li, Bingkun Lu, Li You, Yige Lin, Yuxiang Mo, Shiqian Ding (2025) in the Tower of Babel, a free online library of public-domain works preserved in clean, searchable text. No sign-up. The full text is served as a plain-text file at a predictable URL, where text is present: https://antarctic-labs.com/tower-of-babel/arxiv-2507-19449.txt.

Introduction

Qi Xiao and co-authors demonstrate the first steady vacuum ultraviolet laser for a nuclear clock in a paper from 2025. The clock would tick on a jump inside the thorium-229 nucleus. That jump needs light at about 148 nanometers, deep in the ultraviolet.

Pulsed lasers had reached the line, but a steady, narrow beam is needed to control nuclei. The team made the light by mixing waves in cadmium vapor. The source gives a steady beam with a very narrow line width. Its color can be tuned across a broad range. Power is small but enough for spectroscopy. A steady source brings a working nuclear clock closer.

Catalog record

CREATORQi Xiao, Gleb Penyazkov, Xiangliang Li, Beichen Huang, Wenhao Bu, Juanlang Shi, Haoyu Shi, Tangyin Liao, Gaowei Yan, Haochen Tian, Yixuan Li, Jiatong Li, Bingkun Lu, Li You, Yige Lin, Yuxiang Mo, Shiqian Ding
YEAR2025
COLLECTIONPAPERS
FORMATTXT
FILE SIZE28 KB
VERSION1.0
LICENSEhttp://creativecommons.org/licenses/by/4.0/
RIGHTSCC BY
SOURCEarXiv

Source: https://arxiv.org/abs/2507-19449

Browse the full library · About the Tower of Babel

Full text

The opening of the work, from the library's hosted text:

A continuous-wave vacuum ultraviolet laser for the nuclear clock Qi Xiao, Gleb Penyazkov, Xiangliang Li, Beichen Huang, Wenhao Bu, Juanlang Shi, Haoyu Shi, Tangyin Liao, Gaowei Yan, Haochen Tian, Yixuan Li, Jiatong Li, Bingkun Lu, Li You, Yige Lin, Yuxiang Mo, Shiqian Ding Abstract The exceptionally low-energy isomeric transition in 229 Th at around 148.4 nm offers a unique opportunity for coherent nuclear control and the realisation of a nuclear clock. Recent advances, most notably the incorporation of large ensembles of 229 Th nuclei in transparent crystals and the development of pulsed vacuum‑ultraviolet (VUV) lasers, have enabled initial laser spectroscopy of this transition. However, the lack of an intense, narrow-linewidth VUV laser has precluded coherent nuclear manipulation. Here we introduce and demonstrate the first continuous-wave laser at 148.4 nm, generated via four-wave mixing (FWM) in cadmium vapor. The source delivers 100 nW of power with a linewidth well below 100 Hz and supports broad wavelength tunability. This represents a five-orders-of-magnitude improvement in linewidth over all previous single-frequency lasers below 190 nm, marking a major advance in laser technology. We develop a spatially resolved homodyne technique to place a stringent upper bound on the phase noise induced by the FWM process and demonstrate sub-hertz linewidth capability. These results eliminate the final technical hurdle to a 229 Th‑based nuclear clock, opening new directions in quantum metrology, nuclear quantum optics and precision tests of the Standard Model. More broadly, they establish a widely tunable, ultranarrow-linewidth laser platform for applications across quantum information science, condensed matter physics, and high-resolution VUV spectroscopy. The coherent excitation of nuclear transitions has long remained elusive due to the vast energy mismatch between nuclear states and available laser sources. A striking exception is the uniquely low-energy isomeric transition in 229 Th at 8.4 eV ( \sim 148.4 nm) 1 ; 2 ; 3 ; 4 ; 5 ; 6 ; 7 ; 8 ; 9 ; 10 , which combines optical accessibility, as finally enabled in this work, with extraordinary insensitivity to external perturbations, owing to the small nuclear electric and magnetic moments. These properties provide a foundation for a revolutionary nuclear clock 11 with unprecedented precision 12 , and offer a powerful probe for testing physics beyond the Standard Model 13 ; 14 ; 15 . Recent breakthroughs using 229 Th-doped crystals 11 ; 14 ; 16 ; 6 ; 17 have enabled laser spectroscopy of the isomer 7 ; 8 ; 9 ; 18 ; 19 ; 20 ; 21 using pulsed vacuum‑ultraviolet (VUV) sources, including nanosecond four-wave mixing 22 ; 23 and high-harmonic generation frequency combs 24 . These systems allow simultaneous interrogation of up to 10^{15} nuclei, enabling fluorescence detection even with weak laser fields that excite only a small fraction of the ensemble. However, existing pulsed lasers suffer from either broad linewidths (GHz-scale) 22 ; 23 or extreme power dilution across millions of comb teeth, with only 1 nW residing in the desired tooth 24 . As a result, the achievable power spectral density remains far too low for coherent control. This limitation is even more acute in ion-trap platforms 11 ; 12 ; 25 ; 26 ; 27 ; 28 ; 29 , where only a small number of 229 Th ions are available. While these systems offer exceptional isolation, ultralong interrogation times, and the full toolbox of quantum manipulation 30 ; 31 , including optical nuclear-qubit encoding and entanglement protocols, laser excitation of the nucleus has yet to be demonstrated. The lack of sufficient laser power spectral density remains the central bottleneck impeding progress toward ultimate nuclear clock performance 12 and nuclear-based quantum information processing. Fig. 1: Generation of a CW VUV laser with narrow linewidth. a , Energy-level diagram for the resonance-enhanced FWM process in cadmium vapor. b , Schematic of the experimental setup. The 375 nm and 710 nm beams are combined and focused into two cadmium ovens. The resulting VUV beams are separated from the fundamental beams using Brewster-angle MgF 2 prisms and interfered on a CCD camera. SHG: second-harmonic generation. c , Spatial mode profile of the generated 148.4 nm beam (left panel) and interference pattern (right panel) recorded with a 10 s exposure time. Black curves show 1D projections along the horizontal and vertical axes. d , Both Ti:sapphire lasers are frequency-stabilised to a shared ultrastable ULE cavity to compress their linewidths. e , Linewidths of the 750 nm and 710 nm lasers are probed via beat notes with an optical frequency comb referenced to a ULE-cavity-stabilised 1550 nm laser. Despite its central importance, continuous-wave (CW) laser radiation at 148.4 nm, concentrating all power into a narrow linewidth to boost power spectral density over pulsed sources, has remained a formidable challenge 10 . Narrow-linewidth CW VUV sources are also in demand across other research areas, including high-resolution VUV spectroscopy, angle-resolved photoemission spectroscopy (ARPES) 32 in condensed matter systems, and direct laser cooling of Al + ions for state-of-the-art optical clocks 31 ; 33 . However, standard phase-matched frequency conversion in this spectral region is precluded by strong absorption and dispersion in nonlinear crystals 34 , while quasi-phase matching in periodically poled VUV-transparent nonlinear crystals demands domain periods of microns or less 35 that remain beyond current fabrication capabilities 36 . Four-wave mixing (FWM) in atomic vapors 37 ; 38 ; 39 offers an alternative approach, exploiting third-order nonlinearities to generate sum-frequency radiation. This method has enabled CW generation of the hydrogen Lyman- \alpha line in mercury 38 , but with estimated linewidths at 10 MHz 40 , which are far too broad for nuclear clock applications. Here we report, to our knowledge, the first CW laser at the 229 Th isomeric transition wavelength 41 , realised via resonance-enhanced FWM in cadmium vapor. This laser delivers 100 nW of CW power at 148.4 nm with a linewidth well below 100 Hz, and offers continuous tunability across at least 140 nm to 175 nm using cadmium 41 , with broader coverage feasible using other nonlinear media. This represents several orders of magnitude improvement in power spectral density over existing VUV sources 22 ; 24 ; 23 below 190 nm 42 , providing the critical enabling tool for coherent manipulation of the 229 Th nucleus. We further show that the FWM process preserves sub-hertz coherence, with an upper-bound fractional frequency instability well below 10^{-16} . This resolves key concerns about whether GHz-scale Doppler and collisional broadening in hot vapor media would degrade phase coherence in CW nonlinear frequency conversion 43 . The phase noise is measured using a novel spatially resolved homodyne technique that operates with only sub-nanowatt optical power, which may become broadly useful for measuring optical phase in power-limited regimes. Finally, our measured power agrees well with predictions from a theoretical model 41 that combines FWM theory with ab initio atomic structure calculations 44 , providing predictive power for future source design without relying on extensive experimental iteration. Together, these results establish a robust and versatile CW laser platform with ultranarrow linewidth and wide tunability in the VUV, opening new frontiers in nuclear quantum optics, quantum metrology, condensed matter physics, quantum information processing, and chemical dynamics. VUV generation protocol We generate the 148.4 nm radiation via resonance-enhanced FWM

Read the complete text